Sign in

R-3 · R-3 (Multi-family Residential)

Cheney, WA · CMC 21.24 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single Dwelling, Detached
Home✓ ADU✓1
————
Single Dwelling, Attached
Home✓ ADU—
————
Manufactured Home
Home✓2 ADU✓3
————
Duplexes—
Home✓ ADU—
———
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Multi-Dwelling Units——
Home✓ ADU—
Home✓ ADU—
—
Senior Housing———
Home✓ ADU—
—
Residential Care Homes————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size
  • 2,500 sq ft4 CMC 21.24.050(C) note 1
  • 3,500 sq ft5 CMC 21.24.050(C)
6,000 sq ft CMC 21.24.050(C)
for Duplexes (2 units)
5,000 sq ft CMC 21.24.050(C)
for Multi-Dwelling Units (3, 4+ units); Senior Housing (4+ units)
Minimum lot width
  • 25 ft4 CMC 21.24.050(C) note 1
  • 35 ft5 CMC 21.24.050(C)
50 ft CMC 21.24.050(C)
for Duplexes (2 units); Multi-Dwelling Units (3, 4+ units); Senior Housing (4+ units)
Maximum density21 units per acre, a fraction of 0.5 or more rounds up, on the net lot area CMC 21.24.040(A)(1)-(3); 21.24.020(A); 21.10.020
Not set CMC 21.24.040; 21.24.050(C)
for Residential Care Homes (group living)
Maximum residents6 persons CMC 21.24.030(B) note 1; 21.08.010

3. Building standards

StandardValueExceptions
Front setback
  • 12 ft4 CMC 21.24.050(C) note 1
  • 15 ft5 CMC 21.24.050(C) note 1
Side setback
  • 0 ft6 CMC 21.24.050(C) note 3; 21.24.050(L)(2)
  • 5 ft7 CMC 21.24.050(C)
Total side setbacks10 ft CMC 21.24.050(C) note 3
Street side setback10 ft CMC 21.24.050(C)
Rear setback
  • 15 ft8 CMC 21.24.050(C) note 2
  • 20 ft9 CMC 21.24.050(C)
Maximum height35 ft CMC 21.24.050(C) note 4
Maximum lot coverage45% CMC 21.24.050(C)
Minimum parking2 spaces per unit CMC 21.24.060; 21.40.020(1)
1 × bedrooms in one unit spaces per unit CMC 21.24.060; 21.40.020(1)
for Duplexes (2 units)
the largest of 1, bedrooms in one unit spaces per unit CMC 21.24.060; 21.40.020(1); 21.40.020(8)
for Multi-Dwelling Units (3, 4+ units)
0.5 × bedrooms in one unit spaces per unit CMC 21.24.060; 21.40.020(1)
for Senior Housing (4+ units)
1 space per resident CMC 21.24.060; 21.40.020(1)
for Residential Care Homes (group living)
Minimum open space(250 ÷ lot area) × 100% CMC 21.24.050(C)
((75 × main dwelling units on the lot) ÷ lot area) × 100% CMC 21.24.050(C)
for Multi-Dwelling Units (3, 4+ units); Senior Housing (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit CMC 21.67.030(a)
Minimum lot size5,000 sq ft CMC 21.67.030(b)

