RMHC · R-MHC Manufactured/Mobile Home Community Zone
Auburn, WA · ACC 18.09 · Official code
By right: 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Manufactured/mobile home community | — | — | — | Home✓ ADU✓ | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,300 × main dwelling units on the lot sq ft ACC 18.09.030(E) | |
| Minimum density | 8 units per acre ACC 18.09.030(B) | |
| Maximum density | 10 units per acre, on the net lot area ACC 18.09.030(A) | |
| Minimum development size | 217,800 sq ft ACC 18.09.030(C) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 10 ft ACC 18.09.030(G) | |
| Street side setback | ||
| Rear setback | ||
| Building separation | 10 ft ACC 18.09.030(J) | |
| Maximum height | 30 ft ACC 18.09.030(L) | |
| Minimum parking | 2 × 1.05 spaces per unit Table 18.52.020; 18.52.020 note 1; 18.09.030(P) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 × main dwelling units on the lot units ACC 18.32.010(B) | |
| Minimum lot size | 2,500 sq ft ACC 18.32.010(B); 18.09.030(D) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 10 ft ACC 18.09.030(G) | |
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft ACC 18.32.010(D) | |
| Attached to the main house | Not required ACC 18.32.010(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision ACC 17.09.060(A) | A12 | up to 9 ACC 17.09.010(A) | Minimum parent area 217,800 sq ft ACC 18.09.030(C) |
Minimum lot size 2,500 sq ft ACC 18.09.030(D) |
| Subdivision ACC 17.10.030; 17.10.050(A) | H | 10 or more ACC 17.01.020; 17.04.380; 17.09.010(A) | Minimum parent area 217,800 sq ft ACC 18.09.030(C) |
Minimum lot size 2,500 sq ft ACC 18.09.030(D) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The setback is measured from a manufactured home community street rather than a public or other private street
- None of these is true:
- The setback is measured from a manufactured home community street rather than a public or other private street
- The street along the side line of the home space is a manufactured home community street
- None of these is true:
- The street along the side line of the home space is a manufactured home community street
- The rear line of the home space abuts a manufactured home community street
- All of these are true:
- The rear line of the home space abuts a public or other private street
- The rear line of the home space abuts a manufactured home community street
- None of these is true:
- The rear line of the home space abuts a manufactured home community street
- The rear line of the home space abuts a public or other private street
- The ADU is detached from the main dwelling
- None of these is true:
- The ADU is detached from the main dwelling
- The lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The original tract was created by a short subdivision within the previous five years