NC · Neighborhood Commercial
Camas, WA · CMC 18.05.050(A); 18.07.030; 18.09.030 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Residence accessory to and connected with a business | — | — | — | — | |
| Adult family home | — | — | — | — | HomeH ADU✓ |
| Assisted living | — | — | — | — | HomeH ADU— |
| Group home | — | — | — | — | HomeH ADU— |
| Housing for the disabled | — | — | — | — | Home✓ ADU✓ |
| Nursing, rest, convalescent home | — | — | — | — | HomeH ADU— |
| Retirement home | — | — | — | — | HomeH ADU— |
| Residential Treatment Facility | — | — | — | — | |
| Sober Living Homes | — | — | — | — | HomeH ADU✓ |
| Transitional Housing | — | — | — | — | HomeH ADU— |
| Permanent Supportive Housing | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 5,000 sq ft CMC 18.09.030 Table 1 | |
| Minimum lot width | 40 ft CMC 18.09.030 Table 1 | |
| Minimum lot depth | 40 ft CMC 18.09.030 Table 1 | |
| Maximum residents | Not set CMC 18.03.030 | 6 persons CMC 18.03.030
for Adult family home (group living) 8 persons CMC 18.03.030
for Sober Living Homes (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft CMC 18.09.030 Table 1 | |
| Side setback | No limit CMC 18.09.030 Table 1
for Residence accessory to and connected with a business (1 unit)1; Adult family home (group living); Housing for the disabled (group living); Sober Living Homes (group living) | |
| Street side setback | 10 ft CMC 18.09.030 Table 1 note 1 | |
| Rear setback | No limit CMC 18.09.030 Table 1
for Residence accessory to and connected with a business (1 unit)1; Adult family home (group living); Housing for the disabled (group living); Sober Living Homes (group living) | |
| Maximum height | 35 ft CMC 18.09.030 Table 1 | |
| Maximum stories | 2.5 stories CMC 18.09.030 Table 1 | |
| Maximum lot coverage | 85% CMC 18.09.030 Table 1 | |
| Minimum parking | In case of a use not specifically mentioned in Section 18.11.130 of this chapter, the requirements for off-street parking facilities shall be determined by the city in accordance with a conditional use permit. Such determination shall be based upon the requirements for the most comparable use listed. CMC 18.11.060 | 2 spaces per unit CMC 18.11.130
(beds in the project ÷ 2) + employees on the largest shift spaces CMC 18.11.130
for Assisted living (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units CMC 18.27.040(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft CMC 18.27.040(E); 18.09.030 Table 1 | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum stories | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft CMC 18.27.040(F) | |
| Attached to the main house | Not required CMC 18.27.030(A)-(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision (short plat) CMC 17.09.020; 18.55.030 | A | up to 9 CMC 17.09.010(A) | — | Minimum lot size 5,000 sq ft CMC 18.09.030 Table 1 Minimum lot width 40 ft CMC 18.09.030 Table 1 Minimum lot depth 40 ft CMC 18.09.030 Table 1 |
| Subdivision CMC 17.11.020; 18.55.030 | H | 10 or more CMC 17.11.010 | — | Minimum lot size 5,000 sq ft CMC 18.09.030 Table 1 Minimum lot width 40 ft CMC 18.09.030 Table 1 Minimum lot depth 40 ft CMC 18.09.030 Table 1 |
| Binding site plan CMC 17.15.020; 18.55.030 | A | — | — | Minimum lot size This land division allows certain zoning standards including, for example, minimum parking, setbacks, landscaping, lot area and lot dimension on the individual lots to be modified provided the standards for the entire center are met. CMC 17.15.010 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The residence is accessory to and connected with a business on the same site
- None of these is true:
- The site is within one thousand feet of a public or private school, public park, public library, another residential treatment facility or a similar use
- None of these is true:
- The side or rear lot line adjoins a lot in a residential zoning district that the comprehensive plan does not show for future commercial or industrial use
- The side or rear lot line adjoins a lot in a residential zoning district that the comprehensive plan does not show for future commercial or industrial use
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The ADU's side lot line is along a flanking street of a corner lot
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The ADU's side lot line is along a flanking street of a corner lot
- None of these is true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The rear lot line abuts a public alley
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The rear lot line abuts a public alley
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The ADU is located within one-half mile of a major transit stop
- None of these is true:
- The ADU is located within one-half mile of a major transit stop