Sign in

R5A · Rural residential district (R-5A)

Centralia, WA · CMC 20.21; 20.11.010 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU✓1
————
Manufactured home
Home✓2 ADU✓3
————
Adult family home with 8 or fewer residents————
Home✓ ADU✓1
Assisted living facility————
HomeH ADU—
Boarding houses, hostel, etc.————
HomeH4 ADU—
Emergency housing/homeless housing (indoors only)————
Home✓5 ADU—
Emergency shelter for domestic violence————
Home✓6 H7 ADU—
Foster home————
Home✓ ADU✓1
Nursing home/convalescent care facility/long-term care facility————
HomeH ADU—
Permanent supportive housing————
Home✓8 ADU—
Transitional housing————
Home✓8 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size217,800 sq ft CMC 20.21.050
Minimum lot width100 ft CMC 20.21.050
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Minimum densityNot set CMC 20.21.050
0 units per acre CMC 20.21.050
for Single-family dwelling (1 unit); Manufactured home (1 unit)2
Maximum density0.2 units per acre CMC 20.21.050
Not set CMC 20.21.050
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)5; Emergency shelter for domestic violence (group living)6; Foster home (group living); Permanent supportive housing (group living)8; Transitional housing (group living)8
Maximum residentsNot set CMC 20.11.010(B)
6 persons CMC 20.06.095
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)5
10 persons CMC 20.06.150
for Boarding houses, hostel, etc. (group living)4
9 persons CMC 20.11.010(B)
for Emergency shelter for domestic violence (group living)6
80 persons CMC 20.62.030(A)
for Emergency shelter for domestic violence (group living)7
Occupancy Limits. Permanent supportive and transitional housing shall meet the minimum area per occupant established by the building regulations for a single-family detached residence. CMC 20.62.040(A)(1)(a)
for Permanent supportive housing (group living)8; Transitional housing (group living)8

3. Building standards

StandardValueExceptions
Front setback20 ft CMC 20.21.060
Side setback10 ft CMC 20.21.060
Street side setback15 ft CMC 20.21.060
Rear setback25 ft CMC 20.21.060
Maximum height35 ft CMC 20.21.070
Maximum lot coverage10% CMC 20.21.050
Minimum parking2 spaces per unit CMC 20.72.030(B); 20.21.090
The community development department and city engineer shall determine which of the uses is most similar based upon staff experience with various uses and information provided by the applicant CMC 20.72.030(C); 20.21.090
for Adult family home with 8 or fewer residents (group living); Foster home (group living)
(main dwelling units on the lot ÷ 3) + (main dwelling units on the lot ÷ 5) + employees on the largest shift spaces CMC 20.72.030(B); 20.21.090
for Assisted living facility (group living)
1 space per sleeping unit CMC 20.72.030(C); 20.21.090
for Boarding houses, hostel, etc. (group living)4
(0.5 × (floor area of all units ÷ 1,000)) + employees on the largest shift spaces CMC 20.72.030(B); 20.21.090
for Emergency shelter for domestic violence (group living)6; Emergency shelter for domestic violence (group living)7
(residents ÷ 3) + employees on the largest shift spaces CMC 20.72.030(C); 20.21.090
for Nursing home/convalescent care facility/long-term care facility (group living)
1.5 spaces per unit CMC 20.72.030(B); 20.21.090
for Permanent supportive housing (group living)8; Transitional housing (group living)8

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units CMC 20.21.040(A)

Building

StandardValueExceptions
Front setback20 ft CMC 20.21.040(D)(5)
Side setback
  • 10 ft11 CMC 20.21.040(D)(5); 20.21.060
  • 5 ft12 CMC 20.21.040(D)(5)
Rear setback5 ft CMC 20.21.040(D)(5)
Maximum height
  • 30 ft13 CMC 20.21.070
  • 35 ft14 CMC 20.21.070
Minimum parking
  • 0 spaces per unit15 CMC 20.21.040(D)(6)
  • 1 space per unit16 CMC 20.21.040(D)(6); 20.72.030(B)
Attached to the main houseNot required CMC 20.21.040(A)
Owner lives on siteNot required CMC 20.21.040(E)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 19.16.010(D); 19.16.020(B)(4) A up to 9 CMC 19.04.020; 19.16.010(A) —
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.17 CMC 20.21.120
  • 217,800 sq ft18 CMC 20.21.050
Minimum lot width
100 ft CMC 20.21.050
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Subdivision CMC 19.12.050(A); 19.12.060; 20.02.040(D) H 5 or more CMC 19.04.020; 19.12.010(A) —
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.17 CMC 20.21.120
  • 217,800 sq ft18 CMC 20.21.050
Minimum lot width
100 ft CMC 20.21.050
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Large lot subdivision CMC 19.18.010(D) A
Maximum lots
Not set CMC 19.18.010(A)
—
Minimum lot size
217,800 sq ft CMC 19.18.010(A)
Minimum lot width
100 ft CMC 20.21.050
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Boundary line adjustment CMC 19.20.020(D); 19.20.030(B) A
Maximum lots
which does not create an additional lot, tract, parcel, building site, or division, nor creates any lot, tract, parcel, building site, or division which contains insufficient area or dimension to meet the minimum requirements for width or area for a building site CMC 19.04.020; 19.20.020(C)
—
Minimum lot size
  • For unplatted parcels of less than one acre, properties may be divided into the maximum number of lots the minimum lot size will permit, provided said lot has infrastructure available to it to support the lots being created and provided created lots are not less than the average lot size of adjacent developed lots.17 CMC 20.21.120
  • 217,800 sq ft18 CMC 20.21.050
Minimum lot width
100 ft CMC 20.21.050
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to on-site sewage system infrastructure
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to critical areas (CMC Title 16) or their buffer areas
    • Development at the ADU location is restricted under federal, state, or local law because of other unsuitable physical characteristics of the property
  2. The manufactured home has not been previously sited and used for residential or commercial purposes (except as a display model)
  3. All of these are true:
    • The manufactured home has not been previously sited and used for residential or commercial purposes (except as a display model)
    None of these is true:
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to on-site sewage system infrastructure
    • Development at the ADU location is restricted under federal, state, or local law because of physical proximity to critical areas (CMC Title 16) or their buffer areas
    • Development at the ADU location is restricted under federal, state, or local law because of other unsuitable physical characteristics of the property
  4. All of these are true:
    • The residence is owner-occupied (the fee owner, contract purchaser or life tenant resides there more than eight months per calendar year)
    • The boarding house or hostel is located in the principal residence on the premises, not in another structure
    • The use does not require exterior structural alterations of the residence
  5. All of these are true:
    • Residents is at most 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  6. All of these are true:
    • Residents is less than 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  7. All of these are true:
    • Residents is at least 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  8. None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  9. The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  10. None of these is true:
    • The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  11. The lot is a corner lot
  12. None of these is true:
    • The lot is a corner lot
  13. The accessory dwelling unit is in an accessory building (detached from the primary dwelling)
  14. None of these is true:
    • The accessory dwelling unit is in an accessory building (detached from the primary dwelling)
  15. The accessory dwelling unit is within one-half mile walking distance of a major transit stop
  16. None of these is true:
    • The accessory dwelling unit is within one-half mile walking distance of a major transit stop
  17. All of these are true:
    • The parcel is unplatted
    • Lot area is less than 43,560 sf
  18. Not all of these are true:
    • The parcel is unplatted
    • Lot area is less than 43,560 sf