Sign in

MRC - Mixed Residential/Commercial · MRC – Mixed Residential/Commercial

Chehalis, WA · CMC 17.55 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-family
Home✓1 H2 ADU✓3 ✓4
————
Manufactured home (single-family dwelling)
Home✓1 H2 ADU✓3 ✓4
————
Modular home (single-family dwelling)
Home✓1 H2 ADU✓3 ✓4
————
Condominium
Home✓5 ADU—
————
Permanent supportive housing
HomeH5 H6 ADU—
HomeH5 H6 ADU—
HomeH5 H6 ADU—
HomeH5 H6 ADU—
—
Transitional housing
HomeH5 H6 ADU—
HomeH5 H6 ADU—
HomeH5 H6 ADU—
HomeH5 H6 ADU—
—
Dwelling, duplex—
Home✓5 ADU—
———
Apartment house——
Home✓5 H6 ADU—
Home✓5 H6 ADU—
—
Dwelling, multiple unit——
Home✓5 H6 ADU—
Home✓5 H6 ADU—
—
Adult family home————
Home✓5 ADU—
Adult family residence————
Home✓5 ADU—
Children’s family home————
Home✓5 ADU—
Convalescent center————
Home✓5 H6 ADU—
Dwelling, special care————
Home✓5 ADU—
Group care facility————
HomeH5 H6 ADU—
Lodging house————
Home✓5 H6 ADU—
Rehabilitation center (halfway house)————
HomeH7 ADU—
Rehabilitation center (Oxford house)————
HomeH7 ADU—
Retirement center————
Home✓5 H6 ADU—
Retirement home————
Home✓5 ADU—
Indoor emergency housing/shelter————
Home✓8 ✓9 H10 H11 ADU—
Shelter, transient homeless————
Home✓8 ✓9 H10 H11 ADU—
Co-living housing————
Home✓5 ADU—
Children’s home (6 or more persons 6 to 18 years of age)————
HomeH12 ADU—
Nursing home (6 or more ambulatory persons)————
HomeH12 H6 ADU—
Nursing home (6 or more nonambulatory persons)————
HomeH12 H6 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set CMC 17.55.050; 17.55.100; 17.48.020
5,000 sq ft CMC 17.55.050; 17.55.100; 17.48.020
for Dwelling, single-family (1 unit)1; Manufactured home (single-family dwelling) (1 unit)1; Modular home (single-family dwelling) (1 unit)1; Condominium (1 unit)5; Dwelling, duplex (2 units)5; Apartment house (3, 4+ units)5; Dwelling, multiple unit (3, 4+ units)5; Adult family home (group living)5; Adult family residence (group living)5; Children’s family home (group living)5; Convalescent center (group living)5; Dwelling, special care (group living)5; Lodging house (group living)5; Retirement center (group living)5; Retirement home (group living)5; Indoor emergency housing/shelter (group living)8; Shelter, transient homeless (group living)8; Co-living housing (group living)5; Indoor emergency housing/shelter (group living)9; Shelter, transient homeless (group living)9
Minimum frontageNot set CMC 17.55.050; 17.55.100; 17.48.020
  • 16 ft13 CMC 17.55.050; 17.55.100; 17.48.020
  • 50 ft14 CMC 17.55.050; 17.55.100; 17.48.020
for Dwelling, single-family (1 unit)1; Manufactured home (single-family dwelling) (1 unit)1; Modular home (single-family dwelling) (1 unit)1; Condominium (1 unit)5; Dwelling, duplex (2 units)5; Apartment house (3, 4+ units)5; Dwelling, multiple unit (3, 4+ units)5; Adult family home (group living)5; Adult family residence (group living)5; Children’s family home (group living)5; Convalescent center (group living)5; Lodging house (group living)5; Retirement center (group living)5; Retirement home (group living)5; Indoor emergency housing/shelter (group living)8; Shelter, transient homeless (group living)8; Co-living housing (group living)5
50 ft CMC 17.55.050; 17.55.100; 17.63.020
for Indoor emergency housing/shelter (group living)9; Shelter, transient homeless (group living)9
Minimum densityDU Density Minimum/ Maximum: 6/18 units/acre. Note A: Minimum DU density is calculated on the zone; maximum DU density is calculated on the lot. CMC 17.55.050; 17.55.100; 17.48.020
0 units per acre CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
Maximum densityNot set CMC 17.55.050; 17.55.100; 17.48.020; 17.78.020 (R341)
  • 18 units per acre15 CMC 17.55.050; 17.55.100; 17.48.020
  • 18 × 1.1 units per acre16 CMC 17.55.050; 17.55.100; 17.48.020; 17.78.020 (note 20)(1)
for Dwelling, single-family (1 unit)1; Dwelling, single-family (1 unit)2; Manufactured home (single-family dwelling) (1 unit)1; Manufactured home (single-family dwelling) (1 unit)2; Modular home (single-family dwelling) (1 unit)1; Modular home (single-family dwelling) (1 unit)2; Condominium (1 unit)5; Permanent supportive housing (1, 2, 3, 4+ units)5; Transitional housing (1, 2, 3, 4+ units)5; Dwelling, duplex (2 units)5; Apartment house (3, 4+ units)5; Dwelling, multiple unit (3, 4+ units)5
  • 24 units per acre15 CMC 17.55.050; 17.55.100; 17.63.020
  • 24 × 1.1 units per acre16 CMC 17.55.050; 17.55.100; 17.63.020; 17.78.020 (note 20)(1)
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6
Maximum sleeping unitsNot set CMC 17.78.020 (R341)
4 × ((18 × lot area) ÷ 43,560), rounded down sleeping units CMC 17.55.050; 17.55.100; 17.48.020; 17.06.550; 17.78.020 (note 22)
for Co-living housing (group living)5

