Sign in

R15 · Medium-high-density residential district (R:15)

Centralia, WA · CMC 20.21; 20.11.010 · Official code

By right: 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Triplex——
Home✓ ADU✓1
——
Townhouse development——
Home✓ ADU✓1
Home✓ ADU✓1
—
Fourplex———
Home✓ ADU✓1
—
Multiple-family dwelling———
Home✓ ADU✓1
—
Planned unit development (PUD)———
HomeH ADU✓1
—
Mobile home/manufactured home park———
Home✓ ADU—
—
Adult family home with 8 or fewer residents————
Home✓ ADU✓1
Assisted living facility————
HomeH ADU—
Boarding houses, hostel, etc.————
Home✓ ADU—
Dormitory for students————
HomeH ADU—
Emergency housing/homeless housing (indoors only)————
Home✓2 ADU—
Emergency shelter for domestic violence————
Home✓3 H4 ADU—
Foster home————
Home✓ ADU✓1
Nursing home/convalescent care facility/long-term care facility————
HomeH ADU—
Permanent supportive housing————
Home✓5 ADU—
Transitional housing————
Home✓5 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set CMC 20.21
4 units CMC 20.06.284.5
for Fourplex (4+ units)
Minimum unitsNot set CMC 20.21
4 units CMC 20.06.284.5
for Fourplex (4+ units)
5 units CMC 20.06.285
for Multiple-family dwelling (4+ units)
3 units CMC 20.61.020(A)
for Townhouse development (4+ units)
Minimum lot size6,000 sq ft CMC 20.21.050
1,600 × main dwelling units on the lot sq ft CMC 20.61.040(B)
for Townhouse development (3, 4+ units)
10,000 sq ft CMC 20.21.050
for Fourplex (4+ units); Multiple-family dwelling (4+ units)
4,000 sq ft CMC 20.60.100(A)
for Planned unit development (PUD) (4+ units)
4,000 × main dwelling units on the lot sq ft CMC 20.63.050(A)
for Mobile home/manufactured home park (4+ units)
Minimum lot width40 ft CMC 20.21.050
Not set CMC 20.60.050(A)(2); 20.60.100
for Planned unit development (PUD) (4+ units)
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Minimum densityNot set CMC 20.21.050
0 units per acre CMC 20.21.050
for Triplex (3 units); Townhouse development (3, 4+ units); Fourplex (4+ units); Multiple-family dwelling (4+ units); Planned unit development (PUD) (4+ units); Mobile home/manufactured home park (4+ units)
Maximum density15 units per acre CMC 20.21.050
  • 15 units per acre8 CMC 20.61.040(A); 20.21.050
  • 15 × 1.2 units per acre9 CMC 20.61.040(A); 20.61.045(C); 20.21.050
for Townhouse development (3, 4+ units)
  • 15 units per acre10 CMC 20.60.140(B)(1); 20.21.050
  • 15 × 1.2 units per acre, a fraction of 0.5 or more rounds up11 CMC 20.60.140(B)(1)-(2); 20.21.050
for Planned unit development (PUD) (4+ units)
8 units per acre CMC 20.63.040
for Mobile home/manufactured home park (4+ units)
Not set CMC 20.21.050
for Adult family home with 8 or fewer residents (group living); Boarding houses, hostel, etc. (group living); Emergency housing/homeless housing (indoors only) (group living)2; Emergency shelter for domestic violence (group living)3; Foster home (group living)
Minimum development sizeNot set CMC 20.21.050
87,120 sq ft CMC 20.60.080
for Planned unit development (PUD) (4+ units)
Maximum residentsNot set CMC 20.11.010(B)
6 persons CMC 20.06.095
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)2
10 persons CMC 20.06.150
for Boarding houses, hostel, etc. (group living)
9 persons CMC 20.11.010(B)
for Emergency shelter for domestic violence (group living)3
80 persons CMC 20.62.030(A)
for Emergency shelter for domestic violence (group living)4

