Sign in

D · Downtown (D)

Battle Ground, WA · BGMC 17.118 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Residences of all types, when located on upper floors of commercial buildings
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Live/work
HomeH2 ADU—
HomeH2 ADU—
HomeH2 ADU—
HomeH2 ADU—
—
Group living (seven or more residents)————
Home✓ ADU—
Co-living housing————
Home✓ ADU—
Transitional housing————
Home✓ ADU—
Emergency housing————
Home✓ ADU—
Emergency shelter————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size1,600 sq ft BGMC 17.118.030
Minimum frontage16 ft BGMC 17.118.030
Maximum residentsReasonable occupancy, spacing, and intensity of use requirements shall be reviewed under a site plan review process pursuant to Chapter 17.143 BGMC. BGMC 17.135.200(B)
Not set BGMC 17.118.030
for Group living (seven or more residents) (group living); Co-living housing (group living)

3. Building standards

StandardValueExceptions
Maximum front setback0 ft BGMC 17.118.030
Side setback
  • 0 ft3 BGMC 17.118.030
  • Pursuant to the screening and buffering standards contained in Chapter 17.131 BGMC, Table 17.131-1, plus an additional 1/2 foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.4 BGMC 17.118.030
Rear setback
  • 0 ft3 BGMC 17.118.030
  • Pursuant to the screening and buffering standards contained in Chapter 17.131 BGMC, Table 17.131-1, plus an additional 1/2 foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.4 BGMC 17.118.030
Building separation0 ft BGMC 17.118.030
Maximum height60 ft BGMC 17.118.030
Maximum lot coverageMaximum determined by compliance with screening and buffering standards contained in Chapter 17.131 BGMC, Table 17.131-1, parking and loading standards of Chapter 17.133 BGMC, the stormwater control ordinance (Chapter 18.250 BGMC) and all other applicable standards. BGMC 17.118.030
Minimum parking0 spaces per unit BGMC 17.133.040(E)
Minimum open space0% BGMC 17.118.030

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat (two lots) BGMC 16.115.040(A)(1); 16.105.030(C) A 2 to 2 BGMC 16.110.010; 16.115.040(A)(1) —
Minimum lot size
1,600 sq ft BGMC 17.118.030
Minimum frontage
16 ft BGMC 17.118.030
Short plat (three to nine lots) / short subdivision BGMC 16.115.040(A)(2); 16.105.030(C) A 3 to 9 BGMC 16.110.010; 16.115.040(A)(2) —
Minimum lot size
1,600 sq ft BGMC 17.118.030
Minimum frontage
16 ft BGMC 17.118.030
Subdivision (ten or more lots) BGMC 16.115.040(A)(3); 16.105.030(B) H 10 or more BGMC 16.110.010; 16.115.040(A)(3) —
Minimum lot size
1,600 sq ft BGMC 17.118.030
Minimum frontage
16 ft BGMC 17.118.030
Binding site plan BGMC 17.143.035(A) A
Maximum lots
Not set BGMC 17.143.035
—
Minimum lot size
1,600 sq ft BGMC 17.118.030
Minimum frontage
16 ft BGMC 17.118.030

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The residences are on upper floors of a commercial building
    • The ground floor is 100% commercial or office use along any street frontage for a depth of at least 20 feet
  2. The ground floor of the live/work unit is used for nonresidential purposes
  3. None of these is true:
    • The yard abuts a residential district (the setback applies on that side only)
  4. The yard abuts a residential district (the setback applies on that side only)