Sign in

HDR · HDR-High, high density residential (high) zone

Buckley, WA · BMC 19.20.060 · Official code

By right: 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Multiplex———
Home✓ ADU—
—
Courtyard apartment———
Home✓ ADU—
—
Low-rise apartment complex———
Home✓ ADU—
—
Cottage housing development———
HomeH ADU—
—
Adult family home————
Home✓ ADU—
Group home————
Home✓ ADU—
Assisted living facility————
Home✓ ADU—
Co-living housing————
Home✓ ADU—
Nursing home————
Home✓ ADU—
Permanent supportive housing (PSH)————
Home✓ ADU—
Emergency housing (EH)————
Home✓ ADU—
Emergency shelter (ES)————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units12 units BMC 19.12.164
20 units BMC 19.12.156
for Courtyard apartment (4+ units)
Not set BMC 19.20.060(4)
for Low-rise apartment complex (4+ units)
Minimum unitsNot set BMC 19.20.060(4)
5 units BMC 19.12.164
for Multiplex (4+ units)
4 units BMC 19.24.020(1)(b)
for Cottage housing development (4+ units)
Maximum densityNot set BMC 19.20.060(4)
1 unit per 2,500 sq ft BMC 19.24.020(3)(b)
for Cottage housing development (4+ units)
Minimum development sizeNot set BMC 19.20.060(4)
43,560 sq ft BMC 19.24.020(1)(a)
for Cottage housing development (4+ units)
Maximum sleeping unitsNot set BMC 19.20.060(4)
The maximum number of sleeping units can be no greater than four times the unit density of the underlying zone. BMC 19.12.142
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Front setback8 ft BMC 19.20.060(4)
7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units)
Side setback5 ft BMC 19.20.060(4)
7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units)
Street side setback8 ft BMC 19.20.060(4) note 1
7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units)
Rear setback
  • 5 ft1 BMC 19.20.060(4)
  • 10 ft2 BMC 19.20.060(4)
7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units)
Building separationNot set BMC 19.20.060(4)
10 ft BMC 19.24.020(11)(b)
for Cottage housing development (4+ units)
Maximum height35 ft BMC 19.20.060(4)
18 ft BMC 19.24.020(10)
for Cottage housing development (4+ units)
Maximum storiesNot set BMC 19.20.060(4)
3 stories BMC 19.12.159
for Low-rise apartment complex (4+ units)
Minimum storiesNot set BMC 19.20.060(4)
2 stories BMC 19.12.159
for Low-rise apartment complex (4+ units)
Maximum lot coverage65% BMC 19.20.060(4)
60% BMC 19.24.020(12)
for Cottage housing development (4+ units)
Maximum impervious surface85% BMC 19.20.060(4)
Not set BMC 19.24.020
for Cottage housing development (4+ units)
Minimum parkingNot set BMC 19.28.040(1)
1.5 spaces per unit BMC 19.28.040(1)
for Multiplex (4+ units)
  • 1 space per unit3 BMC 19.28.040(1)
  • 1.5 spaces per unit4 BMC 19.28.040(1)
for Courtyard apartment (4+ units); Low-rise apartment complex (4+ units)
2 spaces per unit BMC 19.24.020(9)(a)
for Cottage housing development (4+ units)
(beds in the project ÷ 2) + employees on the largest shift spaces BMC 19.28.040(1)
for Adult family home (group living); Group home (group living); Assisted living facility (group living)
Maximum unit sizeNot set BMC 19.20.060(4)
1,200 sq ft BMC 19.24.020(4)(a)
for Cottage housing development (4+ units)
Minimum open space10% BMC 19.20.060(4)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 18.26.050(1) A 2 to 6 BMC 18.26.010(1); BMC 18.12.250; 18.26.010(1) —
Minimum lot size
Not set BMC 19.20.060(4)
Subdivision BMC 18.22.010(4) H 7 or more BMC 18.12.320 —
Minimum lot size
Not set BMC 19.20.060(4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The rear lot line abuts an alley (off-alley lot)
  2. None of these is true:
    • The rear lot line abuts an alley (off-alley lot)
  3. Bedrooms in one unit is less than 2
  4. Bedrooms in one unit is at least 2