Sign in

R4A · Residential High Density 4A

Anacortes, WA · AMC 19.40.030(H) · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family
Home✓ ADU✓1
Home✓ ADU✓1
Home✓ ADU✓1
Home✓ ADU✓1
—
Manufactured home
Home✓2 ADU✓3
————
Single-family, small lot
Home✓4 ADU✓5
————
Duplex—
Home✓ ADU✓1
—
Home✓ ADU✓1
—
Triplex——
Home✓ ADU✓1
Home✓ ADU✓1
—
Townhouse——
Home✓ ADU✓1
Home✓ ADU✓1
—
Cottage housing——
Home✓ ADU—
Home✓ ADU—
—
Multifamily———
Home✓ ADU✓1
—
Multifamily, restricted———
Home✓ ADU✓1
—
Adult family home————
Home✓ ADU✓1
Permanent supportive housing————
Home✓ ADU✓1
Transitional housing————
Home✓ ADU✓1
Co-living housing————
Home✓ ADU✓1

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set AMC 19.42.020
Three to 12 cottage structures may make up a cluster. There is no limit on the number of clusters, provided all other standards are met. AMC 19.43.040(C)(3)(b)
for Cottage housing (4+ units)
Minimum lot sizeNot set AMC 19.42.020
3,000 sq ft AMC 19.42.020
for Single-family (1 unit); Manufactured home (1 unit)2; Single-family, small lot (1 unit)4; Duplex (2 units); Adult family home (group living)
3,000 × main dwelling units on the lot sq ft AMC 19.42.020; 19.43.020(C)
for Single-family (2, 3, 4+ units)
3,000 × (main dwelling units on the lot ÷ 2, rounded up) sq ft AMC 19.42.020; 19.43.050(C)
for Duplex (4+ units)
Permanent supportive housing and transitional housing are subject to the same development standards as the “household living” dwelling type/form proposed (e.g., single-family, duplex, triplex, multifamily, etc.) in the respective zone, consistent with RCW 36.130.020, except for AMC Chapter 19.64, Parking, and except for AMC 19.62.040, Internal open space. AMC 19.43.160(C)(1)
for Permanent supportive housing (group living); Transitional housing (group living)
Maximum densityNot set AMC 19.42.020
Permanent supportive housing and transitional housing are subject to the same development standards as the “household living” dwelling type/form proposed (e.g., single-family, duplex, triplex, multifamily, etc.) in the respective zone, consistent with RCW 36.130.020, except for AMC Chapter 19.64, Parking, and except for AMC 19.62.040, Internal open space. AMC 19.43.160(C)(1)
for Permanent supportive housing (group living); Transitional housing (group living)
Maximum residentsNot set AMC 19.42.020
  • 6 persons6 AMC 19.43.120(A)
  • 8 persons7 AMC 19.43.120(A)
for Adult family home (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft AMC 19.42.020
Side setback5 ft AMC 19.42.020
Street side setback10 ft AMC 19.42.020
Rear setback10 ft AMC 19.42.020
Building separationNot set AMC 19.42.020
10 ft AMC 19.43.040(C)(4)(b)
for Cottage housing (3, 4+ units)
Maximum height35 ft AMC 19.42.020
25 ft AMC 19.43.040(C)(5)(a)
for Cottage housing (3, 4+ units)
Maximum lot coverage60% AMC 19.42.020
  • 75%8 AMC 19.43.080(C)(5)(a)
  • 60%9 AMC 19.42.020
for Multifamily (4+ units); Multifamily, restricted (4+ units)
Minimum parking
  • 0.75 spaces per unit10 AMC 19.64.040
  • 1 space per unit11 AMC 19.64.040
  • 1.4 spaces per unit12 AMC 19.64.040
  • 1.6 spaces per unit13 AMC 19.64.040
2 spaces per unit AMC 19.64.040
for Single-family (1, 2, 3, 4+ units); Manufactured home (1 unit)2; Adult family home (group living)
1 space per unit AMC 19.64.040
for Single-family, small lot (1 unit)4
1.5 spaces per unit AMC 19.64.040
for Cottage housing (3, 4+ units)
  • 0.75 spaces per unit10 AMC 19.64.040
  • 1 × 0.75 spaces per unit11 AMC 19.64.040
  • 1.4 × 0.75 spaces per unit12 AMC 19.64.040
  • 1.6 × 0.75 spaces per unit13 AMC 19.64.040
for Multifamily, restricted (4+ units)
Per the applicable household living dwelling type except when applicant submits a parking study that demonstrates a reduction is warranted due to site and project-specific characteristic. AMC 19.64.040
for Permanent supportive housing (group living); Transitional housing (group living)
  • 0 spaces per sleeping unit14 AMC 19.64.040
  • 0.25 spaces per sleeping unit15 AMC 19.64.040
for Co-living housing (group living)
Maximum unit sizeNot set AMC 19.42.020
1,200 sq ft AMC 19.43.040(C)(6)
for Cottage housing (3, 4+ units)
Permanent supportive housing and transitional housing are subject to the same development standards as the “household living” dwelling type/form proposed (e.g., single-family, duplex, triplex, multifamily, etc.) in the respective zone, consistent with RCW 36.130.020, except for AMC Chapter 19.64, Parking, and except for AMC 19.62.040, Internal open space. AMC 19.43.160(C)(1)
for Permanent supportive housing (group living); Transitional housing (group living)
Minimum open space20% AMC 19.42.020
15% AMC 19.43.070(C)(4)(b)
for Townhouse (3, 4+ units)
  • 15%8 AMC 19.43.080(C)(5)(b)
  • 20%9 AMC 19.42.020
for Multifamily (4+ units); Multifamily, restricted (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units AMC 19.47.030(C)(1)
Minimum lot size3,000 sq ft AMC 19.47.030(C)(3)(b); 19.42.020
3,000 × main dwelling units on the lot sq ft AMC 19.47.030(C)(3)(b); 19.42.020; 19.43.020(C)
for Single-family (2, 3, 4+ units)1
Not set AMC 19.47.030(C)(3)(b); 19.42.020
for Triplex (3, 4+ units)1; Townhouse (3, 4+ units)1; Multifamily (4+ units)1; Multifamily, restricted (4+ units)1; Co-living housing (group living)1