3. Building standards

StandardValueExceptions
Front setback20 ft CMC 17.55.050; 17.55.100; 17.48.020
10 ft CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
Side setback5 ft CMC 17.55.050; 17.55.100; 17.48.020
3 ft CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
Street side setback20 ft CMC 17.55.050; 17.55.100; 17.48.020
10 ft CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
Rear setback5 ft CMC 17.55.050; 17.55.100; 17.48.020
  • 3 ft17 CMC 17.55.050; 17.55.100; 17.63.020
  • 0 ft18 CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
  • 5 ft17 CMC 17.55.050; 17.55.100; 17.48.020
  • 0 ft19 CMC 17.55.050; 17.55.100; 17.48.020
  • 5 ft20 CMC 17.55.050; 17.55.100; 17.48.020
for Dwelling, special care (group living)5
Maximum height35 ft CMC 17.55.050; 17.55.100; 17.48.020
50 ft CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
Maximum lot coverage80% CMC 17.55.050; 17.55.100; 17.48.020
100% CMC 17.55.050; 17.55.100; 17.63.020
for Permanent supportive housing (1, 2, 3, 4+ units)6; Transitional housing (1, 2, 3, 4+ units)6; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6; Convalescent center (group living)6; Group care facility (group living)6; Lodging house (group living)6; Retirement center (group living)6; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6; Nursing home (6 or more nonambulatory persons) (group living)6
25% CMC 17.55.050; 17.55.100; 17.48.020
for Dwelling, special care (group living)5
Minimum parking1 space per unit CMC 17.78.020 (R149); 17.84.010(B)
2 spaces per unit CMC 17.78.020 (R311); 17.84.010(B); 17.84.020(F)
for Dwelling, single-family (1 unit)1; Dwelling, single-family (1 unit)2; Manufactured home (single-family dwelling) (1 unit)1; Manufactured home (single-family dwelling) (1 unit)2; Modular home (single-family dwelling) (1 unit)1; Modular home (single-family dwelling) (1 unit)2; Condominium (1 unit)5; Dwelling, duplex (2 units)5; Apartment house (3, 4+ units)5; Dwelling, multiple unit (3, 4+ units)5; Apartment house (3, 4+ units)6; Dwelling, multiple unit (3, 4+ units)6
2 + sleeping units in the project spaces CMC 17.78.020 (R341); 17.84.010(B)
for Adult family home (group living)5; Adult family residence (group living)5
residents ÷ 3 spaces CMC 17.78.020 (R142); 17.84.010(B)
for Children’s family home (group living)5
1 space per resident CMC 17.78.020 (R143); 17.84.010(B)
for Convalescent center (group living)5; Group care facility (group living)5; Rehabilitation center (halfway house) (group living)7; Rehabilitation center (Oxford house) (group living)7; Retirement home (group living)5; Convalescent center (group living)6; Group care facility (group living)6
1 space per sleeping unit CMC 17.78.020 (R331); 17.84.010(B)
for Lodging house (group living)5; Lodging house (group living)6
As required for the individual occupancies CMC 17.78.020 (R012); 17.78.020 (note 8)
for Retirement center (group living)5; Retirement center (group living)6
  • 0.25 spaces per bed21 CMC 17.78.020 (R147); 17.84.010(B)
  • beds in the project ÷ 3 spaces22 CMC 17.78.020 (R147); 17.84.010(B)
for Indoor emergency housing/shelter (group living)8; Indoor emergency housing/shelter (group living)10; Indoor emergency housing/shelter (group living)9; Indoor emergency housing/shelter (group living)11
beds in the project ÷ 3 spaces CMC 17.78.020 (R148); 17.84.010(B)
for Shelter, transient homeless (group living)8; Shelter, transient homeless (group living)10; Children’s home (6 or more persons 6 to 18 years of age) (group living)12; Nursing home (6 or more ambulatory persons) (group living)12; Shelter, transient homeless (group living)9; Shelter, transient homeless (group living)11; Nursing home (6 or more ambulatory persons) (group living)6
  • 0 spaces per sleeping unit23 CMC 17.78.020 (R152); 17.84.010(B)
  • 0.25 spaces per sleeping unit24 CMC 17.78.020 (R152); 17.84.010(B)
for Co-living housing (group living)5
1 space per bed CMC 17.78.020 (I114); 17.84.010(B)
for Nursing home (6 or more nonambulatory persons) (group living)12; Nursing home (6 or more nonambulatory persons) (group living)6