Building

StandardValueExceptions
Front setback
  • 12 ft4 CMC 21.24.050(C) note 1; 21.67.030(e)
  • 15 ft5 CMC 21.24.050(C) note 1; 21.67.030(e)
Side setback
  • 0 ft6 CMC 21.24.050(C) note 3; 21.24.050(L)(2); 21.67.030(e)
  • 5 ft7 CMC 21.24.050(C); 21.67.030(e)
Rear setback
  • 15 ft8 CMC 21.24.050(C) note 2; 21.67.030(e)
  • 20 ft9 CMC 21.24.050(C); 21.67.030(e)
Maximum height
  • 25 ft10 CMC 21.67.030(f)
  • 35 ft11 CMC 21.67.030(f); 21.24.050(C)
Minimum parking
  • 0 spaces per unit12 CMC 21.67.030(k)
  • 1 space per unit13 CMC 21.67.030(k)
Maximum unit size0.4 × floor area of the main house sq ft CMC 21.67.030(i)
Attached to the main houseNot required CMC 21.67.030(d)(1)-(5)
Owner lives on siteRequired CMC 21.67.030(s)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat CMC 22.26.110(a) A up to 4 CMC 22.08.005 21 units per acre, a fraction of 0.5 or more rounds up, on the net lot area CMC 21.24.040(A)(1)-(3); 21.24.020(A); 21.10.020
Minimum lot size
  • 2,500 sq ft4 CMC 21.24.050(C) note 1
  • 3,500 sq ft5 CMC 21.24.050(C)
Minimum lot width
  • 25 ft4 CMC 21.24.050(C) note 1
  • 35 ft5 CMC 21.24.050(C)
Minimum lot depth
  • 120 ft14 CMC 22.24.040(6)
  • Not set15 CMC 21.24.050(C)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040
Subdivision CMC 22.12.020(a); 22.04.090 H 5 or more CMC 22.08.005 21 units per acre, a fraction of 0.5 or more rounds up, on the net lot area CMC 21.24.040(A)(1)-(3); 21.24.020(A); 21.10.020
Minimum lot size
  • 2,500 sq ft4 CMC 21.24.050(C) note 1
  • 3,500 sq ft5 CMC 21.24.050(C)
Minimum lot width
  • 25 ft4 CMC 21.24.050(C) note 1
  • 35 ft5 CMC 21.24.050(C)
Minimum lot depth
  • 120 ft14 CMC 22.24.040(6)
  • Not set15 CMC 21.24.050(C)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040
Binding site plan CMC 22.27.030(a) A16 up to 3 CMC 22.27.030(a) 21 units per acre, a fraction of 0.5 or more rounds up, on the net lot area CMC 21.24.040(A)(1)-(3); 21.24.020(A); 21.10.020
Minimum lot size
  • 2,500 sq ft4 CMC 21.24.050(C) note 1
  • 3,500 sq ft5 CMC 21.24.050(C)
Minimum lot width
  • 25 ft4 CMC 21.24.050(C) note 1
  • 35 ft5 CMC 21.24.050(C)
Minimum lot depth
  • 120 ft14 CMC 22.24.040(6)
  • Not set15 CMC 21.24.050(C)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040
Binding site plan CMC 22.27.030(b) H16 5 or more CMC 22.27.030(b) 21 units per acre, a fraction of 0.5 or more rounds up, on the net lot area CMC 21.24.040(A)(1)-(3); 21.24.020(A); 21.10.020
Minimum lot size
  • 2,500 sq ft4 CMC 21.24.050(C) note 1
  • 3,500 sq ft5 CMC 21.24.050(C)
Minimum lot width
  • 25 ft4 CMC 21.24.050(C) note 1
  • 35 ft5 CMC 21.24.050(C)
Minimum lot depth
  • 120 ft14 CMC 22.24.040(6)
  • Not set15 CMC 21.24.050(C)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • A home occupation is operating in the dwelling or on the lot
  2. The manufactured home is new
  3. All of these are true:
    • The manufactured home is new
    None of these is true:
    • A home occupation is operating in the dwelling or on the lot
  4. Parking (driveway) for the lot is accessed off an alley
  5. None of these is true:
    • Parking (driveway) for the lot is accessed off an alley
  6. The house is part of a zero lot line development of at least four lots grouped together, with one side setback reduced to zero
  7. None of these is true:
    • The house is part of a zero lot line development of at least four lots grouped together, with one side setback reduced to zero
  8. The lot is a corner lot
  9. None of these is true:
    • The lot is a corner lot
  10. The ADU is a separate detached dwelling unit (not an internal conversion or an addition to the primary dwelling)
  11. None of these is true:
    • The ADU is a separate detached dwelling unit (not an internal conversion or an addition to the primary dwelling)
  12. On-street parking (spaces legally available, not time- or day-restricted) is available for the ADU
  13. None of these is true:
    • On-street parking (spaces legally available, not time- or day-restricted) is available for the ADU
  14. The residential lot fronts on a community arterial
  15. None of these is true:
    • The residential lot fronts on a community arterial
  16. The improvements will be included in one or more condominiums or owned by an association in which the unit owners have a membership interest