Sign in

SF-2 · Single-family two

Blaine, WA · BMC 17.31 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Family Residence
Home✓ ADUA1 A2 A3 A4 A H5
————
Manufactured home (designated)
Home✓6 ADUA7 A8 A9 A10 A6 H6 H11
————
Attached Single-Family Dwelling Units
Home✓ ADU—
————
Adult family care facility————
HomeA ADU—
Nursing or convalescent home————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size6,000 sq ft BMC 17.31.040
3,750 sq ft BMC 17.31.040
for Attached Single-Family Dwelling Units (1 unit)
Minimum lot width50 ft BMC 17.31.040
37.5 ft BMC 17.31.040
for Attached Single-Family Dwelling Units (1 unit)
Maximum residents
  • 6 persons12 BMC 17.142.045
  • 4 persons13 BMC 17.142.045
Not set BMC 17.31.040
for Nursing or convalescent home (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft BMC 17.31.040
Side setback8 ft BMC 17.31.040
10 ft BMC 17.31.040
for Attached Single-Family Dwelling Units (1 unit)
Street side setback15 ft BMC 17.31.040
Rear setback
  • 8 ft14 BMC 17.31.040
  • 20 ft15 BMC 17.31.040
  • 10 ft14 BMC 17.31.040
  • 20 ft15 BMC 17.31.040
for Attached Single-Family Dwelling Units (1 unit)
Maximum height35 ft BMC 17.31.040
Maximum stories2 stories BMC 17.31.040
Minimum parking2 spaces per unit BMC 17.31.040; 17.121.060(B)(3)
2 + 2 spaces BMC 17.100.030(E)
for Adult family care facility (group living)
Not read BMC 17.124.080
for Nursing or convalescent home (group living)
Minimum open space40% BMC 17.31.040

