R · Residential
Concrete, WA · CMC 19.09.010 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwellings | — | — | — | — | |
| Duplex | — | Home✓ ADU— | — | — | — |
| Triplex | — | — | Home✓ ADU— | — | — |
| Townhouse | — | — | HomeH ADU— | HomeH ADU— | — |
| Fourplex | — | — | — | Home✓ ADU— | — |
| Fiveplex | — | — | — | HomeH ADU— | — |
| Sixplex | — | — | — | HomeH ADU— | — |
| Stacked flats | — | — | — | HomeH ADU— | — |
| Courtyard buildings | — | — | — | HomeH ADU— | — |
| Cottage houses | — | — | — | HomeH ADU— | — |
| Mixed-use | — | — | — | HomeH ADU— | — |
| Affordable housing | — | — | — | Home✓ ADU— | — |
| Permanent supportive housing (PSH) | — | — | — | Home✓ ADU— | — |
| Co-living housing units | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | HomeH ADU— |
| Emergency housing | — | — | — | — | HomeH ADU— |
| Emergency shelters | — | — | — | — | HomeH ADU— |
| Encampments on a religious property | — | — | — | — | HomeH ADU— |
| Group homes | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set CMC 19.20.020 | 4 units CMC 19.06.261
for Fourplex (4+ units); Courtyard buildings (4+ units) 5 units CMC 19.06.251
for Fiveplex (4+ units) 6 units CMC 19.06.691
for Sixplex (4+ units) |
| Minimum units | Not set CMC 19.20.020 | 4 units CMC 19.06.261
for Fourplex (4+ units) 5 units CMC 19.06.251
for Fiveplex (4+ units) 6 units CMC 19.06.691
for Sixplex (4+ units) |
| Minimum lot size | ||
| Minimum lot width | Not set CMC 19.20.020 | 50 ft CMC 19.20.020
for Single-family dwellings (1 unit) 45 ft CMC 19.20.020
for Duplex (2 units); Triplex (3 units); Fourplex (4+ units) 105 ft CMC 19.20.020
for Cottage houses (4+ units) |
| Minimum lot depth | Not set CMC 19.20.020 | 80 ft CMC 19.20.020
for Single-family dwellings (1 unit) 85 ft CMC 19.20.020
for Duplex (2 units); Triplex (3 units); Fourplex (4+ units) 120 ft CMC 19.20.020
for Cottage houses (4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft CMC 19.20.020 | |
| Total side setbacks | 10 ft CMC 19.20.020(4) | |
| Rear setback | ||
| Maximum height | 35 ft CMC 19.20.020 | |
| Maximum lot coverage | 40% CMC 19.20.020 | |
| Minimum parking | 1 + sleeping units in the project + (employees on the largest shift ÷ 4) spaces CMC 19.54.020
for Co-living housing units (group living) sleeping units in the project + (employees on the largest shift ÷ 4) spaces CMC 19.54.020
for Transitional housing (group living); Emergency housing (group living); Emergency shelters (group living) (0.25 × sleeping units in the project) + (employees on the largest shift ÷ 4) spaces CMC 19.54.020
for Encampments on a religious property (group living) 0.5 spaces per bed CMC 19.54.020
for Group homes (group living) | |
| Maximum unit size | Not set CMC 19.20.020 | 1,600 sq ft CMC 19.25.072(1)
for Cottage houses (4+ units) |
| Minimum open space | Not set CMC 19.20.020 | 20% CMC 19.25.072(2); 19.06.131
for Cottage houses (4+ units) |
| Maximum units per building | Not set CMC 19.20.020 | 4 units CMC 19.06.141
for Courtyard buildings (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units CMC 19.15.020(41); 19.25.090(16) | |
| Minimum lot size | 6,000 sq ft CMC 19.20.020; 19.15.020(41)(b); 19.25.090(15) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft CMC 19.25.090(3) | |
| Attached to the main house | Not required CMC 19.25.090(1); 19.25.090(16) | |
| Owner lives on site | Not required CMC 19.25.090(17) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision CMC 18.08.030(5); 17.12.050(2) | H | up to 4 CMC 17.04.045; 17.12.010(1) | — | Minimum lot width 45 ft CMC 19.20.020 Minimum lot depth 80 ft CMC 19.20.020 Minimum frontage Not set CMC 19.20.020 Maximum units per lot Not set CMC 19.20.020 |
| Subdivision CMC 17.08.026 | H | 5 or more CMC 17.04.045 | — | Minimum lot width 45 ft CMC 19.20.020 Minimum lot depth 80 ft CMC 19.20.020 Minimum frontage Not set CMC 19.20.020 Maximum units per lot Not set CMC 19.20.020 |
| Planned unit developments CMC 19.15.020; 19.58.020 | H | — | Minimum lot size Lot area; provided, that no lot is reduced by more than 20 percent of the minimum lot size in the underlying zone CMC 19.58.040(4)(a) Minimum lot width deviations from the underlying zoning district dimensional standards are allowed: ... Lot width and depth CMC 19.58.040(4)(b) Minimum lot depth deviations from the underlying zoning district dimensional standards are allowed: ... Lot width and depth CMC 19.58.040(4)(b) Minimum frontage Not set CMC 19.20.020 Maximum units per lot Not set CMC 19.20.020 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Public sewer is available to the lot
- None of these is true:
- Public sewer is available to the lot
- None of these is true:
- Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
- Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
- None of these is true:
- The lot has access to an accessible and open alley at the rear
- The lot has access to an accessible and open alley at the rear
- Bedrooms in one unit is at most 2
- Bedrooms in one unit is at least 3
- None of these is true:
- Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
- The ADU is made by converting an existing structure, such as a detached garage
- All of these are true:
- Buildings occupy 50 percent or more of the frontage on the lot's side of the street in the block
- The ADU is made by converting an existing structure, such as a detached garage
- The ADU is made by converting an existing structure, such as a detached garage
- None of these is true:
- The ADU is made by converting an existing structure, such as a detached garage
- All of these are true:
- Not all of these are true:
- The ADU is in a detached structure
- Building height is at most 16
- The lot has access to an accessible and open alley at the rear
- The ADU is made by converting an existing structure, such as a detached garage
- Not all of these are true:
- All of these are true:
- The ADU is in a detached structure
- Building height is at most 16
- The lot has access to an accessible and open alley at the rear
- The ADU is made by converting an existing structure, such as a detached garage
- All of these are true:
- The lot has access to an accessible and open alley at the rear
- The ADU is made by converting an existing structure, such as a detached garage
- None of these is true:
- The ADU is in a detached structure
- The ADU is in a detached structure
- None of these is true:
- Improved public street parking is available on at least one side of the lot
- The lot is within one-half mile walking distance of a major transit route
- Any of these is true:
- Improved public street parking is available on at least one side of the lot
- The lot is within one-half mile walking distance of a major transit route
- None of these is true:
- The review authority finds one of the conditions that allow a PUD site under three acres
- The review authority finds one of the conditions that allow a PUD site under three acres