Sign in

MU-1 · Mixed-Use Low

Burien, WA · BMC 19.15.020 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Permanent supportive housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Transitional housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Townhouse—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Apartment—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Senior assisted housing—
HomeA2 ADU—
HomeA2 ADU—
HomeA2 ADU—
—
Co-living housing————
Home✓ ADU—
Emergency housing————
Home✓3 A4 ADU—
Emergency shelter————
HomeA ADU—
Community residential facility————
HomeA ADU—
Enhanced services facility————
HomeA ADU—
Nursing home————
HomeA5 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit BMC 19.15.020(2)(A)
Minimum lot widthNo limit BMC 19.15.020(2)(A)
Minimum lot depthNo limit BMC 19.15.020(2)(A)

3. Building standards

StandardValueExceptions
Front setbackThe minimum front setbacks range from zero to 10 feet, depending upon the block frontage designation and standards provided in BMC 19.47.220 through 19.47.260. BMC 19.15.020(2)(B)(i)
Side setback
  • 15 ft6 BMC 19.15.020(2)(B)(iii)
  • 5 ft7 BMC 19.15.020(2)(B)(iii)
  • 0 ft8 BMC 19.15.020(2)(B)(iii)
  • 5 ft9 BMC 19.15.020(2)(B)(iii)
for Townhouse (2, 3, 4+ units)1
Not set BMC 19.15.020(2)(B)(iii)
for Community residential facility (group living)
Rear setback
  • 15 ft6 BMC 19.15.020(2)(B)(iii)
  • 5 ft7 BMC 19.15.020(2)(B)(iii)
  • 0 ft8 BMC 19.15.020(2)(B)(iii)
  • 5 ft9 BMC 19.15.020(2)(B)(iii)
for Townhouse (2, 3, 4+ units)1
Not set BMC 19.15.020(2)(B)(iii)
for Community residential facility (group living)
Maximum height35 ft BMC 19.15.020(3)
Maximum impervious surfaceNo limit BMC 19.15.020(2)(C)
Minimum parking(employees on the largest shift ÷ 2) + (the smallest of main dwelling units on the lot ÷ 20, beds in the project ÷ 20) spaces BMC 19.20.040(1)
(employees on the largest shift ÷ 2) + (main dwelling units on the lot ÷ 20) spaces BMC 19.20.040(1)
for Permanent supportive housing (1, 2, 3, 4+ units)
1 space per unit BMC 19.20.040(1)
for Townhouse (2, 3, 4+ units)1
  • 0.5 spaces per unit10 BMC 19.20.040(1)
  • 1 space per unit11 BMC 19.20.040(1)
for Apartment (2, 3, 4+ units)
  • 0 spaces per unit12 BMC 19.20.045(1)(A)
  • 0.5 spaces per unit13 BMC 19.20.040(1)
for Senior assisted housing (2, 3, 4+ units)2
  • 0 spaces per sleeping unit14 BMC 19.20.045(1)(D)(iii)
  • 0.25 spaces per sleeping unit15 BMC 19.20.040(1)
for Co-living housing (group living)
0.5 × bedrooms in the whole project spaces BMC 19.20.040(1)
for Community residential facility (group living)
If this code does not specify a parking requirement for a proposed use, the director shall establish the minimum requirement. BMC 19.20.030(2)
for Enhanced services facility (group living)
0.25 spaces per bed BMC 19.20.040(1)
for Nursing home (group living)5
Maximum unit sizeNot set BMC 19.15.020(2)
300 sq ft BMC 19.17.340(2)(A)(i)
for Co-living housing (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 17.10.410; 17.35.120 A up to 4 BMC 17.35.060(2) —
Minimum lot size
No limit BMC 19.15.020(2)(A)
Subdivision BMC 17.40.030; 17.40.040(1) H 2 or more BMC 17.10.440 —
Minimum lot size
No limit BMC 19.15.020(2)(A)
Residential condominium binding site plan BMC 17.50.010(1); 17.50.040(3) H16 —
Maximum units
Not set BMC 17.50
Minimum lot size
No limit BMC 19.15.020(2)(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The lot fronts a pedestrian-oriented street shown in BMC 19.47.220
  2. None of these is true:
    • The site is in the Air and Noise Impact Overlay
  3. All of these are true:
    • Beds in the project is less than 35
    • Main dwelling units on the lot is less than 35
  4. Any of these is true:
    • Beds in the project is at least 35
    • Main dwelling units on the lot is at least 35
  5. None of these is true:
    • The site is in the Air and Noise Impact Overlay
    • The lot fronts a pedestrian-oriented street shown in BMC 19.47.220
  6. The building or portion contains dwelling units whose only solar access (windows) is from the interior or rear of the building, facing the interior property lines
  7. None of these is true:
    • The building or portion contains dwelling units whose only solar access (windows) is from the interior or rear of the building, facing the interior property lines
  8. Townhome units share a common wall along this interior property line
  9. None of these is true:
    • Townhome units share a common wall along this interior property line
  10. Bedrooms in one unit is at most 0
  11. Bedrooms in one unit is more than 0
  12. The site is within a one-quarter mile straight-line distance of transit stops served by transit at least four times an hour for 12 or more hours a day
  13. None of these is true:
    • The site is within a one-quarter mile straight-line distance of transit stops served by transit at least four times an hour for 12 or more hours a day
  14. All of these are true:
    • The site is partially or entirely located within a one-half mile radius of a qualified public transit stop
    None of these is true:
    • The site is entirely within a 1-mile radius of the SeaTac International Airport (no part of it is outside that radius)
  15. Not all of these are true:
    • The site is partially or entirely located within a one-half mile radius of a qualified public transit stop
    • None of these is true:
      • The site is entirely within a 1-mile radius of the SeaTac International Airport (no part of it is outside that radius)
  16. The lot is to be developed for residential condominiums pursuant to Chapter 64.32 RCW