Building

StandardValueExceptions
Front setback10 ft AMC 19.47.030(C)(3)(d); 19.42.020
Side setback
  • 0 ft16 AMC 19.47.030(C)(3)(d)(i)
  • 5 ft17 AMC 19.47.030(C)(3)(d); 19.42.020
Rear setback
  • 0 ft16 AMC 19.47.030(C)(3)(d)(i)
  • 10 ft17 AMC 19.47.030(C)(3)(d); 19.42.020
Maximum height
  • 25 ft18 AMC 19.47.030(C)(3)(c)
  • 35 ft19 AMC 19.47.030(C)(3)(c); 19.42.020
Minimum parking1 space per unit AMC 19.47.030(C)(6); 19.64.040
Maximum unit size1,000 sq ft AMC 19.47.030(C)(3)(a)
Attached to the main houseNot required AMC 19.47.030(C)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision AMC 19.20.030; 19.32.050(A)(1) A up to 9 AMC 19.12.020 —
Minimum lot size
3,000 sq ft AMC 19.42.020; 19.42.080
Minimum lot width
  • 25 ft20 AMC 19.42.020; 19.42.090(B)
  • 30 ft21 AMC 19.42.020; 19.42.090(B)
Minimum lot depth
Not set AMC 19.42.020
Minimum frontage
Not set AMC 19.42.020
Maximum units per lot
Not set AMC 19.42.020
Long subdivision AMC 19.20.030; 19.32.050(B)(1) H 10 or more AMC 19.12.020 —
Minimum lot size
3,000 sq ft AMC 19.42.020; 19.42.080
Minimum lot width
  • 25 ft20 AMC 19.42.020; 19.42.090(B)
  • 30 ft21 AMC 19.42.020; 19.42.090(B)
Minimum lot depth
Not set AMC 19.42.020
Minimum frontage
Not set AMC 19.42.020
Maximum units per lot
Not set AMC 19.42.020
Unit lot subdivision AMC 19.32.050(D)(1); 19.20.030Only for: Duplex, Triplex, Cottage housing, Townhouse A up to 9 AMC 19.32.050(D)(1); 19.12.020 —
Minimum lot size
Not set AMC 19.32.050(D)(3)
Minimum lot width
Not set AMC 19.42.090(C)
Minimum lot depth
Not set AMC 19.32.050(D)(3)
Minimum frontage
Not set AMC 19.32.050(D)(3)
Maximum units per lot
Not set AMC 19.32.050(D)(3)
Unit lot subdivision AMC 19.32.050(D)(1); 19.20.030Only for: Duplex, Triplex, Cottage housing, Townhouse H 10 or more AMC 19.32.050(D)(1); 19.12.020 —
Minimum lot size
Not set AMC 19.32.050(D)(3)
Minimum lot width
Not set AMC 19.42.090(C)
Minimum lot depth
Not set AMC 19.32.050(D)(3)
Minimum frontage
Not set AMC 19.32.050(D)(3)
Maximum units per lot
Not set AMC 19.32.050(D)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The property is served by public sewer
  2. The manufactured home is new
  3. All of these are true:
    • The manufactured home is new
    • The property is served by public sewer
  4. Lot area minus critical areas and buffers is less than 5,000 sf
  5. All of these are true:
    • Lot area minus critical areas and buffers is less than 5,000 sf
    • The property is served by public sewer
  6. None of these is true:
    • The Department of Social and Health Services approved up to eight adults under RCW 70.128.066
  7. The Department of Social and Health Services approved up to eight adults under RCW 70.128.066
  8. At least 50 percent of all required parking is located within and/or below the structure
  9. None of these is true:
    • At least 50 percent of all required parking is located within and/or below the structure
  10. The units are affordable housing (includes permanent supportive housing and transitional housing)
  11. All of these are true:
    • Bedrooms in one unit is less than 2
    None of these is true:
    • The units are affordable housing (includes permanent supportive housing and transitional housing)
  12. All of these are true:
    • Bedrooms in one unit is at least 2
    • Bedrooms in one unit is less than 3
    None of these is true:
    • The units are affordable housing (includes permanent supportive housing and transitional housing)
  13. All of these are true:
    • Bedrooms in one unit is at least 3
    None of these is true:
    • The units are affordable housing (includes permanent supportive housing and transitional housing)
  14. Located within one-half mile walking distance of a major transit stop
  15. None of these is true:
    • Located within one-half mile walking distance of a major transit stop
  16. All of these are true:
    • The ADU is a detached accessory dwelling unit
    • The lot line being measured (side or rear) abuts a public alley that the city does not routinely plow for snow
  17. Not all of these are true:
    • The ADU is a detached accessory dwelling unit
    • The lot line being measured (side or rear) abuts a public alley that the city does not routinely plow for snow
  18. The ADU is a detached accessory dwelling unit
  19. None of these is true:
    • The ADU is a detached accessory dwelling unit
  20. The lot has alley access
  21. None of these is true:
    • The lot has alley access