Sign in

REFERENCE, Auburn, WA 98092

Not for sale · Owner in Washington

Lots near here →

0 sf · -9223372036854775808% outside sensitive areas

0 sf · 0.0 ac
Width ≈ 310 ft · Depth ≈ 219 ft
Outside sensitive areas about 70,800 sf
Width and depth are estimated.
County
Pierce County
Parcel ID
0520061056
Assessed land value
$0
Assessed building value
$0
Legal
Section 06 Township 20 Range 05 Quarter 13 : LAND ASSESSED WITH UNITS IN FOXWOOD AT LAKELAND CONDO PH VI 900400- DESC AS COM AT NW COR L 3 BLA 99-01-26-0552 TH S 11 DEG 28 MIN 56 SEC E 100.05 FT TO POB TH N 76 DEG 46 MIN 29 SEC E 72.46 FT TH S 70 DEG 41

Values are from the county assessor.

Jurisdiction
Auburn
Zone
LAKELAND HILLS SOUTH PUD · Planned Unit Development District (PUD) - Lakeland Hills South →

Your lot

Lot area
0 sf
Net area
0 sf (lot area minus wetland, flood, steep slope)
Frontage
227 ft
Lot width
≈ 310 ft (estimated)
Lot depth
≈ 219 ft (estimated)

✔ You can build (by right)

1 unit
Senior housing and servicesACC 18.76.040(A)(1)(i)
⚠ Needs to check:
  • Lot area: Housing concepts of all types limited only by the density allowed in the official Lakeland plan map.ACC 18.76.040(A)(1); 18.76.050(B)
  • Planning area designation of the lot on the official Lakeland plan map is seniorACC 18.76.030(J); 18.76.040(A)(1)
2 units
Senior housing and servicesACC 18.76.040(A)(1)(i)
⚠ Needs to check:
  • Lot area: Housing concepts of all types limited only by the density allowed in the official Lakeland plan map.ACC 18.76.040(A)(1); 18.76.050(B)
  • Planning area designation of the lot on the official Lakeland plan map is seniorACC 18.76.030(J); 18.76.040(A)(1)
3 units
Senior housing and servicesACC 18.76.040(A)(1)(i)
⚠ Needs to check:
  • Lot area: Housing concepts of all types limited only by the density allowed in the official Lakeland plan map.ACC 18.76.040(A)(1); 18.76.050(B)
  • Planning area designation of the lot on the official Lakeland plan map is seniorACC 18.76.030(J); 18.76.040(A)(1)
4+ units
Senior housing and servicesACC 18.76.040(A)(1)(i)
⚠ Needs to check:
  • Lot area: Housing concepts of all types limited only by the density allowed in the official Lakeland plan map.ACC 18.76.040(A)(1); 18.76.050(B)
  • Planning area designation of the lot on the official Lakeland plan map is seniorACC 18.76.030(J); 18.76.040(A)(1)
ADU
ADU with Senior housing and servicesACC 18.32.010(A); 18.76.040(A)(1)(c)
⚠ Needs to check:
  • Lot area: Housing concepts of all types limited only by the density allowed in the official Lakeland plan map.ACC 18.76.040(A)(1); 18.76.050(B)
  • Planning area designation of the lot on the official Lakeland plan map is seniorACC 18.76.030(J); 18.76.040(A)(1)

Dividing the lot

Short subdivision
✗ Cannot be divided into 2 lotsACC 17.09.060(A); 18.76.110(A)
✗ Net area 0 sf < 4,585 sf required (short 4,585 sf)ACC 18.76.050(B)-(C)
✗ New lot area 0 sf < 1,800 sf required (short 1,800 sf)ACC 18.76.060(A)(1)(a); ACC 18.76.060(A)(2)(a); ACC 18.76.060(A)(3)(a); ACC 18.76.060(B)(1)(a); ACC 18.76.060(B)(2)(a); ACC 18.76.060(B)(3)(a); ACC 18.76.060(C)(1)(a)
Subdivision
✗ Cannot be divided into 10 lotsACC 17.10.030; 18.76.020(B)-(C); 18.76.110(A)
✗ Net area 0 sf < 22,926 sf required (short 22,926 sf)ACC 18.76.050(B)-(C)
✗ New lot area 0 sf < 1,800 sf required (short 1,800 sf)ACC 18.76.060(A)(1)(a); ACC 18.76.060(A)(2)(a); ACC 18.76.060(A)(3)(a); ACC 18.76.060(B)(1)(a); ACC 18.76.060(B)(2)(a); ACC 18.76.060(B)(3)(a); ACC 18.76.060(C)(1)(a)

Counted: only lots that face an existing road.
Not checked: lot shape, and whether the lot was divided in the last 5 years.

Frontage (lot edge within 50 ft of a road)
62nd St SElocal road161 ft
63rd St SElocal road66 ft
Outside sensitive areas about 70,800 sf (wetland, flood, mapped stream buffer and slope 40% or more are taken off)
The largest rectangle that fits outside the sensitive areas. Setbacks and review areas are not taken off.
Easy to build: standard foundation, little grading.
Some extra cost: stepped foundation, steeper driveway.
Estimated from public maps. A site study and the permit review set the final area.

Source: USGS 3DEP bare-earth elevation (lidar), slope on a 3 m grid.
Check it on the WA DNR Lidar Portal ↗.

