Sign in

FTD · Ferry Terminal Overlay (Mixed Use Town Center)

Bainbridge Island, WA · BIMC 18.06.030(A)(5); 18.09; 18.12 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Family Dwelling
Home✓ ADU✓1
————
Commercial/Residential Mixed Use Developments
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Multifamily Dwellings—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Affordable Housing Development on Property Owned or Controlled by a Religious Organization—
HomeH2 ADU—
HomeH2 ADU—
HomeH2 ADU—
—
Foster Home————
Home✓ ADU✓1
Small Group Living Facility————
Home✓ ADU—
Group Care Facility————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum residentsNot set BIMC 18.36.030
6 persons BIMC 18.36.030
for Small Group Living Facility (group living)

3. Building standards

StandardValueExceptions
Maximum front setback5 ft BIMC Table 18.12.020-3
Side setback0 ft BIMC Table 18.12.020-3
Rear setback0 ft BIMC Table 18.12.020-3
Maximum height
  • Not read3 BIMC 18.12.030(C)
  • 35 ft4 BIMC Table 18.12.020-3
  • 45 ft5 BIMC Table 18.12.020-3 note [6]
Maximum lot coverage75% BIMC Table 18.12.020-3
Maximum floor area ratio
  • 0.46 BIMC Table 18.12.020-3
  • 1.17 BIMC Table 18.12.020-3; 18.12.030(E)(1)(a)
  • 0.58 BIMC Table 18.12.020-3
  • 0.79 BIMC Table 18.12.020-3 note [3]; 18.12.030(E)(2)
  • 1.210 BIMC Table 18.12.020-3; 18.12.030(E)(1)(a)
  • 1.411 BIMC Table 18.12.020-3 note [3]; 18.12.030(E)(2); 18.12.030(E)(1)(a)
for Commercial/Residential Mixed Use Developments (1, 2, 3, 4+ units)
1.2 BIMC Table 18.12.020-3 note [7]; 18.21.050(E)(1)
for Affordable Housing Development on Property Owned or Controlled by a Religious Organization (2, 3, 4+ units)2
Minimum parking
  • 1 space per unit12 BIMC Table 18.15.020-2
  • 2 spaces per unit13 BIMC Table 18.15.020-2
  • 1 space per unit14 BIMC Table 18.15.020-2 note [3]
  • 1.5 spaces per unit15 BIMC Table 18.15.020-2 note [3]
The amount of parking shall be determined as part of a transportation study or mobility assessment. BIMC 18.21.050(H)
for Affordable Housing Development on Property Owned or Controlled by a Religious Organization (2, 3, 4+ units)2
For special cases not covered by this table, parking requirements shall be established by the director. BIMC Table 18.15.020-2
for Foster Home (group living); Small Group Living Facility (group living); Group Care Facility (group living)
Maximum unit sizeNot set BIMC 18.12.020
1,400 sq ft BIMC 18.21.050(I)
for Affordable Housing Development on Property Owned or Controlled by a Religious Organization (2, 3, 4+ units)2
Minimum open space10% BIMC Table 18.09.020 note [1]; 18.09.020(D)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit BIMC 18.09.030(I)(5)(c)