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit BMC 17.102.020

Building

StandardValueExceptions
Front setbackDetached accessory dwelling units shall not be forward of the primary unit in relation to any public street. BMC 17.102.050(A)
20 ft BMC 17.31.040
for Single-Family Residence (1 unit); Manufactured home (designated) (1 unit)6
Side setback4 ft BMC 17.102.050(A); 17.104.010
8 ft BMC 17.31.040
for Single-Family Residence (1 unit); Manufactured home (designated) (1 unit)6
Conversion of an existing accessory structure, noncompliant with the accessory structure setbacks, on an otherwise compliant lot may be conditionally permitted without a variance. Under no circumstance may the accessory structure encroach onto adjacent private or public property BMC 17.102.030(B)(1)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)11
Rear setback8 ft BMC 17.102.050(A); 17.104.010
  • 8 ft14 BMC 17.31.040
  • 20 ft15 BMC 17.31.040
for Single-Family Residence (1 unit); Manufactured home (designated) (1 unit)6
Conversion of an existing accessory structure, noncompliant with the accessory structure setbacks, on an otherwise compliant lot may be conditionally permitted without a variance. Under no circumstance may the accessory structure encroach onto adjacent private or public property BMC 17.102.030(B)(1)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)11
Maximum height28 ft BMC 17.102.050(I)
35 ft BMC 17.31.040
for Single-Family Residence (1 unit); Manufactured home (designated) (1 unit)6
Maximum stories2 stories BMC 17.31.040
Minimum parkingNot read BMC 17.102.050(E); 17.124.080
Maximum unit size1,000 sq ft BMC 17.102.030(B)(2)
Not read BMC 17.102.030(A)(1)
for Single-Family Residence (1 unit)1; Manufactured home (designated) (1 unit)7
the smallest of 0.5 × floor area of the main house, 600 sq ft BMC 17.102.030(A)(2)
for Single-Family Residence (1 unit)2; Manufactured home (designated) (1 unit)8
the smallest of 0.5 × floor area of the main house, 800 sq ft BMC 17.102.030(A)(2)
for Single-Family Residence (1 unit)3; Manufactured home (designated) (1 unit)9
the smallest of 0.5 × floor area of the main house, 1,000 sq ft BMC 17.102.030(A)(2)
for Single-Family Residence (1 unit)4; Manufactured home (designated) (1 unit)10
  • 0.5 × floor area of the main house sq ft16 BMC 17.102.030(A)(3)
  • the smallest of 0.4 × floor area of the main house, 1,000 sq ft17 BMC 17.102.030(A)(3)
  • the smallest of 0.3 × floor area of the main house, 1,200 sq ft18 BMC 17.102.030(A)(3)
  • the smallest of 0.2 × floor area of the main house, 1,500 sq ft19 BMC 17.102.030(A)(3)
for Single-Family Residence (1 unit); Manufactured home (designated) (1 unit)6
Attached to the main houseNot required BMC 17.102.030(A)(1)-(2); 17.142.027
Required BMC 17.102.030(A)(3)
for Single-Family Residence (1 unit); Manufactured home (designated) (1 unit)6
Owner lives on siteRequired BMC 17.102.050(C); 17.102.070(C)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 17.58.040(A); Table 17.06.A A up to 9 BMC 17.58.020 —
Minimum lot size
6,000 sq ft BMC 17.31.040
Minimum lot width
50 ft BMC 17.31.040
Preliminary plat BMC 17.60.120(A); 17.06.040(A)(1)(b); Table 17.06.A A 10 to 99 BMC 17.60.020; BMC Table 17.06.A —
Minimum lot size
6,000 sq ft BMC 17.31.040
Minimum lot width
50 ft BMC 17.31.040
Preliminary plat BMC 17.60.120(B); 17.60.130; Table 17.06.A H 100 or more BMC Table 17.06.A —
Minimum lot size
6,000 sq ft BMC 17.31.040
Minimum lot width
50 ft BMC 17.31.040
Planned unit development (PUD) BMC 17.68.020(D); 17.02.050(B)(3)(a); Table 17.06.A H20 —
  • 9 units per acre21 BMC 17.68.120(B); 17.68.125
  • 9 × 1.2 units per acre22 BMC 17.68.125; 17.68.130
Minimum parent area
130,680 sq ft BMC 17.68.020(A)
Minimum lot size
4,000 sq ft BMC 17.68.120(C)
Minimum lot width
Lots within a residential PUD may vary from the depth, width and size requirements established in the code for the underlying zoning district, as determined to be suitable for the proposed PUD subject to the standards of this chapter. BMC 17.68.120(F)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The detached ADU substantially complies with the city ADU Templates 1 through 4
  2. All of these are true:
    • Lot area is at least 6,000 sf
    • Lot area is at most 8,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  3. All of these are true:
    • Lot area is more than 8,000 sf
    • Lot area is at most 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  4. All of these are true:
    • Lot area is more than 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  5. The ADU converts an existing accessory structure that does not meet the accessory structure setbacks, on an otherwise compliant lot
  6. The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
  7. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  8. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • Lot area is at least 6,000 sf
    • Lot area is at most 8,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  9. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • Lot area is more than 8,000 sf
    • Lot area is at most 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  10. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • Lot area is more than 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  11. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The ADU converts an existing accessory structure that does not meet the accessory structure setbacks, on an otherwise compliant lot
  12. The state licensing department determines the home and provider can serve up to six adults
  13. None of these is true:
    • The state licensing department determines the home and provider can serve up to six adults
  14. The lot is a corner lot
  15. None of these is true:
    • The lot is a corner lot
  16. Floor area of the main house is less than 2,000
  17. All of these are true:
    • Floor area of the main house is at least 2,000
    • Floor area of the main house is less than 3,000
  18. All of these are true:
    • Floor area of the main house is at least 3,000
    • Floor area of the main house is less than 5,000
  19. Floor area of the main house is at least 5,000
  20. Lot area is at least 130,680 sf
  21. None of these is true:
    • The PUD uses the superior design density bonuses (up to 20% above base density)
  22. The PUD uses the superior design density bonuses (up to 20% above base density)