Sign in

NC · Neighborhood Commercial (NC) District

Clark County, WA · CCC 40.230 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Residential (integrated multifamily/commercial or mixed use structure)
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓2 ADU—
—
One (1) single-family residence for an accessory caretaker, security or manager, or owner residence
Home✓3 ADU✓4
————
Adult family homes————
Home✓5 ADU—
Assisted living facilities————
Home✓1 ADU—
Residential care homes————
HomeA6 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit CCC Table 40.230.010-2
Minimum lot widthNo limit CCC Table 40.230.010-2
Minimum lot depthNo limit CCC Table 40.230.010-2
Maximum residents6 persons CCC 40.100.070
Not set CCC 40.100.070; 40.230.010
for Assisted living facilities (group living)1
10 persons CCC 40.100.070
for Residential care homes (group living)6

3. Building standards

StandardValueExceptions
Front setback
  • 0 ft7 CCC Table 40.230.010-3; Table 40.320.010-1(note 1)
  • 5 ft8 CCC Table 40.230.010-3; Table 40.320.010-1(note 1)
  • 10 ft9 CCC Table 40.230.010-3; Table 40.320.010-1
Side setback
  • the smallest of 40, 10 + (the largest of 0, (building height − 20) ÷ 2) ft10 CCC Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 5 ft11 CCC Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 0 ft12 CCC Table 40.230.010-3; Table 40.320.010-1(note 2)
  • 10 ft13 CCC Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
Street side setback
  • 0 ft7 CCC Table 40.230.010-3; Table 40.320.010-1(note 1)
  • 5 ft8 CCC Table 40.230.010-3; Table 40.320.010-1(note 1)
  • 10 ft9 CCC Table 40.230.010-3; Table 40.320.010-1
Rear setback
  • the smallest of 40, 10 + (the largest of 0, (building height − 20) ÷ 2) ft10 CCC Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 5 ft11 CCC Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 0 ft12 CCC Table 40.230.010-3; Table 40.320.010-1(note 2)
  • 10 ft13 CCC Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
Maximum heightNo limit CCC Table 40.230.010-3
Minimum stories2 stories CCC Table 40.230.010-1(1)
Not set CCC 40.230.010(D)
for One (1) single-family residence for an accessory caretaker, security or manager, or owner residence (1 unit)3; Adult family homes (group living)5; Residential care homes (group living)6
Maximum lot coverageMaximum determined by compliance with screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, the Stormwater and Erosion Control Ordinance (Chapter 40.386), and all other applicable standards. CCC Table 40.230.010-3
Minimum parking2 spaces per unit CCC 40.230.010(D)(3); Table 40.340.010-4(A)(1)
1 space per unit CCC 40.230.010(D)(3); Table 40.340.010-4(A)(2)
for Residential (integrated multifamily/commercial or mixed use structure) (2, 3 units)1
  • 1 space per unit14 CCC 40.230.010(D)(3); Table 40.340.010-4(A)(2)
  • 1.5 spaces per unit15 CCC 40.230.010(D)(3); Table 40.340.010-4(A)(5)
for Residential (integrated multifamily/commercial or mixed use structure) (4+ units)2
residents ÷ 3 spaces CCC 40.230.010(D)(3); 40.260.190(C)(2)
for Adult family homes (group living)5
main dwelling units on the lot ÷ 3 spaces CCC 40.230.010(D)(3); 40.260.190(D)(1); Table 40.340.010-4(A)(8)
for Assisted living facilities (group living)1
Minimum open space15% CCC 40.230.010(D)(4)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit CCC 40.260.210(B)(1)(a)

