Sign in

MUR-2 · MUR-2 Mixed Use Residential Zone

Burlington, WA · BMC 17.40 · Official code

By right: 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached dwellings
Home✓1 ADU—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Manufactured homes
Home✓1 ADU—
————
Duplex dwellings—
Home✓ ADU—
———
Horizontally attached dwellings——
Home✓ ADU—
Home✓ ADU—
—
Small multiunit buildings——
Home✓ ADU—
Home✓ ADU—
—
Medium multiunit buildings———
Home✓ ADU—
—
Small boarding houses————
Home✓ ADU—
Large boarding houses————
Home✓ ADU—
Large nursing homes————
HomeH3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set BMC 17.40.100
4 units BMC 17.01.050
for Small multiunit buildings (4+ units)
8 units BMC 17.01.050
for Medium multiunit buildings (4+ units)
Minimum unitsNot set BMC 17.40.100
5 units BMC 17.01.050
for Medium multiunit buildings (4+ units)
Minimum lot size1,500 sq ft BMC 17.40.100(A)(1)
Minimum lot width
  • 30 ft4 BMC 17.40.100(A)(2)(a)
  • 15 ft5 BMC 17.40.100(A)(2)(b)
Minimum lot depth60 ft BMC 17.40.100(A)(3)
Minimum densityNot set BMC 17.40.100
  • 1 unit per 4,000 sq ft6 BMC 17.40.090(E)(2)
  • 15 units per acre7 BMC 17.40.090(E)(3)-(4)
for Detached dwellings (2, 3, 4+ units)2
Maximum sleeping unitsNot set BMC 17.40.100
4 sleeping units BMC 17.01.050
for Small boarding houses (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft BMC 17.40.100(C)(1)
Side setback10 ft BMC 17.40.100(C)(3)
Street side setback10 ft BMC 17.40.100(C)(2)
Rear setback5 ft BMC 17.40.100(C)(4)
Building separation30 ft BMC 17.40.100(D)(1)
Maximum height45 ft BMC 17.40.100(F)
Maximum lot coverageNo limit BMC 17.40.100(E)
Maximum impervious surfaceNo limit BMC 17.40.100(E)
Minimum parking
  • 1 space per unit8 BMC 17.85.060(A); Table 17.85.060
  • 2 spaces per unit9 BMC 17.85.060(A); Table 17.85.060
1 + sleeping units in the project spaces BMC 17.85.060(A); Table 17.85.060
for Small boarding houses (group living); Large boarding houses (group living)
(beds in the project ÷ 6) + employees on the largest shift spaces BMC 17.85.060(A); Table 17.85.060
for Large nursing homes (group living)3
Maximum units per building8 units BMC 17.40.100(B)(1)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 16.10.050(A) A up to 9 BMC 16.01.060 —
Minimum lot size
1,500 sq ft BMC 17.40.100(A)(1)
Minimum lot width
  • 30 ft4 BMC 17.40.100(A)(2)(a)
  • 15 ft5 BMC 17.40.100(A)(2)(b)
Minimum lot depth
60 ft BMC 17.40.100(A)(3)
Subdivision BMC 16.10.050(B); 16.10.080(B) H 10 or more BMC 16.01.060 —
Minimum lot size
1,500 sq ft BMC 17.40.100(A)(1)
Minimum lot width
  • 30 ft4 BMC 17.40.100(A)(2)(a)
  • 15 ft5 BMC 17.40.100(A)(2)(b)
Minimum lot depth
60 ft BMC 17.40.100(A)(3)
Testamentary division BMC 16.70.060(A) A
Minimum lots
Not set BMC 16.70
—
Minimum lot size
1,500 sq ft BMC 17.40.100(A)(1); BMC 16.70.080(A)(1)
Minimum lot width
  • 30 ft4 BMC 17.40.100(A)(2)(a)
  • 15 ft5 BMC 17.40.100(A)(2)(b)
Minimum lot depth
60 ft BMC 17.40.100(A)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • All of these are true:
      • Lot is an existing lot
      • Lot area is at most 4,000 sf
    • Dwelling is in a cottage development with a gross density of at least 15 units per acre
    • Dwelling is part of a development with a mix of building types with a gross density of at least 15 units per acre
  2. Any of these is true:
    • Lot is an existing lot
    • Dwelling is in a cottage development with a gross density of at least 15 units per acre
    • Dwelling is part of a development with a mix of building types with a gross density of at least 15 units per acre
  3. Beds in the project is more than 8
  4. None of these is true:
    • Lot has alley access or curb cuts are prohibited by plat notes
  5. Lot has alley access or curb cuts are prohibited by plat notes
  6. None of these is true:
    • Dwelling is in a cottage development with a gross density of at least 15 units per acre
    • Dwelling is part of a development with a mix of building types with a gross density of at least 15 units per acre
  7. Any of these is true:
    • Dwelling is in a cottage development with a gross density of at least 15 units per acre
    • Dwelling is part of a development with a mix of building types with a gross density of at least 15 units per acre
  8. Bedrooms in one unit is at most 2
  9. Bedrooms in one unit is at least 3