Sign in

LBD · Limited business district (LBD)

Centralia, WA · CMC 20.33; 20.11.020 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU✓1
————
Live work units—Commercial located on the ground floor, residential units on upper floor(s)
Home✓ ADU✓1
————
Duplex—
Home✓ ADU✓1
———
Twinhome—
Home✓ ADU✓1
———
Triplex——
Home✓ ADU✓1
——
Townhouse development——
Home✓ ADU✓1
Home✓ ADU✓1
—
Fourplex———
Home✓ ADU✓1
—
Multiple-family dwelling———
Home✓ ADU✓1
—
Planned unit development (PUD)———
HomeH ADU✓1
—
Adult family home with 8 or fewer residents————
Home✓ ADU✓1
Assisted living facility————
HomeH ADU—
Boarding houses, hostel, etc.————
HomeH2 ADU—
Emergency housing/homeless housing (indoors only)————
Home✓3 ADU—
Emergency shelter for domestic violence————
HomeH4 ADU—
Permanent supportive housing————
Home✓5 ADU—
Transitional housing————
Home✓5 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set CMC 20.33
4 units CMC 20.06.284.5
for Fourplex (4+ units)
Minimum units4 units CMC 20.06.284.5
5 units CMC 20.06.285
for Multiple-family dwelling (4+ units)
3 units CMC 20.61.020(A)
for Townhouse development (4+ units)
Not set CMC 20.33
for Planned unit development (PUD) (4+ units)
Minimum lot size10,000 sq ft CMC 20.33.050(A)
12,000 sq ft CMC 20.33.050(A)
for Triplex (3 units)
1,600 × main dwelling units on the lot sq ft CMC 20.61.040(B)
for Townhouse development (3, 4+ units)
16,000 sq ft CMC 20.33.050(A)
for Fourplex (4+ units)
Not set CMC 20.33.050(A)
for Multiple-family dwelling (4+ units)
4,000 sq ft CMC 20.60.100(A)
for Planned unit development (PUD) (4+ units)
Minimum lot width50 ft CMC 20.33.050(B)
Not set CMC 20.60.050(A)(2); 20.60.100
for Planned unit development (PUD) (4+ units)
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Minimum density0 units per acre CMC 20.33.100
Not set CMC 20.33.100
for Adult family home with 8 or fewer residents (group living); Assisted living facility (group living); Boarding houses, hostel, etc. (group living)2; Emergency housing/homeless housing (indoors only) (group living)3; Emergency shelter for domestic violence (group living)4; Permanent supportive housing (group living)5; Transitional housing (group living)5
Maximum density8 units per acre CMC 20.33.050(A); 20.33.100
  • 8 units per acre8 CMC 20.61.040(A); 20.33.050(A); 20.33.100
  • 8 × 1.2 units per acre9 CMC 20.61.040(A); 20.61.045(C); 20.33.050(A); 20.33.100
for Townhouse development (3, 4+ units)
  • 8 units per acre10 CMC 20.60.140(B)(1); 20.33.050(A); 20.33.100
  • 8 × 1.2 units per acre, a fraction of 0.5 or more rounds up11 CMC 20.60.140(B)(1)-(2); 20.33.050(A); 20.33.100
for Planned unit development (PUD) (4+ units)
Not set CMC 20.33.050(A); 20.33.100
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)3; Permanent supportive housing (group living)5; Transitional housing (group living)5
Minimum development sizeNot set CMC 20.33.050
87,120 sq ft CMC 20.60.080
for Planned unit development (PUD) (4+ units)
Maximum residentsNot set CMC 20.11.020(B)
6 persons CMC 20.06.095
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)3
10 persons CMC 20.06.150
for Boarding houses, hostel, etc. (group living)2
80 persons CMC 20.62.030(A)
for Emergency shelter for domestic violence (group living)4

