1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Family Residence | — | — | — | — | |
| Manufactured home (designated) | — | — | — | — | |
| Attached Single-Family Dwelling Units | — | — | |||
| Manufactured home park | — | — | — | HomeA ADU— | — |
| Retirement homes | — | — | — | — | HomeH ADU— |
| Boardinghouse or roominghouse | — | — | — | — | HomeH ADU— |
| Nursing or convalescent home | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set BMC 17.116.050
for Manufactured home park (4+ units) | |
| Minimum lot width | Not set BMC 17.116.050
for Manufactured home park (4+ units) | |
| Maximum density | 1.5 × 4 units per acre BMC 17.116.050(A)(1); 17.42.050
for Manufactured home park (4+ units) | |
| Minimum development size | Not set BMC 17.42 | 130,680 sq ft BMC 17.116.050(B)(1)
for Manufactured home park (4+ units) |
| Maximum residents | Not set BMC 17.42 | 5 persons BMC 17.142.080
for Boardinghouse or roominghouse (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft BMC 17.116.060(B)(3)
for Manufactured home park (4+ units) | |
| Side setback | 0 ft BMC 17.116.060(B)(4)
for Manufactured home park (4+ units) | |
| Street side setback | Not set BMC 17.116.060
for Manufactured home park (4+ units) | |
| Rear setback | 0 ft BMC 17.116.060(B)(4)
for Manufactured home park (4+ units) | |
| Building separation | Not set BMC 17.42 | 10 ft BMC 17.116.060(B)(1)
for Manufactured home park (4+ units) |
| Maximum height | 30 ft BMC 17.116.060(C)(1); 17.42.060(B)
for Manufactured home park (4+ units) | |
| Maximum stories | Not set BMC 17.116.060
for Manufactured home park (4+ units) | |
| Maximum lot coverage | Not set BMC 17.42 | 50% BMC 17.116.060(A)
for Manufactured home park (4+ units) |
| Minimum parking | Not read BMC 17.42.070; 17.124.080 | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces BMC 17.116.050(E)(1)-(2)
for Manufactured home park (4+ units) |
| Maximum lot size | Not set BMC 17.42 | 653,400 sq ft BMC 17.116.050(B)(2)
for Manufactured home park (4+ units) |
| Minimum open space | 20% BMC 17.116.050(G)(1)
for Manufactured home park (4+ units) | |
| Maximum units per building | Not set BMC 17.42 | 4 units BMC 17.42.020(B)
for Attached Single-Family Dwelling Units (2, 3, 4+ units)14 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit BMC 17.102.020 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Detached accessory dwelling units shall not be forward of the primary unit in relation to any public street. BMC 17.102.050(A) | |
| Side setback | 4 ft BMC 17.102.050(A); 17.104.010 | Conversion of an existing accessory structure, noncompliant with the accessory structure setbacks, on an otherwise compliant lot may be conditionally permitted without a variance. Under no circumstance may the accessory structure encroach onto adjacent private or public property BMC 17.102.030(B)(1)
|
| Rear setback | 8 ft BMC 17.102.050(A); 17.104.010 | Conversion of an existing accessory structure, noncompliant with the accessory structure setbacks, on an otherwise compliant lot may be conditionally permitted without a variance. Under no circumstance may the accessory structure encroach onto adjacent private or public property BMC 17.102.030(B)(1)
|
| Maximum height | 28 ft BMC 17.102.050(I) | |
| Maximum stories | ||
| Minimum parking | Not read BMC 17.102.050(E); 17.124.080 | |
| Maximum unit size | 1,000 sq ft BMC 17.102.030(B)(2) | Not read BMC 17.102.030(A)(1)
the smallest of 0.5 × floor area of the main house, 600 sq ft BMC 17.102.030(A)(2)
the smallest of 0.5 × floor area of the main house, 800 sq ft BMC 17.102.030(A)(2)
the smallest of 0.5 × floor area of the main house, 1,000 sq ft BMC 17.102.030(A)(2)
|
| Attached to the main house | Not required BMC 17.102.030(A)(1)-(2); 17.142.027 | |
| Owner lives on site | Required BMC 17.102.050(C); 17.102.070(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 17.58.040(A); Table 17.06.A | A24 | up to 9 BMC 17.58.020 | — | Minimum lot width 75 ft BMC 17.42.060(D) |
| Preliminary plat BMC 17.60.120(A); 17.06.040(A)(1)(b); Table 17.06.A | A24 | 10 to 99 BMC 17.60.020; BMC Table 17.06.A | Minimum density 4 units per acre BMC 17.42.050(A) |
