Sign in

Neighborhood_Business · Neighborhood business (NB)

Bremerton, WA · BMC 20.82 · Official code

By right: 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Residential as a secondary use
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Senior housing complex———
Home✓2 ADU—
—
Manufactured home park———
Home✓ ADU—
—
Group residential facilities - Class I————
Home✓ ADU—
Co-living housing————
Home✓ ADU—
Transitional housing————
HomeA ADU—
Permanent supportive housing————
HomeA ADU—
Indoor emergency shelter————
HomeA ADU—
Indoor emergency housing————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set BMC 20.82.060
87,120 sq ft BMC 20.46.190(a)(1)
for Senior housing complex (4+ units)2
217,800 sq ft BMC 20.46.200(a)(2)
for Manufactured home park (4+ units)
Minimum frontage20 ft BMC 20.42.040
Minimum density15 units per acre BMC 20.82.060(h)
Not set BMC 20.82.060(h)
for Group residential facilities - Class I (group living); Co-living housing (group living); Transitional housing (group living); Permanent supportive housing (group living); Indoor emergency shelter (group living); Indoor emergency housing (group living)
Maximum densityNo limit BMC 20.82.060(h)
Not set BMC 20.82.060(h)
for Group residential facilities - Class I (group living); Co-living housing (group living); Transitional housing (group living); Permanent supportive housing (group living); Indoor emergency shelter (group living); Indoor emergency housing (group living)
Maximum sleeping unitsNot set BMC 20.42.040
No limit BMC 20.82.060(h); 20.46.230(c)
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Maximum front setback10 ft BMC 20.82.060(a)
Side setback
  • 0 ft3 BMC 20.82.060(b)
  • 10 ft4 BMC 20.82.060(b); 20.50.050(b)(1)(i)
0 ft BMC 20.82.060(b)
for Residential as a secondary use (1, 2 units)1
Rear setback
  • 0 ft3 BMC 20.82.060(c)
  • 10 ft4 BMC 20.82.060(c); 20.50.050(b)(1)(i)
0 ft BMC 20.82.060(c)
for Residential as a secondary use (1, 2 units)1
Building separationNot set BMC 20.82.060
10 ft BMC 20.46.200(a)(7); 20.46.200(a)(7)(iii)
for Manufactured home park (4+ units)
Maximum height35 ft BMC 20.82.060(g)
Maximum lot coverage
  • 60%5 BMC 20.82.060(e)
  • 85%6 BMC 20.82.060(e)
Maximum impervious surface
  • 75%5 BMC 20.82.060(f); 20.42.040
  • 95%6 BMC 20.82.060(f)
Minimum parking0 spaces per unit BMC 20.82.080; 20.48.080(l)
Minimum open spaceNot set BMC 20.82.060
10% BMC 20.46.200(a)(10)
for Manufactured home park (4+ units)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 20.12.090(a)(1)(i) A up to 9 BMC 20.12.080(a); 20.12.040 —
Minimum lot size
Not set BMC 20.82.060
Minimum lot width
Not set BMC 20.82.060
Minimum frontage
20 ft BMC 20.42.040
Formal subdivision BMC 20.12.090(a)(2)(i) H 10 or more BMC 20.12.080(b); 20.12.040 —
Minimum lot size
Not set BMC 20.82.060
Minimum lot width
Not set BMC 20.82.060
Minimum frontage
20 ft BMC 20.42.040
Unit lot subdivision BMC 20.12.090(a)(4)(i) A up to 9 BMC 20.12.080(d) —
Minimum lot size
Not set BMC 20.12.090(a)(4)(i); 20.12.080(d)
Minimum lot width
Not set BMC 20.12.090(a)(4)(i); 20.12.080(d)
Binding site plan BMC 20.12.090(a)(3)(i) A7
Maximum lots
Not set BMC 20.12.080(c); 20.12.040
—
Minimum lot size
Not set BMC 20.82.060
Minimum lot width
Not set BMC 20.82.060
Minimum frontage
20 ft BMC 20.42.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residential use is secondary and subordinate to the principal nonresidential uses and is not in street-level frontage reserved for retail, office and other business uses
  2. The complex provides access to alternative transportation such as public transit or on-site shuttle services to reach daily goods and services
  3. None of these is true:
    • This lot line adjoins a residential zone
  4. This lot line adjoins a residential zone
  5. None of these is true:
    • The project uses the NB coverage bonus menu (mixed use, two- or three-story building, pedestrian plaza, through-block corridor, structured parking)
  6. The project uses the NB coverage bonus menu (mixed use, two- or three-story building, pedestrian plaza, through-block corridor, structured parking)
  7. The land division is for a commercial and/or industrial development