D-C · D-C Downtown Commercial Zone
Des Moines, WA · DMMC 18.115 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Mixed use | — | ||||
| Adult family homes | — | — | — | — | Home✓ ADU— |
| Co-living housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — | |
| Emergency housing | — | — | — | — | |
| Emergency shelter | — | — | — | — | |
| Nursing homes | — | — | — | — | Home✓ ADU— |
| Retirement housing | — | — | — | — | Home✓ ADU— |
| Community care facilities | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum residents | Not set DMMC 18.115 | for Emergency housing (group living)2 20 persons DMMC 18.182.050(2)(a)(ii)
for Emergency shelter (group living)2 |
| Maximum beds | Not set DMMC 18.115 | floor area of all units ÷ 40, rounded down beds DMMC 18.182.050(2)(a)(ii)
for Emergency shelter (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Maximum front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum floor area ratio | ||
| Minimum parking | (employees on the largest shift ÷ 2) + (beds in the project ÷ 4) spaces DMMC 18.210.090(15)(j) | 2 spaces per unit DMMC 18.210.090(15)(h)(i)
for Mixed use (1, 2, 3, 4+ units)1 for Adult family homes (group living) for Co-living housing (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Binding site plan DMMC 17.30.050(2) | A | up to 4 DMMC 17.30.050(2) | — | Minimum lot size Not set DMMC 18.115; 17.35.050(1) Minimum lot width Not set DMMC 18.115; 17.35.050(1); 17.35.050(5) Minimum frontage 20 ft DMMC 17.35.050(4) |
| Binding site plan DMMC 17.30.050(2); 17.10.130 | H | 5 or more DMMC 17.30.050(2) | — | Minimum lot size Not set DMMC 18.115; 17.35.050(1) Minimum lot width Not set DMMC 18.115; 17.35.050(1); 17.35.050(5) Minimum frontage 20 ft DMMC 17.35.050(4) |
| Short subdivision DMMC 17.05.140 | A | up to 9 DMMC 17.05.020 | — | Minimum lot size Not set DMMC 18.115; 17.35.050(1) Minimum lot width Not set DMMC 18.115; 17.35.050(1); 17.35.050(5) Minimum frontage 20 ft DMMC 17.35.050(4) |
| Subdivision DMMC 17.10.130 | H | 10 or more DMMC 17.10.020 | — | Minimum lot size Not set DMMC 18.115; 17.35.050(1) Minimum lot width Not set DMMC 18.115; 17.35.050(1); 17.35.050(5) Minimum frontage 20 ft DMMC 17.35.050(4) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The dwelling units are in a building that also contains enclosed commercial, business, or retail uses meeting the mixed use requirements
- All of these are true:
- The site is within one-quarter mile of a transit stop
- The site is at least one-half mile from another supportive housing facility
- Any of these is true:
- The site is at least 1,000 feet from an elementary, middle or high school and from any other supportive housing facility
- The facility is permitted as a family or youth shelter
- The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
- None of these is true:
- The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
- The emergency housing facility has no separate units
- None of these is true:
- The emergency housing facility has no separate units
- The lot line abuts residentially zoned property, or lies on a right-of-way or private street that residentially zoned property also lies on
- None of these is true:
- The lot line abuts residentially zoned property, or lies on a right-of-way or private street that residentially zoned property also lies on
- Which area of Figure 4 of DMMC 18.115.070 the property is in is area_2
- Which area of Figure 4 of DMMC 18.115.070 the property is in is area_1
- All of these are true:
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_1
- Not all of these are true:
- The project uses the Area 1 height bonus authorized by the City Manager under DMMC 18.115.060(2)(a)
- Lot area is at least 20,000 sf
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_2
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_3
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_4
- All of these are true:
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_1
- The project uses the Area 1 height bonus authorized by the City Manager under DMMC 18.115.060(2)(a)
- Lot area is at least 20,000 sf
- Any of these is true:
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_4
- All of these are true:
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_1
- None of these is true:
- The project uses the public benefit incentive system
- All of these are true:
- Which area of Figure 1 of DMMC 18.115.060 the property is in is area_1
- The project uses the public benefit incentive system
- Floor area of one unit is at most 1,200
- Floor area of one unit is more than 1,200
- The project site is within a mile radius of the Sea-Tac Airport
- All of these are true:
- The unit is within one-half mile walking distance of a major transit stop
- The project site is within a mile radius of the Sea-Tac Airport
- None of these is true:
- The project site is within a mile radius of the Sea-Tac Airport
- The unit is within one-half mile walking distance of a major transit stop