4. ADU standards

Lot

StandardValueExceptions
Minimum lot size5,000 sq ft CMC 17.55.050; 17.55.100; 17.48.020

Building

StandardValueExceptions
Front setback20 ft CMC 17.55.050; 17.55.100; 17.48.020
Side setback5 ft CMC 17.55.050; 17.55.100; 17.48.020
Rear setback
  • 5 ft17 CMC 17.55.050; 17.55.100; 17.48.020
  • 0 ft19 CMC 17.55.050; 17.55.100; 17.48.020
  • 5 ft20 CMC 17.55.050; 17.55.100; 17.48.020
Maximum height35 ft CMC 17.55.050; 17.55.100; 17.48.020
Minimum parking
  • 0 spaces per unit23 CMC 17.78.020 (R310); 17.84.020(G)(1)
  • 1 space per unit25 CMC 17.84.020(G)(2)
  • 2 spaces per unit26 CMC 17.78.020 (R310); 17.84.020(G)(3)
  • 0 spaces per unit23 CMC 17.78.020 (R312); 17.84.020(G)(1)
  • 1 space per unit24 CMC 17.78.020 (R312); 17.84.020(G)(2)-(3)
for Dwelling, single-family (1 unit)3; Dwelling, single-family (1 unit)4; Manufactured home (single-family dwelling) (1 unit)3; Manufactured home (single-family dwelling) (1 unit)4; Modular home (single-family dwelling) (1 unit)3; Modular home (single-family dwelling) (1 unit)4
Attached to the main houseNot required CMC 17.78.020 (R310)
Required CMC 17.78.020 (R312)
for Dwelling, single-family (1 unit)3; Dwelling, single-family (1 unit)4; Manufactured home (single-family dwelling) (1 unit)3; Manufactured home (single-family dwelling) (1 unit)4; Modular home (single-family dwelling) (1 unit)3; Modular home (single-family dwelling) (1 unit)4