Minimum lot width 75 ft BMC 17.42.060(D) |
| Preliminary plat BMC 17.60.120(B); 17.60.130; Table 17.06.A | H24 | 100 or more BMC Table 17.06.A | Minimum density 4 units per acre BMC 17.42.050(A) |
Minimum lot width 75 ft BMC 17.42.060(D) |
| Planned unit development (PUD) BMC 17.68.020(D); 17.02.050(B)(3)(a); Table 17.06.A | H25 | — | Minimum parent area 130,680 sq ft BMC 17.68.020(A) |
Minimum lot size 4,000 sq ft BMC 17.68.120(C) Minimum lot width Lots within a residential PUD may vary from the depth, width and size requirements established in the code for the underlying zoning district, as determined to be suitable for the proposed PUD subject to the standards of this chapter. BMC 17.68.120(F) |
| Manufactured home subdivision BMC 17.42.020(G); 17.114.020; 17.114.030; Table 17.06.AOnly for: Manufactured home (designated) | A | 10 or more BMC 17.114.040(A) | — | Minimum lot width 75 ft BMC 17.42.060(D) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The lot is served by public water and sewer
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The lot is served by public water and sewer
- Lot area is at least 6,000 sf
- Lot area is at most 8,000 sf
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The lot is served by public water and sewer
- Lot area is more than 8,000 sf
- Lot area is at most 11,000 sf
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The lot is served by public water and sewer
- Lot area is more than 11,000 sf
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- The lot is served by public water and sewer
- All of these are true:
- The lot is served by public water and sewer
- The ADU converts an existing accessory structure that does not meet the accessory structure setbacks, on an otherwise compliant lot
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- All of these are true:
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The lot is served by public water and sewer
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The lot is served by public water and sewer
- Lot area is at least 6,000 sf
- Lot area is at most 8,000 sf
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The lot is served by public water and sewer
- Lot area is more than 8,000 sf
- Lot area is at most 11,000 sf
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The lot is served by public water and sewer
- Lot area is more than 11,000 sf
- The detached ADU substantially complies with the city ADU Templates 1 through 4
- All of these are true:
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The lot is served by public water and sewer
- All of these are true:
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The lot is served by public water and sewer
- The ADU converts an existing accessory structure that does not meet the accessory structure setbacks, on an otherwise compliant lot
- Public sewer, water, storm water collection (quality) and retention (quantity) facilities serve the site
- None of these is true:
- Public sewer, water, storm water collection (quality) and retention (quantity) facilities serve the site
- The property is developed as a planned unit development
- None of these is true:
- The property is developed as a planned unit development
- All of these are true:
- The lot is a corner lot
- The property is developed as a planned unit development
- None of these is true:
- The property is developed as a planned unit development
- The lot is a corner lot
- Floor area of the main house is less than 2,000
- All of these are true:
- Floor area of the main house is at least 2,000
- Floor area of the main house is less than 3,000
- All of these are true:
- Floor area of the main house is at least 3,000
- Floor area of the main house is less than 5,000
- Floor area of the main house is at least 5,000
- Lot area is at most 217,800 sf
- Lot area is at least 130,680 sf
- None of these is true:
- The PUD uses the superior design density bonuses (up to 20% above base density)
- The PUD uses the superior design density bonuses (up to 20% above base density)