BN · Neighborhood business zone
Brier, WA · BMC 17.30 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Adult family home | — | — | — | — | |
| Group home | — | — | — | — | |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft BMC 17.30.060(A)(1) | |
| Side setback | ||
| Rear setback |
|
|
| Maximum height | 30 ft BMC 17.30.060(C) | |
| Maximum lot coverage | 75% BMC 17.30.060(E) | |
| Maximum impervious surface | 75% BMC 17.30.060(E); 17.04.040 | |
| Minimum parking | All non-single-family residential uses shall provide parking based on anticipated parking demand. For sites with over two thousand square feet of parking area or five thousand square feet of total impervious surface, the study shall be completed by a professional engineer or equally qualified individual with expertise in parking analyses. BMC 17.30.060(D); 17.48.045(B)(1) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 16.32.050(M); 16.04.020(A) | A | up to 4 BMC 16.04.030 | — | Minimum lot size Not set BMC 16.16.130; 17.30.060 Minimum lot width Not set BMC 16.16.130; 17.30.060 Minimum lot depth 100 ft BMC 16.16.040(I) Minimum frontage 45 ft BMC 16.16.130(A) Maximum units per lot Not set BMC 17.30 |
| Subdivision BMC 16.24.010; 16.24.030 | H | 5 or more BMC 16.04.030 | — | Minimum lot size Not set BMC 16.16.130; 17.30.060 Minimum lot width Not set BMC 16.16.130; 17.30.060 Minimum lot depth 100 ft BMC 16.16.040(I) Minimum frontage 45 ft BMC 16.16.130(A) Maximum units per lot Not set BMC 17.30 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The operator is certified by the state of Washington (adult family homes, Chapter 388-76 WAC; group homes, Chapter 110-145 WAC)
- The home is located in the dwelling unit occupied by the licensed operator
- The dwelling unit is not located on the ground floor along the street front, which is reserved for commercial or office uses
- The dwelling unit is used as a residence for the caretaker or resident owner of a permitted use, attached or detached to that use
- All of these are true:
- The dwelling unit is not located on the ground floor along the street front, which is reserved for commercial or office uses
- The dwelling unit is used as a residence for the caretaker or resident owner of a permitted use, attached or detached to that use
- The BN lot is adjacent to residential uses or residential zoned properties
- None of these is true:
- The BN lot is adjacent to residential uses or residential zoned properties