Sign in

RC-1 · Rural center residential district RC-1

Clark County, WA · CCC 40.210 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached dwellings
Home✓ ADU✓1 ✓2
————
Adult family homes————
Home✓ ADU✓1 ✓2
Residential care homes————
HomeA ADU—
Staffed residential homes————
HomeA3 ADU—
Residential care facilities————
HomeA4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size
  • 43,560 sq ft5 CCC Table 40.210.030-2
  • A legal lot of record, as defined in Section 40.100.070 and created as a building site, which does not conform to minimum lot area, width or depth requirements of the zoning district in which it is currently situated may be developed, subject to the following:6 CCC 40.530.010(D)
Minimum lot width
  • 100 ft5 CCC Table 40.210.030-2(note 2)
  • A legal lot of record, as defined in Section 40.100.070 and created as a building site, which does not conform to minimum lot area, width or depth requirements of the zoning district in which it is currently situated may be developed, subject to the following:6 CCC 40.530.010(D)
Minimum lot depth
  • 140 ft5 CCC Table 40.210.030-2
  • A legal lot of record, as defined in Section 40.100.070 and created as a building site, which does not conform to minimum lot area, width or depth requirements of the zoning district in which it is currently situated may be developed, subject to the following:6 CCC 40.530.010(D)
Maximum residents6 persons CCC 40.100.070
10 persons CCC 40.100.070
for Residential care homes (group living)
Not set CCC 40.210.030(D)
for Residential care facilities (group living)4

3. Building standards

StandardValueExceptions
Front setback
  • 25 ft7 CCC Table 40.210.030-3(note 5)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC Table 40.210.030-3(note 4)
Side setback
  • 150 ft9 CCC Table 40.210.030-3(note 1)
  • 50 ft10 CCC Table 40.210.030-3(note 1)
  • 10 ft11 CCC Table 40.210.030-3(note 1)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC Table 40.210.030-3(note 4)
Street side setback
  • 25 ft7 CCC Table 40.210.030-3(note 5)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC Table 40.210.030-3(note 4)
Rear setback
  • 150 ft9 CCC Table 40.210.030-3(note 2)
  • 50 ft10 CCC Table 40.210.030-3(note 2)
  • 10 ft11 CCC Table 40.210.030-3(note 2)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC Table 40.210.030-3(note 4)
Maximum height35 ft CCC Table 40.210.030-3(note 3)
Maximum lot coverageNo limit CCC Table 40.210.030-3
Minimum parking2 spaces per unit CCC Table 40.340.010-4(A)(1); 40.210.030(D)(4)
residents ÷ 3 spaces CCC 40.260.190(C)(2)
for Adult family homes (group living)
1 × employees on the largest shift spaces CCC 40.260.205(C)(3)
for Staffed residential homes (group living)3
  • 1 ÷ 7 spaces per resident12 CCC Table 40.340.010-4(A)(7)
  • 1 ÷ 5 spaces per resident13 CCC Table 40.340.010-4(A)(7)
  • 1 ÷ 4 spaces per resident14 CCC Table 40.340.010-4(A)(7)
for Residential care facilities (group living)4

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit CCC 40.260.022(C)(1)