1. Soil on the lot

Foundation somewhat limited · Rain water very limited
Foundation very limited · Rain water very limited

2. What it means for a house

Foundation
USDA soil rating for a house foundation · Soil A, 81% of the land outside sensitive areas
1
USDA rating
Not limitedSomewhat limitedVery limited

USDA rates every soil on 3 levels, from best to worst.

2
What "somewhat limited" means

The soil is fair for this use. The limits can be overcome or made smaller with special planning, design or building. Expect fair performance and some upkeep.

USDA text
"Somewhat limited" indicates that the soil has features that are moderately favorable for the specified use. The limitations can be overcome or minimized by special planning, design, or installation. Fair performance and moderate maintenance can be expected.
3
How USDA rates it

The use: A house of 3 stories or less, with no basement. It sits on concrete footings, about 2 ft deep.

The test: USDA checks soil features for this use, like flooding, ground water and slope. Each feature that limits the use gets a score from 0.01 to 1.00. The worst score sets the rating: 1.00 is very limited, a lower score is somewhat limited, no score is not limited.

USDA text
Dwellings are single-family houses of three stories or less. For dwellings without basements, the foundation is assumed to consist of spread footings of reinforced concrete built on undisturbed soil at a depth of 2 feet or at the depth of maximum frost penetration, whichever is deeper.
All features and their limits →
4
What USDA found here: 2 limiting features · worst 0.20 → somewhat limited
  • Depth to saturated zoneNo limitWorst0.20Ground water is close to the surface. The soil drains slowly and can get soggy in heavy rain.
    USDA text
    Soils with shallow depth to a water table maybe difficult to reclaim and revegetated. These areas are slow to drain and can become waterlogged and boggy during periods of heavy precipitation.
  • SlopeNo limitWorst0.16Steep ground makes it hard for heavy machines to work.
    USDA text
    Steep slopes impede trafficability of heavy machinery and reclamation of borrow sites.
Rain water
USDA soil rating for soaking up rain water · Soils A and B, 100% of the land outside sensitive areas
1
USDA rating
Not limitedSomewhat limitedVery limited

USDA rates every soil on 3 levels, from best to worst.

2
What "very limited" means

The soil has one or more features that are bad for this use. They usually cannot be fixed without major soil work, a special design, or costly building methods. Expect poor performance and high upkeep.

USDA text
"Very limited" indicates that the soil has one or more features that are unfavorable for the specified system. The limitations generally cannot be overcome without major soil reclamation, special design, or expensive installation procedures. Poor performance and high maintenance can be expected.
3
How USDA rates it

The use: A shallow system that lets rain water soak into the ground, like a rain garden, a swale or porous paving. It holds 1 inch of rain, and the water should soak in within 24 to 48 hours.

The test: USDA checks soil features for this use, like flooding, ground water and slope. Each feature that limits the use gets a score from 0.01 to 1.00. The worst score sets the rating: 1.00 is very limited, a lower score is somewhat limited, no score is not limited.

USDA text
Shallow Infiltration Systems are a set of Best Management Practices for stormwater management. These systems include pervious pavement, buffer strips, filter strips, and vegetated swales. … The fundamental function of these systems is to hold the runoff generated from an area during a one inch rainfall event. … The water should infiltrate into the surrounding soil in 24 to 48 hours.
All features and their limits →
4
What USDA found here: 4 limiting features · worst 1.00 → very limited
  • WetnessNo limitWorst1.00Ground water comes close to the surface in the wet season.
    USDA text
    Soils having a high seasonal water table are limited for shallow infiltration systems.
  • SlopeNo limitWorst0.47Sloping ground is harder for machines and needs a changed design. Added water can make the slope slide.
    USDA text
    Soils that are sloping are limited in terms of the stormwater management systems that can be installed. Sloping soils are more difficult to for equipment usage. excessive slope may also be a trigger for mass movement when additional water is added to a part of the landscape.
  • Vegetation establishmentNo limitWorst0.44After digging, plants are harder to grow back. Better topsoil or soil amendments may be needed.
    USDA text
    Material rated fair can be vegetated and stabilized by modifying one or more properties. Topdressing with better material or applications of soil amendments may be necessary for satisfactory performance.
  • Adsorptive capacityNo limitWorst0.20The soil under the system can hold back only a little of the harmful material in rain water. This reason can make the rating somewhat limited, never very limited.
    USDA text
    Soils having low adsorption lack the ability to attenuate potentially harmful material.

Source: USDA soil survey (SSURGO). It maps soil at about 1 inch = 1/4 mile, so a soil line can be off by 100 ft or more. For screening only.
USDA: "Onsite investigation may be needed to validate these interpretations and to confirm the identity of the soil on a given site."
Not checked: septic, liquefaction.

Sewer

Inside UGA
yes
Nearest public main
on the lot
Provider
City of Auburn ↗

Source: WA Urban Growth Areas; city, county and sewer district sewer maps.
The sewer maps have gaps. A main can be there but not on the map. The sewer district decides.

Water

Water system
BONNEY LAKE WATER DEPARTMENT CITY
Phone
(253) 261-7404

Source: WA Department of Health service areas. The area shows who serves the lot, not where the pipe is. Ask the water system for the distance to the main and the cost.