RA-1 · RA-1 Residential Attached Zone
Burlington, WA · BMC 17.20 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached dwellings | — | — | — | — | |
| Manufactured homes | — | — | — | — | |
| Duplex dwellings | — | Home✓ ADU— | — | — | — |
| Horizontally attached dwellings | — | — | — | ||
| Small multiunit buildings | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Medium multiunit buildings | — | — | — | — | |
| Small boarding houses | — | — | — | — | Home✓ ADU— |
| Large boarding houses | — | — | — | — | HomeH ADU— |
| Small nursing homes | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set BMC 17.20.090 | 4 units BMC 17.01.050
for Small multiunit buildings (4+ units) 8 units BMC 17.01.050
for Medium multiunit buildings (4+ units)3 |
| Minimum units | Not set BMC 17.20.090 | 5 units BMC 17.01.050
for Medium multiunit buildings (4+ units)3 |
| Minimum lot size | ||
| Minimum lot width | ||
| Minimum lot depth | ||
| Maximum beds | Not set BMC 17.20.090 | 8 beds BMC 17.01.050
for Small nursing homes (group living) |
| Maximum sleeping units | Not set BMC 17.20.090 | 4 sleeping units BMC 17.01.050
for Small boarding houses (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft BMC 17.20.090(B)(3) | |
| Street side setback | 10 ft BMC 17.20.090(B)(2) | |
| Rear setback | 20 ft BMC 17.20.090(B)(4) | |
| Building separation | 10 ft BMC 17.20.090(B)(7)(a) | |
| Maximum height | 35 ft BMC 17.20.090(D) | |
| Maximum lot coverage | 70% BMC 17.20.090(C)(1) | |
| Maximum impervious surface | 70% BMC 17.20.090(C)(1) | |
| Minimum parking | 1 + sleeping units in the project spaces BMC 17.85.060(A); Table 17.85.060
for Small boarding houses (group living); Large boarding houses (group living) (beds in the project ÷ 6) + employees on the largest shift spaces BMC 17.85.060(A); Table 17.85.060
for Small nursing homes (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit BMC 17.20.080(I)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft BMC 17.20.090(B)(3) | |
| Rear setback | 20 ft BMC 17.20.090(B)(4) | |
| Maximum height | 35 ft BMC 17.20.090(D) | |
| Maximum unit size | the largest of 500, the smallest of 1,000, 0.3 × floor area of the main house sq ft BMC 17.20.080(I)(3)(b) | |
| Attached to the main house | Required BMC 17.20.080(I)(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 16.10.050(A) | A | up to 9 BMC 16.01.060 | — | Minimum lot size 1,500 sq ft BMC 17.20.090(A)(1) Minimum lot depth 60 ft BMC 17.20.090(A)(3) |
| Subdivision BMC 16.10.050(B); 16.10.080(B) | H | 10 or more BMC 16.01.060 | — | Minimum lot size 1,500 sq ft BMC 17.20.090(A)(1) Minimum lot depth 60 ft BMC 17.20.090(A)(3) |
| Testamentary division BMC 16.70.060(A) | A | Minimum lots Not set BMC 16.70 |
— | Minimum lot size 1,500 sq ft BMC 17.20.090(A)(1); BMC 16.70.080(A)(1) Minimum lot depth 60 ft BMC 17.20.090(A)(3) |
| Cluster developments BMC 17.20.100; 16.10.050(A) | A | up to 9 BMC 16.01.060 | 38 units per acre BMC 17.20.100(B) | Minimum lot size alternative standards for lot width, lot depth, lot area, building and impervious surface coverage, and property line setbacks may be employed BMC 17.20.100 |
| Cluster developments BMC 17.20.100; 16.10.050(B); 16.10.080(B) | H | 10 or more BMC 16.01.060 | 38 units per acre BMC 17.20.100(B) | Minimum lot size alternative standards for lot width, lot depth, lot area, building and impervious surface coverage, and property line setbacks may be employed BMC 17.20.100 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The ADU is located in a detached accessory building, not within the primary dwelling
- The ADU is located in a detached accessory building, not within the primary dwelling
- Lot is within 1,320 feet (travel distance) of a school, park, bus route, or commercially zoned parcel
- The lot is being created or changed by a land division or boundary line adjustment
- None of these is true:
- The lot is being created or changed by a land division or boundary line adjustment
- All of these are true:
- The lot is being created or changed by a land division or boundary line adjustment
- Lot has alley access or curb cuts are prohibited by plat notes
- All of these are true:
- The lot is being created or changed by a land division or boundary line adjustment
- Lot has alley access or curb cuts are prohibited by plat notes
- None of these is true:
- Lot has alley access or curb cuts are prohibited by plat notes
- Lot has alley access or curb cuts are prohibited by plat notes
- Bedrooms in one unit is at most 2
- Bedrooms in one unit is at least 3