3. Building standards

StandardValueExceptions
Front setback20 ft CMC 20.21.060
10 ft CMC 20.60.110(B)(1)
for Planned unit development (PUD) (4+ units)
Side setback5 ft CMC 20.21.060
Street side setback15 ft CMC 20.21.060
Not set CMC 20.60.110
for Planned unit development (PUD) (4+ units)
Rear setback25 ft CMC 20.21.060
15 ft CMC 20.61.040(F)
for Townhouse development (3, 4+ units)
10 ft CMC 20.60.110(B)(6)
for Planned unit development (PUD) (4+ units)
Building separationNot set CMC 20.21.060
10 ft CMC 20.61.040(I)
for Townhouse development (3, 4+ units); Planned unit development (PUD) (4+ units)
15 ft CMC 20.63.050(F)
for Mobile home/manufactured home park (4+ units)
Maximum height60 ft CMC 20.21.070
Maximum lot coverage65% CMC 20.21.050
50% CMC 20.63.050(E)
for Mobile home/manufactured home park (4+ units)
Minimum parking2 spaces per unit CMC 20.72.030(B); 20.21.090
  • 1 + (1 ÷ 3) spaces per unit12 CMC 20.72.030(B); 20.21.090
  • 2 + (1 ÷ 3) spaces per unit13 CMC 20.72.030(B); 20.21.090
for Multiple-family dwelling (4+ units)
The community development department and city engineer shall determine which of the uses is most similar based upon staff experience with various uses and information provided by the applicant CMC 20.72.030(C); 20.21.090
for Adult family home with 8 or fewer residents (group living); Dormitory for students (group living); Foster home (group living)
(main dwelling units on the lot ÷ 3) + (main dwelling units on the lot ÷ 5) + employees on the largest shift spaces CMC 20.72.030(B); 20.21.090
for Assisted living facility (group living)
1 space per sleeping unit CMC 20.72.030(C); 20.21.090
for Boarding houses, hostel, etc. (group living)
(0.5 × (floor area of all units ÷ 1,000)) + employees on the largest shift spaces CMC 20.72.030(B); 20.21.090
for Emergency shelter for domestic violence (group living)3; Emergency shelter for domestic violence (group living)4
(residents ÷ 3) + employees on the largest shift spaces CMC 20.72.030(C); 20.21.090
for Nursing home/convalescent care facility/long-term care facility (group living)
1.5 spaces per unit CMC 20.72.030(B); 20.21.090
for Permanent supportive housing (group living)5; Transitional housing (group living)5
Maximum lot sizeNot set CMC 20.21.050
871,200 sq ft CMC 20.63.040
for Mobile home/manufactured home park (4+ units)
Minimum open spaceNot set CMC 20.50.050(A)
  • 30%14 CMC 20.21.100; 20.50.050(A)(1)
  • Not set15 CMC 20.50.050(A)
for Multiple-family dwelling (4+ units); Townhouse development (4+ units)
30% CMC 20.60.140(A)(1)
for Planned unit development (PUD) (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units CMC 20.21.040(A)

Building

StandardValueExceptions
Front setback20 ft CMC 20.21.040(D)(5)
Side setback5 ft CMC 20.21.040(D)(5)
Rear setback5 ft CMC 20.21.040(D)(5)
Maximum height
  • 30 ft16 CMC 20.21.070
  • 60 ft17 CMC 20.21.070
Minimum parking
  • 0 spaces per unit18 CMC 20.21.040(D)(6)
  • 1 space per unit19 CMC 20.21.040(D)(6); 20.72.030(B)
Attached to the main houseNot required CMC 20.21.040(A)
Owner lives on siteNot required CMC 20.21.040(E)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 19.16.010(D); 19.16.020(B)(4) A up to 9 CMC 19.04.020; 19.16.010(A) —
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.20 CMC 20.21.120
  • 6,000 sq ft21 CMC 20.21.050
Minimum lot width
40 ft CMC 20.21.050
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Subdivision CMC 19.12.050(A); 19.12.060; 20.02.040(D) H 5 or more CMC 19.04.020; 19.12.010(A) —
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.20 CMC 20.21.120
  • 6,000 sq ft21 CMC 20.21.050
Minimum lot width
40 ft CMC 20.21.050
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Large lot subdivision CMC 19.18.010(D) A
Maximum lots
Not set CMC 19.18.010(A)
—
Minimum lot size
217,800 sq ft CMC 19.18.010(A)
Minimum lot width
40 ft CMC 20.21.050
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Boundary line adjustment CMC 19.20.020(D); 19.20.030(B) A
Maximum lots
which does not create an additional lot, tract, parcel, building site, or division, nor creates any lot, tract, parcel, building site, or division which contains insufficient area or dimension to meet the minimum requirements for width or area for a building site CMC 19.04.020; 19.20.020(C)
—
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.20 CMC 20.21.120
  • 6,000 sq ft21 CMC 20.21.050
Minimum lot width
40 ft CMC 20.21.050
Minimum frontage
  • 20 ft6 CMC 19.32.030(B)
  • Not set7 CMC 19.32.030(A)
Binding site plan CMC 19.28.070; 19.28.080; 20.02.040(D)Only for: Mobile home/manufactured home park H
Maximum lots
Not set CMC 19.28.030
—
Minimum lot size
Design and Development Requirements. Design and development standards of this title will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this chapter. CMC 19.28.050(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to on-site sewage system infrastructure
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to critical areas (CMC Title 16) or their buffer areas
    • Development at the ADU location is restricted under federal, state, or local law because of other unsuitable physical characteristics of the property
  2. All of these are true:
    • Residents is at most 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  3. All of these are true:
    • Residents is less than 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  4. All of these are true:
    • Residents is at least 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  5. None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  6. The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  7. None of these is true:
    • The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  8. None of these is true:
    • The project gets a townhouse density bonus approved by the site plan review committee
  9. The project gets a townhouse density bonus approved by the site plan review committee
  10. None of these is true:
    • The project gets a PUD density bonus approved by the city council
  11. The project gets a PUD density bonus approved by the city council
  12. Bedrooms in one unit is at most 0
  13. Bedrooms in one unit is more than 0
  14. Main dwelling units on the lot is more than 5
  15. Main dwelling units on the lot is at most 5
  16. The accessory dwelling unit is in an accessory building (detached from the primary dwelling)
  17. None of these is true:
    • The accessory dwelling unit is in an accessory building (detached from the primary dwelling)
  18. The accessory dwelling unit is within one-half mile walking distance of a major transit stop
  19. None of these is true:
    • The accessory dwelling unit is within one-half mile walking distance of a major transit stop
  20. All of these are true:
    • The parcel is unplatted
    • Lot area is less than 43,560 sf
  21. Not all of these are true:
    • The parcel is unplatted
    • Lot area is less than 43,560 sf