Building

StandardValueExceptions
Front setback
  • 0 ft7 CCC 40.260.210(B)(1); Table 40.230.010-3; Table 40.320.010-1(note 1)
  • 5 ft8 CCC 40.260.210(B)(1); Table 40.230.010-3; Table 40.320.010-1(note 1)
  • 10 ft9 CCC 40.260.210(B)(1); Table 40.230.010-3; Table 40.320.010-1
Side setback
  • the smallest of 40, 10 + (the largest of 0, (building height − 20) ÷ 2) ft10 CCC 40.260.210(B)(1); Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 5 ft11 CCC 40.260.210(B)(1); Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 0 ft12 CCC 40.260.210(B)(1); Table 40.230.010-3; Table 40.320.010-1(note 2)
  • 10 ft13 CCC 40.260.210(B)(1); Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
Rear setback
  • the smallest of 40, 10 + (the largest of 0, (building height − 20) ÷ 2) ft10 CCC 40.260.210(B)(1); Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 5 ft11 CCC 40.260.210(B)(1); Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
  • 0 ft12 CCC 40.260.210(B)(1); Table 40.230.010-3; Table 40.320.010-1(note 2)
  • 10 ft13 CCC 40.260.210(B)(1); Table 40.230.010-3; 40.230.010(D)(1); Table 40.320.010-1
Maximum heightNo limit CCC 40.260.210(B)(1); Table 40.230.010-3
Attached to the main houseNot required CCC 40.260.210(B)(1)(c)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat CCC 40.540.030 A up to 9 CCC 40.100.070; 40.540.030 —
Minimum lot size
No limit CCC Table 40.230.010-2
Minimum lot width
No limit CCC Table 40.230.010-2
Minimum lot depth
No limit CCC Table 40.230.010-2
Subdivision CCC 40.540.040(B)(2) H 10 or more CCC 40.100.070; 40.540.040 —
Minimum lot size
No limit CCC Table 40.230.010-2
Minimum lot width
No limit CCC Table 40.230.010-2
Minimum lot depth
No limit CCC Table 40.230.010-2
Exempt division (20 acres or 1/32 section) CCC 40.540.020(B)(4)(b) ✓ — —
Minimum lot size
871,200 sq ft CCC 40.540.020(B)(4)(b)
Binding site plan CCC 40.520.040(C)(1)(a); 40.520.040(B)(2)(c) A16
Maximum lots
Not set CCC 40.520.040(C)
—
Minimum lot size
No limit CCC Table 40.230.010-2

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residential use is built following or in conjunction with the commercial uses of the proposal (uses in Table 40.230.010-1 subsections (2), (3), (4), (7) through (15) and (18))
  2. Any of these is true:
    • The residential use is built following or in conjunction with the commercial uses of the proposal (uses in Table 40.230.010-1 subsections (2), (3), (4), (7) through (15) and (18))
    • All of these are true:
      • Lot is in the Vancouver Urban Growth Area
      • Before occupancy, a recorded restrictive covenant of at least 30 years requires 100% of the units at an average of 60% of area median income or less
      • Main dwelling units on the lot is at least 5
  3. The caretaker, security, manager or owner residence is in conjunction with a use permitted outright or by conditional use on the site
  4. All of these are true:
    • The caretaker, security, manager or owner residence is in conjunction with a use permitted outright or by conditional use on the site
    • The temporary dwelling is for a person listed in Section 40.260.210(A): a caregiver or care receiver, a farm caretaker or hired hand, a low-income relative over 62, or (forest and agricultural districts only) a relative or a purchaser where the seller kept a life estate
    • Any of these is true:
      • Lot area is at least 43,560 sf
      • The parcel can comply with the residential density standards of the zone with the temporary dwelling added
  5. An existing single-family dwelling or duplex is on the lot and the adult family home uses it
  6. Not all of these are true:
    • The residential care facility or home houses justice offenders and/or residents subject to partial or full confinement
    • The property is within 300 feet (property line to property line) of an existing school or licensed commercial day care center
  7. All of these are true:
    • Zoning of the land across the street (a public right-of-way) from the front or street-side lot line (row of Table 40.320.010-1) is one of multifamily, office_employment_university, commercial_mixed_use
    • The commercial building implements the Storefront Design Standards in Section 3.3 of Appendix F
  8. All of these are true:
    • Zoning of the land across the street (a public right-of-way) from the front or street-side lot line (row of Table 40.320.010-1) is one of multifamily, office_employment_university, commercial_mixed_use
    None of these is true:
    • The commercial building implements the Storefront Design Standards in Section 3.3 of Appendix F
  9. Zoning of the land across the street (a public right-of-way) from the front or street-side lot line (row of Table 40.320.010-1) is one of single_family, industrial_il_a, industrial_ih_ir, resource
  10. Zoning of the land that abuts the side or rear lot line and is not separated from the site by a street (row of Table 40.320.010-1) is one of single_family, multifamily
  11. Zoning of the land that abuts the side or rear lot line and is not separated from the site by a street (row of Table 40.320.010-1) is one of office_employment_university, industrial_il_a, resource
  12. Zoning of the land that abuts the side or rear lot line and is not separated from the site by a street (row of Table 40.320.010-1) is commercial_mixed_use
  13. Zoning of the land that abuts the side or rear lot line and is not separated from the site by a street (row of Table 40.320.010-1) is industrial_ih_ir
  14. Main dwelling units on the lot is at most 4
  15. Main dwelling units on the lot is at least 5
  16. The land is divided for sale or for lease of commercially or industrially zoned property (RCW 58.17.040(4))