3. Building standards

StandardValueExceptions
Front setback20 ft CMC 20.33.050(E)
10 ft CMC 20.60.110(B)(1)
for Planned unit development (PUD) (4+ units)
Side setback10 ft CMC 20.33.050(C)
5 ft CMC 20.60.110(B)(5)
for Planned unit development (PUD) (4+ units)
Street side setback15 ft CMC 20.33.050(H)
Not set CMC 20.60.110
for Planned unit development (PUD) (4+ units)
Rear setback25 ft CMC 20.33.050(D)
15 ft CMC 20.61.040(F)
for Townhouse development (3, 4+ units)
10 ft CMC 20.60.110(B)(6)
for Planned unit development (PUD) (4+ units)
Building separationNot set CMC 20.33.050
10 ft CMC 20.61.040(I)
for Townhouse development (3, 4+ units); Planned unit development (PUD) (4+ units)
Maximum height40 ft CMC 20.33.050(G)
Maximum impervious surface54% CMC 20.33.050(F)
Minimum parking2 spaces per unit CMC 20.72.030(B); 20.33.060
The total requirements for off-street parking shall be the sum of the requirements for the several uses computed separately CMC 20.72.030(C); 20.33.060
for Live work units—Commercial located on the ground floor, residential units on upper floor(s) (1 unit)
  • 1 + (1 ÷ 3) spaces per unit12 CMC 20.72.030(B); 20.33.060
  • 2 + (1 ÷ 3) spaces per unit13 CMC 20.72.030(B); 20.33.060
for Multiple-family dwelling (4+ units)
The community development department and city engineer shall determine which of the uses is most similar based upon staff experience with various uses and information provided by the applicant CMC 20.72.030(C); 20.33.060
for Adult family home with 8 or fewer residents (group living)
(main dwelling units on the lot ÷ 3) + (main dwelling units on the lot ÷ 5) + employees on the largest shift spaces CMC 20.72.030(B); 20.33.060
for Assisted living facility (group living)
1 space per sleeping unit CMC 20.72.030(C); 20.33.060
for Boarding houses, hostel, etc. (group living)2
(0.5 × (floor area of all units ÷ 1,000)) + employees on the largest shift spaces CMC 20.72.030(B); 20.33.060
for Emergency shelter for domestic violence (group living)4
1.5 spaces per unit CMC 20.72.030(B); 20.33.060
for Permanent supportive housing (group living)5; Transitional housing (group living)5
Minimum open space15% CMC 20.33.070; 20.50.050(B)(1)
30% CMC 20.60.140(A)(1)
for Planned unit development (PUD) (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units CMC 20.21.040(A)

Building

StandardValueExceptions
Front setback20 ft CMC 20.21.040(D)(5)
Side setback
  • 10 ft14 CMC 20.21.040(D)(5); 20.33.050(C)
  • 5 ft15 CMC 20.21.040(D)(5)
Rear setback5 ft CMC 20.21.040(D)(5)
Maximum height40 ft CMC 20.33.050(G)
Minimum parking
  • 0 spaces per unit16 CMC 20.21.040(D)(6)
  • 1 space per unit17 CMC 20.21.040(D)(6); 20.72.030(B)
Attached to the main houseNot required CMC 20.21.040(A)
Owner lives on siteNot required CMC 20.21.040(E)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 19.16.010(D); 19.16.020(B)(4) A up to 9 CMC 19.04.020; 19.16.010(A) —
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.18 CMC 20.33.100
  • 10,000 sq ft19 CMC 20.33.050(A)
Minimum lot width
50 ft CMC 20.33.050(B)
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Subdivision CMC 19.12.050(A); 19.12.060; 20.02.040(D) H 5 or more CMC 19.04.020; 19.12.010(A) —
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.18 CMC 20.33.100
  • 10,000 sq ft19 CMC 20.33.050(A)
Minimum lot width
50 ft CMC 20.33.050(B)
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Large lot subdivision CMC 19.18.010(D) A
Maximum lots
Not set CMC 19.18.010(A)
—
Minimum lot size
217,800 sq ft CMC 19.18.010(A)
Minimum lot width
50 ft CMC 20.33.050(B)
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Boundary line adjustment CMC 19.20.020(D); 19.20.030(B) A
Maximum lots
which does not create an additional lot, tract, parcel, building site, or division, nor creates any lot, tract, parcel, building site, or division which contains insufficient area or dimension to meet the minimum requirements for width or area for a building site CMC 19.04.020; 19.20.020(C)
—
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.18 CMC 20.33.100
  • 10,000 sq ft19 CMC 20.33.050(A)
Minimum lot width
50 ft CMC 20.33.050(B)
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Binding site plan CMC 19.28.070; 19.28.080; 20.02.040(D) H
Maximum lots
Not set CMC 19.28.030
—
Minimum lot size
Design and Development Requirements. Design and development standards of this title will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this chapter. CMC 19.28.050(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to on-site sewage system infrastructure
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to critical areas (CMC Title 16) or their buffer areas
    • Development at the ADU location is restricted under federal, state, or local law because of other unsuitable physical characteristics of the property
  2. All of these are true:
    • The residence is owner-occupied (the fee owner, contract purchaser or life tenant resides there more than eight months per calendar year)
    • The boarding house or hostel is located in the principal residence on the premises, not in another structure
    • The use does not require exterior structural alterations of the residence
  3. All of these are true:
    • Residents is at most 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  4. All of these are true:
    • Residents is at least 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  5. None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  6. The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  7. None of these is true:
    • The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  8. None of these is true:
    • The project gets a townhouse density bonus approved by the site plan review committee
  9. The project gets a townhouse density bonus approved by the site plan review committee
  10. None of these is true:
    • The project gets a PUD density bonus approved by the city council
  11. The project gets a PUD density bonus approved by the city council
  12. Bedrooms in one unit is at most 0
  13. Bedrooms in one unit is more than 0
  14. The lot is a corner lot
  15. None of these is true:
    • The lot is a corner lot
  16. The accessory dwelling unit is within one-half mile walking distance of a major transit stop
  17. None of these is true:
    • The accessory dwelling unit is within one-half mile walking distance of a major transit stop
  18. All of these are true:
    • The parcel is unplatted
    • Lot area is less than 43,560 sf
  19. Not all of these are true:
    • The parcel is unplatted
    • Lot area is less than 43,560 sf