Sign in

R · Residential

Concrete, WA · CMC 19.09.010 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwellings
Home✓ ADU✓1
————
Duplex—
Home✓ ADU—
———
Triplex——
Home✓ ADU—
——
Townhouse——
HomeH ADU—
HomeH ADU—
—
Fourplex———
Home✓ ADU—
—
Fiveplex———
HomeH ADU—
—
Sixplex———
HomeH ADU—
—
Stacked flats———
HomeH ADU—
—
Courtyard buildings———
HomeH ADU—
—
Cottage houses———
HomeH ADU—
—
Mixed-use———
HomeH ADU—
—
Affordable housing———
Home✓ ADU—
—
Permanent supportive housing (PSH)———
Home✓ ADU—
—
Co-living housing units————
HomeH ADU—
Transitional housing————
HomeH ADU—
Emergency housing————
HomeH ADU—
Emergency shelters————
HomeH ADU—
Encampments on a religious property————
HomeH ADU—
Group homes————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set CMC 19.20.020
4 units CMC 19.06.261
for Fourplex (4+ units); Courtyard buildings (4+ units)
5 units CMC 19.06.251
for Fiveplex (4+ units)
6 units CMC 19.06.691
for Sixplex (4+ units)
Minimum unitsNot set CMC 19.20.020
4 units CMC 19.06.261
for Fourplex (4+ units)
5 units CMC 19.06.251
for Fiveplex (4+ units)
6 units CMC 19.06.691
for Sixplex (4+ units)
Minimum lot size
  • 10,000 sq ft1 CMC 19.20.020
  • 12,500 sq ft2 CMC 19.20.020(1)
  • 6,000 sq ft1 CMC 19.20.020
  • 12,500 sq ft2 CMC 19.20.020(1)
for Single-family dwellings (1 unit)
  • 4,000 sq ft1 CMC 19.20.020
  • 12,500 sq ft2 CMC 19.20.020(1)
for Duplex (2 units)
  • 4,500 sq ft1 CMC 19.20.020
  • 12,500 sq ft2 CMC 19.20.020(1)
for Triplex (3 units); Fourplex (4+ units)
Minimum lot widthNot set CMC 19.20.020
50 ft CMC 19.20.020
for Single-family dwellings (1 unit)
45 ft CMC 19.20.020
for Duplex (2 units); Triplex (3 units); Fourplex (4+ units)
105 ft CMC 19.20.020
for Cottage houses (4+ units)
Minimum lot depthNot set CMC 19.20.020
80 ft CMC 19.20.020
for Single-family dwellings (1 unit)
85 ft CMC 19.20.020
for Duplex (2 units); Triplex (3 units); Fourplex (4+ units)
120 ft CMC 19.20.020
for Cottage houses (4+ units)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft3 CMC 19.20.020(3)
  • the depth of front yard required on each lot therein shall be not less than average depth of the front yards4 CMC 19.25.150(2)
  • 15 ft3 CMC 19.20.020(3)
  • the depth of front yard required on each lot therein shall be not less than average depth of the front yards4 CMC 19.25.150(2)
for Single-family dwellings (1 unit); Duplex (2 units)
Side setback5 ft CMC 19.20.020
Total side setbacks10 ft CMC 19.20.020(4)
Rear setback
  • 20 ft5 CMC 19.20.020
  • 0 ft6 CMC 19.20.020(5)
Maximum height35 ft CMC 19.20.020
Maximum lot coverage40% CMC 19.20.020
Minimum parking
  • 1 space per unit7 CMC 19.54.020
  • 2 spaces per unit8 CMC 19.54.020
1 + sleeping units in the project + (employees on the largest shift ÷ 4) spaces CMC 19.54.020
for Co-living housing units (group living)
sleeping units in the project + (employees on the largest shift ÷ 4) spaces CMC 19.54.020
for Transitional housing (group living); Emergency housing (group living); Emergency shelters (group living)
(0.25 × sleeping units in the project) + (employees on the largest shift ÷ 4) spaces CMC 19.54.020
for Encampments on a religious property (group living)
0.5 spaces per bed CMC 19.54.020
for Group homes (group living)
Maximum unit sizeNot set CMC 19.20.020
1,600 sq ft CMC 19.25.072(1)
for Cottage houses (4+ units)
Minimum open spaceNot set CMC 19.20.020
20% CMC 19.25.072(2); 19.06.131
for Cottage houses (4+ units)
Maximum units per buildingNot set CMC 19.20.020
4 units CMC 19.06.141
for Courtyard buildings (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units CMC 19.15.020(41); 19.25.090(16)
Minimum lot size6,000 sq ft CMC 19.20.020; 19.15.020(41)(b); 19.25.090(15)