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 17.09.030; 17.12A.200(A); 17.12A.200(E)(1) A 2 to 4 CMC 17.12A.010(B)(1); CMC 17.09.030 —
Minimum lot size
5,000 sq ft CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)(2)
Minimum lot width
Not set CMC 17.55.050; 17.55.100; 17.48.020; 17.06.450
Minimum lot depth
Not set CMC 17.55.050; 17.55.100; 17.48.020
Minimum frontage
  • 16 ft13 CMC 17.55.050; 17.55.100; 17.48.020
  • 50 ft14 CMC 17.55.050; 17.55.100; 17.48.020
Maximum units per lot
Not set CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)
Short subdivision CMC 17.09.030; 17.12A.200(A); 17.12A.200(E)(1)(d) H 5 to 9 CMC 17.09.030; CMC 17.12A.200(A); 17.12A.010(F) —
Minimum lot size
5,000 sq ft CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)(2)
Minimum lot width
Not set CMC 17.55.050; 17.55.100; 17.48.020; 17.06.450
Minimum lot depth
Not set CMC 17.55.050; 17.55.100; 17.48.020
Minimum frontage
  • 16 ft13 CMC 17.55.050; 17.55.100; 17.48.020
  • 50 ft14 CMC 17.55.050; 17.55.100; 17.48.020
Maximum units per lot
Not set CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)
Subdivision CMC 17.09.030; 17.12A.100(D) H 10 or more CMC 17.12A.010(F)
Minimum average lot size
5,000 sq ft CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)(1)(a)
Minimum lot size
5,000 sq ft CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)(1)
Minimum lot width
Not set CMC 17.55.050; 17.55.100; 17.48.020; 17.06.450
Minimum lot depth
Not set CMC 17.55.050; 17.55.100; 17.48.020
Minimum frontage
  • 16 ft13 CMC 17.55.050; 17.55.100; 17.48.020
  • 50 ft14 CMC 17.55.050; 17.55.100; 17.48.020
Maximum units per lot
Not set CMC 17.55.050; 17.55.100; 17.48.020; 17.12A.010(I)
Binding site plan CMC 17.09.030; 17.09.195(A); 17.12A.300(A) H
Maximum lots
Not set CMC 17.12A.300; 17.09.195
—
Minimum lot size
No limit CMC 17.12A.300(B)
Minimum lot width
No limit CMC 17.12A.300(B)
Minimum lot depth
No limit CMC 17.12A.300(B)
Minimum frontage
No limit CMC 17.12A.300(B)
Maximum units per lot
Not set CMC 17.12A.300(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • Lot area is less than 87,120 ÷ 18
  2. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • Lot area is at least 87,120 ÷ 18
  3. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • Lot area is less than 87,120 ÷ 18
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    None of these is true:
    • Lot is in a historic (HIS) district
  4. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • Lot area is at least 87,120 ÷ 18
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    None of these is true:
    • Lot is in a historic (HIS) district
  5. Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
  6. Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is cg
  7. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • Any of these is true:
      • Lot is adjacent to an arterial street (a street named in CMC 17.06.210)
      • The use is associated with an approved use
    • Site is more than 1,000 feet from any school, park, playground, day care and other like facility
  8. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • The property is owned or controlled by a religious organization
  9. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is cg
    • The property is owned or controlled by a religious organization
  10. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    None of these is true:
    • The property is owned or controlled by a religious organization
  11. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is cg
    None of these is true:
    • The property is owned or controlled by a religious organization
  12. All of these are true:
    • Which zone's uses and standards the applicant chooses for the MRC project: R-3 or C-G is r3
    • Any of these is true:
      • Lot is adjacent to an arterial street (a street named in CMC 17.06.210)
      • The use is associated with an approved use
  13. Flag lot: a lot with its principal developable area located rearward from a regular lot
  14. None of these is true:
    • Flag lot: a lot with its principal developable area located rearward from a regular lot
  15. Not all of these are true:
    • The property is owned by a religious organization (as in RCW 36.01.290)
    • The affordable housing development is set aside for or occupied exclusively by low-income households (100 percent of units, households under 80 percent of Lewis County median income), new or rehabilitated
    • The development is under a lease or other binding obligation to be used exclusively for affordable housing for at least fifty years
    • The development does not discriminate against any qualifying low-income household or violate the federal Fair Housing Amendments Act of 1988
    • The property is located within an urban growth area as defined in RCW 36.70A.110
  16. All of these are true:
    • The property is owned by a religious organization (as in RCW 36.01.290)
    • The affordable housing development is set aside for or occupied exclusively by low-income households (100 percent of units, households under 80 percent of Lewis County median income), new or rehabilitated
    • The development is under a lease or other binding obligation to be used exclusively for affordable housing for at least fifty years
    • The development does not discriminate against any qualifying low-income household or violate the federal Fair Housing Amendments Act of 1988
    • The property is located within an urban growth area as defined in RCW 36.70A.110
  17. None of these is true:
    • The rear lot line abuts an alley, so the alley setback applies there
  18. The rear lot line abuts an alley, so the alley setback applies there
  19. All of these are true:
    • The rear lot line abuts an alley, so the alley setback applies there
    None of these is true:
    • The accessory building has vehicle access from the alley that is not parallel to the alley
  20. All of these are true:
    • The rear lot line abuts an alley, so the alley setback applies there
    • The accessory building has vehicle access from the alley that is not parallel to the alley
  21. Site is within 1/2 mile of transit
  22. None of these is true:
    • Site is within 1/2 mile of transit
  23. Lot is within one-half mile walking distance of a major transit stop
  24. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  25. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  26. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop