Sign in

CO - Commercial Office/Mixed Use · C-O – Commercial Office/Mixed Use

Chehalis, WA · CMC 17.57 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Apartment house——
HomeH1 ADU—
HomeH1 ADU—
—
Dwelling, multiple unit——
HomeH1 ADU—
HomeH1 ADU—
—
Convalescent center————
HomeH ADU—
Group care facility————
HomeH ADU—
Rehabilitation center (halfway house)————
HomeH ADU—
Rehabilitation center (Oxford house)————
HomeH ADU—
Residential group care facility for 6 to 16 persons————
HomeH ADU—
Retirement center————
HomeH ADU—
Retirement home————
HomeH ADU—
Indoor emergency housing/shelter————
Home✓2 H3 ADU—
Shelter, transient homeless————
Home✓2 H3 ADU—
Nursing home (6 or more ambulatory persons)————
HomeH ADU—
Nursing home (6 or more nonambulatory persons)————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set CMC 17.57.020
5,000 sq ft CMC 17.57.020
for Indoor emergency housing/shelter (group living)2; Shelter, transient homeless (group living)2
Minimum frontageNot set CMC 17.57.020
50 ft CMC 17.57.020
for Indoor emergency housing/shelter (group living)2; Shelter, transient homeless (group living)2
Minimum density0 units per acre CMC 17.57.020
Maximum densityNot set CMC 17.57.020; 17.78.020 (R143)
  • 24 units per acre4 CMC 17.57.020
  • 24 × 1.1 units per acre5 CMC 17.57.020; 17.78.020 (note 20)(1)
for Apartment house (3, 4+ units)1; Dwelling, multiple unit (3, 4+ units)1
Maximum residentsNot set CMC 17.78.020 (R143)
16 persons CMC 17.78.020 (R401)
for Residential group care facility for 6 to 16 persons (group living)

3. Building standards

StandardValueExceptions
Front setback5 ft CMC 17.57.020
Side setback3 ft CMC 17.57.020
Street side setback5 ft CMC 17.57.020
Rear setback
  • 3 ft6 CMC 17.57.020
  • 0 ft7 CMC 17.57.020
Maximum height35 ft CMC 17.57.020
Maximum lot coverage100% CMC 17.57.020
Minimum parking1 space per resident CMC 17.78.020 (R143); 17.84.010(B)
2 spaces per unit CMC 17.78.020 (R121); 17.84.010(B)
for Apartment house (3, 4+ units)1; Dwelling, multiple unit (3, 4+ units)1
1 space per bed CMC 17.78.020 (R401); 17.84.010(B)
for Residential group care facility for 6 to 16 persons (group living); Nursing home (6 or more nonambulatory persons) (group living)
As required for the individual occupancies CMC 17.78.020 (R012); 17.78.020 (note 8)
for Retirement center (group living)
  • 0.25 spaces per bed8 CMC 17.78.020 (R147); 17.84.010(B)
  • beds in the project ÷ 3 spaces9 CMC 17.78.020 (R147); 17.84.010(B)
for Indoor emergency housing/shelter (group living)2; Indoor emergency housing/shelter (group living)3
beds in the project ÷ 3 spaces CMC 17.78.020 (R148); 17.84.010(B)
for Shelter, transient homeless (group living)2; Shelter, transient homeless (group living)3; Nursing home (6 or more ambulatory persons) (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 17.09.030; 17.12A.200(A); 17.12A.200(E)(1) A 2 to 4 CMC 17.12A.010(B)(1); CMC 17.09.030 —
Minimum lot size
5,000 sq ft CMC 17.57.020; 17.12A.010(I)(2)
Minimum lot width
Not set CMC 17.57.020; 17.06.450
Minimum lot depth
Not set CMC 17.57.020
Minimum frontage
50 ft CMC 17.57.020
Maximum units per lot
Not set CMC 17.57.020; 17.12A.010(I)
Short subdivision CMC 17.09.030; 17.12A.200(A); 17.12A.200(E)(1)(d) H 5 to 9 CMC 17.09.030; CMC 17.12A.200(A); 17.12A.010(F) —
Minimum lot size
5,000 sq ft CMC 17.57.020; 17.12A.010(I)(2)
Minimum lot width
Not set CMC 17.57.020; 17.06.450
Minimum lot depth
Not set CMC 17.57.020
Minimum frontage
50 ft CMC 17.57.020
Maximum units per lot
Not set CMC 17.57.020; 17.12A.010(I)
Subdivision CMC 17.09.030; 17.12A.100(D) H 10 or more CMC 17.12A.010(F)
Minimum average lot size
5,000 sq ft CMC 17.57.020; 17.12A.010(I)(1)(a)
Minimum lot size
5,000 sq ft CMC 17.57.020; 17.12A.010(I)(1)
Minimum lot width
Not set CMC 17.57.020; 17.06.450
Minimum lot depth
Not set CMC 17.57.020
Minimum frontage
50 ft CMC 17.57.020
Maximum units per lot
Not set CMC 17.57.020; 17.12A.010(I)
Binding site plan CMC 17.09.030; 17.09.195(A); 17.12A.300(A) H
Maximum lots
Not set CMC 17.12A.300; 17.09.195
—
Minimum lot size
No limit CMC 17.12A.300(B)
Minimum lot width
No limit CMC 17.12A.300(B)
Minimum lot depth
No limit CMC 17.12A.300(B)
Minimum frontage
No limit CMC 17.12A.300(B)
Maximum units per lot
Not set CMC 17.12A.300(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Dwellings are located above a commercial ground floor
  2. The property is owned or controlled by a religious organization
  3. None of these is true:
    • The property is owned or controlled by a religious organization
  4. Not all of these are true:
    • The property is owned by a religious organization (as in RCW 36.01.290)
    • The affordable housing development is set aside for or occupied exclusively by low-income households (100 percent of units, households under 80 percent of Lewis County median income), new or rehabilitated
    • The development is under a lease or other binding obligation to be used exclusively for affordable housing for at least fifty years
    • The development does not discriminate against any qualifying low-income household or violate the federal Fair Housing Amendments Act of 1988
    • The property is located within an urban growth area as defined in RCW 36.70A.110
  5. All of these are true:
    • The property is owned by a religious organization (as in RCW 36.01.290)
    • The affordable housing development is set aside for or occupied exclusively by low-income households (100 percent of units, households under 80 percent of Lewis County median income), new or rehabilitated
    • The development is under a lease or other binding obligation to be used exclusively for affordable housing for at least fifty years
    • The development does not discriminate against any qualifying low-income household or violate the federal Fair Housing Amendments Act of 1988
    • The property is located within an urban growth area as defined in RCW 36.70A.110
  6. None of these is true:
    • The rear lot line abuts an alley, so the alley setback applies there
  7. The rear lot line abuts an alley, so the alley setback applies there
  8. Site is within 1/2 mile of transit
  9. None of these is true:
    • Site is within 1/2 mile of transit