Sign in

ME-NS · North Shore Mixed Employment

Camas, WA · CMC 18.05.050(F); 18.07.030; 18.09.030 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Residence accessory to and connected with a business
HomeH1 ADU✓1
————
Assisted living————
HomeH2 ADU—
Housing for the disabled————
HomeH2 ADU✓2
Nursing, rest, convalescent home————
Home✓ ADU—
Retirement home————
Home✓ ADU—
Residential Treatment Facility————
Home✓3 ADU—
Transitional Housing————
Home✓ ADU—
Permanent Supportive Housing————
HomeH2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit CMC 18.09.030 Table 1
Minimum lot widthNo limit CMC 18.09.030 Table 1
Minimum lot depthNo limit CMC 18.09.030 Table 1

3. Building standards

StandardValueExceptions
Front setbackNo limit CMC 18.09.030 Table 1
Side setbackNo limit CMC 18.09.030 Table 1
Street side setbackNo limit CMC 18.09.030 Table 1
Rear setbackNo limit CMC 18.09.030 Table 1
Maximum height100 ft CMC 18.09.030 Table 1 note 6
Maximum lot coverageNo limit CMC 18.09.030 Table 1
Minimum parkingIn case of a use not specifically mentioned in Section 18.11.130 of this chapter, the requirements for off-street parking facilities shall be determined by the city in accordance with a conditional use permit. Such determination shall be based upon the requirements for the most comparable use listed. CMC 18.11.060
2 spaces per unit CMC 18.11.130
for Residence accessory to and connected with a business (1 unit)1; Retirement home (group living)
(beds in the project ÷ 2) + employees on the largest shift spaces CMC 18.11.130
for Assisted living (group living)2
Minimum open space5% CMC 18.09.030 Table 1 note 5

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units CMC 18.27.040(A)

Building

StandardValueExceptions
Front setbackNo limit CMC 18.27.040(E); 18.09.030 Table 1
Side setback
  • 5 ft4 CMC 18.27.040(E)
  • 10 ft5 CMC 18.27.040(E)
  • No limit6 CMC 18.09.030 Table 1
Rear setback
  • 5 ft7 CMC 18.27.040(E)
  • 0 ft8 CMC 18.27.040(E)
  • No limit6 CMC 18.09.030 Table 1
Maximum height
  • 24 ft9 CMC 18.27.040(D)
  • 100 ft6 CMC 18.09.030 Table 1 note 6
Maximum stories
  • Not set9 CMC 18.27.040(D)
  • Not set6 CMC 18.09.030 Table 1
Minimum parking
  • 0 spaces per unit10 CMC 18.27.040(G)
  • 1 space per unit11 CMC 18.27.040(G)
Maximum unit size1,000 sq ft CMC 18.27.040(F)
Attached to the main houseNot required CMC 18.27.030(A)-(C)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision (short plat) CMC 17.09.020; 18.55.030 A up to 9 CMC 17.09.010(A) —
Minimum lot size
No limit CMC 18.09.030 Table 1
Minimum lot width
No limit CMC 18.09.030 Table 1
Minimum lot depth
No limit CMC 18.09.030 Table 1
Subdivision CMC 17.11.020; 18.55.030 H 10 or more CMC 17.11.010 —
Minimum lot size
No limit CMC 18.09.030 Table 1
Minimum lot width
No limit CMC 18.09.030 Table 1
Minimum lot depth
No limit CMC 18.09.030 Table 1
Binding site plan CMC 17.15.020; 18.55.030 A — —
Minimum lot size
This land division allows certain zoning standards including, for example, minimum parking, setbacks, landscaping, lot area and lot dimension on the individual lots to be modified provided the standards for the entire center are met. CMC 17.15.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Lot area is at least 435,600 sf
    • The project is a mixed use development under a city council approved master plan and development agreement, with at least fifty-one percent of the net developable acreage committed to commercial uses
    • The residence is accessory to and connected with a business on the same site
  2. All of these are true:
    • Lot area is at least 435,600 sf
    • The project is a mixed use development under a city council approved master plan and development agreement, with at least fifty-one percent of the net developable acreage committed to commercial uses
  3. None of these is true:
    • The site is within one thousand feet of a public or private school, public park, public library, another residential treatment facility or a similar use
  4. All of these are true:
    • The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
    None of these is true:
    • The ADU's side lot line is along a flanking street of a corner lot
  5. All of these are true:
    • The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
    • The ADU's side lot line is along a flanking street of a corner lot
  6. None of these is true:
    • The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
  7. All of these are true:
    • The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
    None of these is true:
    • The rear lot line abuts a public alley
  8. All of these are true:
    • The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
    • The rear lot line abuts a public alley
  9. The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
  10. The ADU is located within one-half mile of a major transit stop
  11. None of these is true:
    • The ADU is located within one-half mile of a major transit stop