Building

StandardValueExceptions
Side setback0 ft BIMC Table 18.12.020-3; 18.09.030(I)(5)(m)
Rear setback0 ft BIMC Table 18.12.020-3; 18.09.030(I)(5)(m)
Maximum height
  • Not read3 BIMC 18.12.030(C); 18.09.030(I)(5)(m)
  • 35 ft4 BIMC Table 18.12.020-3; 18.09.030(I)(5)(m)
  • 45 ft5 BIMC Table 18.12.020-3 note [6]; 18.09.030(I)(5)(m)
Minimum parking1 space per unit BIMC 18.09.030(I)(5)(e); BIMC Table 18.15.020-1
Maximum unit size1,000 sq ft BIMC 18.09.030(I)(5)(f)
Attached to the main houseNot required BIMC 18.09.030(I)(5)(a)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short Subdivision BIMC 2.16.070(A)-(C); 2.16.010 A up to 4 BIMC 17.28.020; 2.16.070(B) See FAR table BIMC Table 17.12.070-1
Minimum lot size
  • No limit16 BIMC Table 17.12.070-1
  • If the site is not served by a public sewer system, the minimum individual lot area shall be determined by the Kitsap Public Health District in accordance with Section 15 of the Kitsap County Board of Health Ordinance 2008A-01, amended June 7, 2011, Onsite Sewage System and General Sewage Sanitation Regulations, as amended.17 BIMC Table 17.12.070-1
Long Subdivision BIMC 2.16.125(B)-(C); 2.16.010 H 5 or more BIMC 17.28.020; 2.16.125(B) See FAR table BIMC Table 17.12.070-1
Minimum lot size
  • No limit16 BIMC Table 17.12.070-1
  • If the site is not served by a public sewer system, the minimum individual lot area shall be determined by the Kitsap Public Health District in accordance with Section 15 of the Kitsap County Board of Health Ordinance 2008A-01, amended June 7, 2011, Onsite Sewage System and General Sewage Sanitation Regulations, as amended.17 BIMC Table 17.12.070-1

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The ADU is part of a housing design demonstration project single-family subdivision approved under BIMC 2.16.020.S
    None of these is true:
    • Lot is within the shoreline jurisdiction of the shoreline master program (Chapter 16.12 BIMC)
  2. All of these are true:
    • Property is owned or controlled by a religious organization as defined in RCW 36.70A.545
    • Property is the approximately eight-acre property known as Bethany Lutheran Church, at the southwest intersection of NE High School Road and Sportsman Club Road NE
  3. Property is north of Winslow Way
  4. None of these is true:
    • Property is north of Winslow Way
    • Parking is located underground or under the occupiable space of the planned building
  5. All of these are true:
    • Parking is located underground or under the occupiable space of the planned building
    None of these is true:
    • Property is north of Winslow Way
  6. None of these is true:
    • Project uses the optional affordable housing FAR bonus, dedicating the bonus floor area to affordable housing
  7. Project uses the optional affordable housing FAR bonus, dedicating the bonus floor area to affordable housing
  8. None of these is true:
    • Project uses the optional affordable housing FAR bonus, dedicating the bonus floor area to affordable housing
    • Project relocates all existing legal surface ferry commuter parking on site to under-building or below-grade parking
  9. All of these are true:
    • Project relocates all existing legal surface ferry commuter parking on site to under-building or below-grade parking
    None of these is true:
    • Project uses the optional affordable housing FAR bonus, dedicating the bonus floor area to affordable housing
  10. All of these are true:
    • Project uses the optional affordable housing FAR bonus, dedicating the bonus floor area to affordable housing
    None of these is true:
    • Project relocates all existing legal surface ferry commuter parking on site to under-building or below-grade parking
  11. All of these are true:
    • Project uses the optional affordable housing FAR bonus, dedicating the bonus floor area to affordable housing
    • Project relocates all existing legal surface ferry commuter parking on site to under-building or below-grade parking
  12. Bedrooms in one unit is at most 1
  13. All of these are true:
    • Bedrooms in one unit is more than 1
    • Any of these is true:
      • None of these is true:
        • Dwelling is within a one-half-mile radius of the ferry terminal providing scheduled service to Seattle
        • Dwelling is between one-half mile and a one-mile radius of the ferry terminal providing scheduled service to Seattle
      • Project is senior housing or uses another parking reduction arrangement
  14. All of these are true:
    • Bedrooms in one unit is more than 1
    • Dwelling is within a one-half-mile radius of the ferry terminal providing scheduled service to Seattle
    None of these is true:
    • Project is senior housing or uses another parking reduction arrangement
  15. All of these are true:
    • Bedrooms in one unit is more than 1
    • Dwelling is between one-half mile and a one-mile radius of the ferry terminal providing scheduled service to Seattle
    None of these is true:
    • Project is senior housing or uses another parking reduction arrangement
  16. Site is served by a public sewer system
  17. None of these is true:
    • Site is served by a public sewer system