Building

StandardValueExceptions
Front setback
  • 15 ft9 CMC 19.20.020(3)
  • the depth of front yard required on each lot therein shall be not less than average depth of the front yards10 CMC 19.25.150(2)
  • Existing structures, including but not limited to detached garages, may be converted into ADUs even if they violate current code requirements for setbacks or lot coverage11 CMC 19.25.090(10)
Side setback
  • 5 ft12 CMC 19.25.090(4); 19.20.020
  • Existing structures, including but not limited to detached garages, may be converted into ADUs even if they violate current code requirements for setbacks or lot coverage11 CMC 19.25.090(10)
Rear setback
  • 20 ft13 CMC 19.25.090(4); 19.20.020
  • 5 ft14 CMC 19.20.020(7)
  • 0 ft15 CMC 19.20.020(5); 19.25.090(14)
  • Existing structures, including but not limited to detached garages, may be converted into ADUs even if they violate current code requirements for setbacks or lot coverage11 CMC 19.25.090(10)
Maximum height
  • 35 ft16 CMC 19.25.090(20)
  • 28 ft17 CMC 19.25.090(20)
Minimum parking
  • 1 space per unit18 CMC 19.25.090(4)(a)
  • 0 spaces per unit19 CMC 19.25.090(4)(a)
Maximum unit size1,000 sq ft CMC 19.25.090(3)
Attached to the main houseNot required CMC 19.25.090(1); 19.25.090(16)
Owner lives on siteNot required CMC 19.25.090(17)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 18.08.030(5); 17.12.050(2) H up to 4 CMC 17.04.045; 17.12.010(1) —
Minimum lot size
  • 6,000 sq ft1 CMC 19.20.020
  • 12,500 sq ft2 CMC 19.20.020(1)
Minimum lot width
45 ft CMC 19.20.020
Minimum lot depth
80 ft CMC 19.20.020
Minimum frontage
Not set CMC 19.20.020
Maximum units per lot
Not set CMC 19.20.020
Subdivision CMC 17.08.026 H 5 or more CMC 17.04.045 —
Minimum lot size
  • 6,000 sq ft1 CMC 19.20.020
  • 12,500 sq ft2 CMC 19.20.020(1)
Minimum lot width
45 ft CMC 19.20.020
Minimum lot depth
80 ft CMC 19.20.020
Minimum frontage
Not set CMC 19.20.020
Maximum units per lot
Not set CMC 19.20.020
Planned unit developments CMC 19.15.020; 19.58.020 H —
Minimum parent area
  • 130,680 sq ft20 CMC 19.58.040(1)(a)
  • Not set21 CMC 19.58.040(1)(b)
Minimum lot size
Lot area; provided, that no lot is reduced by more than 20 percent of the minimum lot size in the underlying zone CMC 19.58.040(4)(a)
Minimum lot width
deviations from the underlying zoning district dimensional standards are allowed: ... Lot width and depth CMC 19.58.040(4)(b)
Minimum lot depth
deviations from the underlying zoning district dimensional standards are allowed: ... Lot width and depth CMC 19.58.040(4)(b)
Minimum frontage
Not set CMC 19.20.020
Maximum units per lot
Not set CMC 19.20.020

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Public sewer is available to the lot
  2. None of these is true:
    • Public sewer is available to the lot
  3. None of these is true:
    • Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
  4. Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
  5. None of these is true:
    • The lot has access to an accessible and open alley at the rear
  6. The lot has access to an accessible and open alley at the rear
  7. Bedrooms in one unit is at most 2
  8. Bedrooms in one unit is at least 3
  9. None of these is true:
    • Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
    • The ADU is made by converting an existing structure, such as a detached garage
  10. All of these are true:
    • Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
    None of these is true:
    • The ADU is made by converting an existing structure, such as a detached garage
  11. The ADU is made by converting an existing structure, such as a detached garage
  12. None of these is true:
    • The ADU is made by converting an existing structure, such as a detached garage
  13. All of these are true:
    • Not all of these are true:
      • The ADU is in a detached structure
      • Building height is at most 16
    None of these is true:
    • The lot has access to an accessible and open alley at the rear
    • The ADU is made by converting an existing structure, such as a detached garage
  14. All of these are true:
    • The ADU is in a detached structure
    • Building height is at most 16
    None of these is true:
    • The lot has access to an accessible and open alley at the rear
    • The ADU is made by converting an existing structure, such as a detached garage
  15. All of these are true:
    • The lot has access to an accessible and open alley at the rear
    None of these is true:
    • The ADU is made by converting an existing structure, such as a detached garage
  16. None of these is true:
    • The ADU is in a detached structure
  17. The ADU is in a detached structure
  18. None of these is true:
    • Improved public street parking is available on at least one side of the lot
    • The lot is within one-half mile walking distance of a major transit route
  19. Any of these is true:
    • Improved public street parking is available on at least one side of the lot
    • The lot is within one-half mile walking distance of a major transit route
  20. None of these is true:
    • The review authority finds one of the conditions that allow a PUD site under three acres
  21. The review authority finds one of the conditions that allow a PUD site under three acres