R-8000 · R-8,000 residential zone
Buckley, WA · BMC 19.20.030 · Official code
By right: 1 unit, 2 units, 3 units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | Home✓ ADU✓ | — | — | — | — |
| Two-family dwelling | — | Home✓ ADU— | — | — | — |
| Townhome dwelling | — | Home✓ ADU— | Home✓ ADU— | — | — |
| Three-family dwelling | — | — | Home✓ ADU— | — | — |
| Cottage housing development | — | — | — | HomeH ADU— | — |
| Adult family home | — | — | — | — | Home✓ ADU✓ |
| Group home | — | — | — | — | Home✓ ADU✓ |
| Permanent supportive housing (PSH) | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 3 units, ADUs included BMC 19.20.030(2)(a) | 12 units BMC 19.24.020(1)(b)
for Cottage housing development (4+ units) |
| Minimum units | 4 units BMC 19.24.020(1)(b) | |
| Minimum lot size | 8,000 sq ft BMC 19.20.030(2)(a) | 4,000 × main dwelling units on the lot sq ft BMC 19.20.030(2)(a)
for Townhome dwelling (2, 3 units) 12,000 sq ft BMC 19.20.030(2)(a)
for Three-family dwelling (3 units) Not set BMC 19.24.020
for Cottage housing development (4+ units) |
| Minimum lot depth | 100 ft BMC 19.20.030(2)(a) | Not set BMC 19.24.020
for Cottage housing development (4+ units) |
| Minimum frontage | for Two-family dwelling (2 units); Townhome dwelling (2, 3 units); Three-family dwelling (3 units) Not set BMC 19.24.020
for Cottage housing development (4+ units) | |
| Maximum density | Not set BMC 19.20.030(2)(a) | The number calculated in subsection (3)(a)(i) of this section shall be multiplied by one and six-tenths. Fractional numbers of one-half or greater shall be rounded up. BMC 19.24.020(3)(a)
for Cottage housing development (4+ units) |
| Minimum development size | Not set BMC 19.20.030(2)(a) | 43,560 sq ft BMC 19.24.020(1)(a)
for Cottage housing development (4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft BMC 19.20.030(2)(a) | 7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units) |
| Side setback | 8 ft BMC 19.20.030(2)(a) | 7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units) |
| Street side setback | 15 ft BMC 19.20.030(2)(a) note 4 | 7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units) |
| Rear setback | 20 ft BMC 19.20.030(2)(a) | 7 ft BMC 19.24.020(11)(c)
for Cottage housing development (4+ units) |
| Building separation | 10 ft BMC 19.20.030(2)(a); 19.20.030(3) | |
| Maximum height | 30 ft BMC 19.20.030(2)(a); 19.20.010(1)(a) | 18 ft BMC 19.24.020(10)
for Cottage housing development (4+ units) |
| Maximum lot coverage | 40% BMC 19.20.030(2)(a) | 60% BMC 19.24.020(12)
for Cottage housing development (4+ units) |
| Maximum impervious surface | 55% BMC 19.20.030(2)(a) | Not set BMC 19.24.020
for Cottage housing development (4+ units) |
| Minimum parking | 2 spaces per unit BMC 19.28.040(1) | 1.5 spaces per unit BMC 19.28.040(1)
for Three-family dwelling (3 units) (beds in the project ÷ 2) + employees on the largest shift spaces BMC 19.28.040(1)
for Adult family home (group living); Group home (group living) Not set BMC 19.28.040(1)
for Permanent supportive housing (PSH) (group living) |
| Maximum unit size | Not set BMC 19.20.030(2)(a) | 1,200 sq ft BMC 19.24.020(4)(a)
for Cottage housing development (4+ units) |
| Maximum building footprint | 3,200 sq ft BMC 19.20.030(2)(a) | Not set BMC 19.24.020
for Cottage housing development (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units BMC 19.22.130(2); BMC 19.20.030(2)(a) note 1 | |
| Minimum lot size | 8,000 sq ft BMC 19.22.130(4); BMC 19.20.030(2)(a) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft BMC 19.20.030(2)(a) | |
| Side setback | 8 ft BMC 19.20.030(2)(a) | |
| Rear setback | ||
| Maximum height | 30 ft BMC 19.20.030(2)(a); 19.20.010(1)(a) | |
| Minimum parking | 1 space per unit BMC 19.22.130(9)(b); 19.28.040(1) | |
| Maximum unit size | 1,250 sq ft BMC 19.22.130(7) | |
| Attached to the main house | Not required BMC 19.22.130(3) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 18.26.050(1) | A | 2 to 6 BMC 18.26.010(1); BMC 18.12.250; 18.26.010(1) | — | Minimum lot size 8,000 sq ft BMC 19.20.030(2)(a) Minimum lot depth 100 ft BMC 19.20.030(2)(a) Maximum units per lot 3 units BMC 19.20.030(2)(a) |
| Subdivision BMC 18.22.010(4) | H | 7 or more BMC 18.12.320 | — | Minimum lot size 8,000 sq ft BMC 19.20.030(2)(a) Minimum lot depth 100 ft BMC 19.20.030(2)(a) Maximum units per lot 3 units BMC 19.20.030(2)(a) |
| Residential cluster BMC 19.23.090 | H | — | The total overall density shall be the same density permitted in the underlying zone. BMC 19.23.010 Minimum parent area 217,800 sq ft BMC 19.23.040 |
Minimum lot size 8,000 sq ft BMC 19.20.030(2)(a) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot is at a cul-de-sac terminus or is a flag lot
- None of these is true:
- Lot is at a cul-de-sac terminus or is a flag lot
- The rear lot line abuts an alley (off-alley lot)
- None of these is true:
- The rear lot line abuts an alley (off-alley lot)