Building

StandardValueExceptions
Front setback
  • 25 ft7 CCC 40.260.022(C)(4); Table 40.210.030-3(note 5)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC 40.260.022(C)(4); Table 40.210.030-3(note 4)
Side setback
  • 150 ft9 CCC 40.260.022(C)(4); Table 40.210.030-3(note 1)
  • 50 ft10 CCC 40.260.022(C)(4); Table 40.210.030-3(note 1)
  • 10 ft11 CCC 40.260.022(C)(4); Table 40.210.030-3(note 1)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC 40.260.022(C)(4); Table 40.210.030-3(note 4)
Rear setback
  • 150 ft9 CCC 40.260.022(C)(4); Table 40.210.030-3(note 2)
  • 50 ft10 CCC 40.260.022(C)(4); Table 40.210.030-3(note 2)
  • 10 ft11 CCC 40.260.022(C)(4); Table 40.210.030-3(note 2)
  • Setbacks for nonconforming lots shall be those as set forth for conforming lots except in cases where the standard setbacks will result in the buildable area of the lot being reduced to less than ten thousand (10,000) square feet. In these cases setbacks may be reduced to achieve a building envelope of at least ten thousand (10,000) square feet; however, in no case may they be reduced to less than twenty (20) feet for the front setback and five (5) feet for the side and rear setbacks.8 CCC 40.260.022(C)(4); Table 40.210.030-3(note 4)
Maximum height35 ft CCC 40.260.022(C)(5); Table 40.210.030-3(note 3)
Minimum parking1 space per unit CCC 40.260.022(C)(7)
Not set CCC 40.260.210
for Single-family detached dwellings (1 unit)2; Adult family homes (group living)2
Maximum unit size1,500 sq ft CCC 40.260.022(C)(6)(a)
Not set CCC 40.260.210
for Single-family detached dwellings (1 unit)2; Adult family homes (group living)2
Attached to the main houseRequired CCC 40.260.022(A); 40.260.022(C)(3)
Not required CCC 40.260.210(B)(1)(c)
for Single-family detached dwellings (1 unit)2; Adult family homes (group living)2

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat CCC 40.540.030(C)(2) A up to 4 CCC 40.540.030(A); 40.100.070 —
Minimum lot size
43,560 sq ft CCC Table 40.210.030-2
Minimum lot width
100 ft CCC Table 40.210.030-2(note 2)
Minimum lot depth
140 ft CCC Table 40.210.030-2
Subdivision CCC 40.540.040(B)(2) H 5 or more CCC 40.100.070 —
Minimum lot size
43,560 sq ft CCC Table 40.210.030-2
Minimum lot width
100 ft CCC Table 40.210.030-2(note 2)
Minimum lot depth
140 ft CCC Table 40.210.030-2
Exempt division (20 acres or 1/32 section) CCC 40.540.020(B)(4)(b) ✓ — —
Minimum lot size
871,200 sq ft CCC 40.540.020(B)(4)(b)
Minimum lot width
100 ft CCC Table 40.210.030-2(note 2)
Minimum lot depth
140 ft CCC Table 40.210.030-2

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • A Type II home business operates in the dwelling or on the lot
  2. All of these are true:
    • The temporary dwelling is for a person listed in Section 40.260.210(A): a caregiver or care receiver, a farm caretaker or hired hand, a low-income relative over 62, or (forest and agricultural districts only) a relative or a purchaser where the seller kept a life estate
    • Any of these is true:
      • Lot area is at least 43,560 sf
      • The parcel can comply with the residential density standards of the zone with the temporary dwelling added
  3. None of these is true:
    • Another staffed residential home is within a one-mile radius of the site
  4. Lot area is at least 108,900 sf
  5. None of these is true:
    • The lot is a legal lot of record that is smaller or narrower than the zone minimum for new lots (legal nonconforming lot)
  6. The lot is a legal lot of record that is smaller or narrower than the zone minimum for new lots (legal nonconforming lot)
  7. None of these is true:
    • The lot is a nonconforming lot where the standard setbacks would leave a buildable area under 10,000 sq ft
  8. The lot is a nonconforming lot where the standard setbacks would leave a buildable area under 10,000 sq ft
  9. All of these are true:
    • The lot line abuts property zoned for surface mining uses
    None of these is true:
    • The lot is a nonconforming lot where the standard setbacks would leave a buildable area under 10,000 sq ft
  10. All of these are true:
    • The lot line abuts property zoned for agriculture, forestry or other natural resource use (a resource district)
    None of these is true:
    • The lot is a nonconforming lot where the standard setbacks would leave a buildable area under 10,000 sq ft
    • The lot line abuts property zoned for surface mining uses
  11. None of these is true:
    • The lot is a nonconforming lot where the standard setbacks would leave a buildable area under 10,000 sq ft
    • The lot line abuts property zoned for surface mining uses
    • The lot line abuts property zoned for agriculture, forestry or other natural resource use (a resource district)
  12. Age group of the residents served by the residential care facility is under_12
  13. Age group of the residents served by the residential care facility is age_12_to_17
  14. Age group of the residents served by the residential care facility is age_18_plus