Sign in

C/MU · Commercial/Mixed Use District

Carbonado, WA · CMC 18.60 · Official code

By right: 1 unit, 2 units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-family
Home✓ ADU✓
————
Dwelling, two-family—
Home✓ ADU—
———
Dwelling, multifamily——
HomeA1 H2 ADU—
HomeA3 H4 H2 ADU—
—
Apartment——
HomeA1 H2 ADU—
HomeA3 H4 H2 ADU—
—
Adult retirement community——
HomeA ADU—
HomeA5 H6 ADU—
—
Adult family home————
HomeA7 H8 ADU—
Assisted living facility————
HomeH ADU—
Group homes————
HomeA7 H8 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size5,000 sq ft CMC 18.25.010
10,000 sq ft CMC 18.25.010
for Dwelling, two-family (2 units)
Minimum lot width50 ft CMC 18.25.010
Maximum density8 units per acre, on the net lot area CMC 18.25.010
Not set CMC 18.25.010; 18.25.010 note 4
for Dwelling, single-family (1 unit); Adult family home (group living)7; Adult family home (group living)8; Assisted living facility (group living); Group homes (group living)7; Group homes (group living)8
8 × 1.5 units per acre, on the net lot area CMC 18.60.050(B)(2); 18.25.010 note 3
for Dwelling, multifamily (3, 4+ units)2; Apartment (3, 4+ units)2; Adult retirement community (3 units); Adult retirement community (4+ units)5; Adult retirement community (4+ units)6
Maximum residentsNot set CMC 18.10.030
6 persons CMC 18.10.030(7)
for Adult family home (group living)7; Adult family home (group living)8

3. Building standards

StandardValueExceptions
Front setback20 ft CMC 18.30.010
Side setback8 ft CMC 18.30.010
Street side setback20 ft CMC 18.30.010
Rear setback
  • 20 ft9 CMC 18.30.010 note 5
  • 25 ft10 CMC 18.30.010
Building separation10 ft CMC 18.30.010 note 4
Maximum height35 ft CMC 18.30.010; 18.60.050(A)
Maximum stories2 stories CMC 18.30.010 note 6
Maximum lot coverage40% CMC 18.30.010; 18.30.010 note 1
Minimum parking2.25 spaces per unit CMC 18.75.040
2 spaces per unit CMC 18.75.040
for Dwelling, single-family (1 unit)
1 space per unit CMC 18.75.040
for Adult retirement community (3 units); Adult retirement community (4+ units)5; Adult retirement community (4+ units)6
In the case of a use not specifically mentioned in this chapter, the requirement for off-street parking facilities shall be determined by the land use administrator. CMC 18.75.050
for Adult family home (group living)7; Adult family home (group living)8
0.75 spaces per unit CMC 18.75.040
for Assisted living facility (group living)
employees on the largest shift + (residents ÷ 5, rounded up) spaces CMC 18.75.040
for Group homes (group living)7; Group homes (group living)8

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit CMC 18.10.030(2)(E)

Building

StandardValueExceptions
Front setback20 ft CMC 18.10.030(2)(F); 18.30.010
Side setback8 ft CMC 18.10.030(2)(F); 18.30.010
Rear setback
  • 20 ft9 CMC 18.30.010 note 5
  • 25 ft10 CMC 18.30.010
Maximum height35 ft CMC 18.10.030(2)(F); 18.30.010
Maximum stories2 stories CMC 18.10.030(2)(F); 18.30.010 note 6
Minimum parking1 × bedrooms in one ADU spaces CMC 18.10.030(2)(C)
Maximum unit size0.6 × floor area of the main house sq ft CMC 18.10.030(2)(B)
Attached to the main houseNot required CMC 18.10.030(2)
Owner lives on siteRequired CMC 18.10.030(2)(A)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 17.20.050 A up to 4 CMC 17.20.020 —
Minimum lot size
5,000 sq ft CMC 18.25.010
Minimum lot width
50 ft CMC 18.25.010
Subdivision CMC 17.15.020 H 5 or more CMC 17.10.080 —
Minimum lot size
5,000 sq ft CMC 18.25.010
Minimum lot width
50 ft CMC 18.25.010
Binding site plans CMC 17.35.010 — — — —

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Residential development on upper floors of a building where the first floor is used primarily for retail or personal service establishments
  2. Residential development on upper floors of a building where the first floor is used primarily for retail or personal service establishments
  3. All of these are true:
    • Main dwelling units on the lot is at most 5
    None of these is true:
    • Residential development on upper floors of a building where the first floor is used primarily for retail or personal service establishments
  4. All of these are true:
    • Main dwelling units on the lot is more than 5
    None of these is true:
    • Residential development on upper floors of a building where the first floor is used primarily for retail or personal service establishments
  5. Main dwelling units on the lot is at most 5
  6. Main dwelling units on the lot is more than 5
  7. None of these is true:
    • The project needs major site plan approval under CMC 14.25.020(C) (e.g. new nonresidential construction over 2,000 square feet, or any development not classified as a minor site plan)
  8. The project needs major site plan approval under CMC 14.25.020(C) (e.g. new nonresidential construction over 2,000 square feet, or any development not classified as a minor site plan)
  9. The CMU or CF lot abuts a residential district
  10. None of these is true:
    • The CMU or CF lot abuts a residential district