Sign in

GW · Gateway

Blaine, WA · BMC 17.12 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
One dwelling unit for each permitted use
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Health care and social assistance (NAICS No. 62)————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsOne dwelling unit for each permitted use when it can be demonstrated that the unit is used in conjunction with, and accessory to, the permitted use; BMC 17.12.050(E)
Minimum lot sizeThe minimum lot size shall be adequate to meet the requirements and standards that apply to this district. BMC 17.12.070(A)
Minimum lot widthThe minimum lot width shall be of an adequate size to meet the requirements and standards that apply to this district. BMC 17.12.070(C)
Minimum lot depthThe minimum lot depth shall be adequate to meet the requirements and standards that apply to this district. BMC 17.12.070(D)
Minimum frontage30 ft BMC 17.12.070(B)

3. Building standards

StandardValueExceptions
Front setback20 + (the largest of 0, building height − 35) ft BMC 17.12.070(F)(1); 17.12.070(F)(3)
Side setback10 + (the largest of 0, building height − 35) ft BMC 17.12.070(F)(2)-(3)
Street side setback20 + (the largest of 0, building height − 35) ft BMC 17.12.070(F)(1); 17.12.070(F)(3)
Rear setback10 + (the largest of 0, building height − 35) ft BMC 17.12.070(F)(2)-(3)
Maximum height50 ft BMC 17.12.070(G)
Maximum impervious surface
  • 100%2 BMC 17.12.070(E)(2)
  • 80%3 BMC 17.12.070(E)(1)
Minimum parkingNot read BMC 17.12.070(H); 17.124.080

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 17.58.040(A); Table 17.06.A A up to 9 BMC 17.58.020 —
Minimum lot size
The minimum lot size shall be adequate to meet the requirements and standards that apply to this district. BMC 17.12.070(A)
Minimum lot width
The minimum lot width shall be of an adequate size to meet the requirements and standards that apply to this district. BMC 17.12.070(C)
Preliminary plat BMC 17.60.120(A); 17.06.040(A)(1)(b); Table 17.06.A A 10 to 99 BMC 17.60.020; BMC Table 17.06.A —
Minimum lot size
The minimum lot size shall be adequate to meet the requirements and standards that apply to this district. BMC 17.12.070(A)
Minimum lot width
The minimum lot width shall be of an adequate size to meet the requirements and standards that apply to this district. BMC 17.12.070(C)
Preliminary plat BMC 17.60.120(B); 17.60.130; Table 17.06.A H 100 or more BMC Table 17.06.A —
Minimum lot size
The minimum lot size shall be adequate to meet the requirements and standards that apply to this district. BMC 17.12.070(A)
Minimum lot width
The minimum lot width shall be of an adequate size to meet the requirements and standards that apply to this district. BMC 17.12.070(C)
Binding site plan BMC 17.64.010; Table 17.06.A A
Minimum lots
Not set BMC 17.64
—
Minimum lot size
The minimum lot size shall be adequate to meet the requirements and standards that apply to this district. BMC 17.12.070(A)
Minimum lot width
The minimum lot width shall be of an adequate size to meet the requirements and standards that apply to this district. BMC 17.12.070(C)
Planned unit development (PUD) BMC 17.68.020(D); 17.02.050(B)(3)(a); Table 17.06.A H4 — Residential uses in PUDs in PC, HCx, GW and MPR districts shall be as permitted by the review authority. BMC 17.68.030(B)
Minimum parent area
217,800 sq ft BMC 17.68.020(A)
Minimum lot size
To permit greater flexibility and consequently more creative and imaginative design for the development of residential and business uses than is generally possible under conventional zoning regulations including alteration of bulk and scale requirements as may be included in the underlying zoning district; BMC 17.68.010(A); 17.68.090(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Each dwelling unit is used in conjunction with, and accessory to, its own permitted use on the site (one unit per permitted use)
  2. The site is served by a regional storm water system
  3. None of these is true:
    • The site is served by a regional storm water system
  4. Lot area is at least 217,800 sf