Sign in

RM-1800 · RM-1,800 Residential: Multifamily 1,800 Zone

Des Moines, WA · DMMC 18.70 · Official code

By right: 1 unit, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwellings
Home✓ ADU✓
————
Townhouses
Home✓1 ADU✓1
————
Planned unit development
HomeH ADU—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Mixed use
HomeH2 ADU—
HomeH2 ADU—
HomeH2 ADU—
HomeH2 ADU—
—
Multiple-family dwellings——
Home✓ ADU—
Home✓ ADU—
—
Adult family homes————
Home✓3 ADU—
Co-living housing————
Home✓4 ADU—
Permanent supportive housing————
HomeH5 ADU—
Transitional housing————
HomeH5 ADU—
Group home facilities————
Home✓6 H7 ADU—
Foster care home (24 hour)————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set DMMC 18.70
the approval thereof may involve modifications in the regulations, requirements, and standards of the zone in which the project is located DMMC 18.230.120
for Planned unit development (4+ units)
Minimum units3 units DMMC 18.01.050
the approval thereof may involve modifications in the regulations, requirements, and standards of the zone in which the project is located DMMC 18.230.120
for Planned unit development (4+ units)
Not set DMMC 18.70
for Mixed use (4+ units)2
Minimum lot size7,200 sq ft DMMC 18.70.050
Minimum lot width60 ft DMMC 18.70.070
Maximum density1 unit per 1,800 sq ft DMMC 18.70.060
Not set DMMC 18.70
for Adult family homes (group living)3; Co-living housing (group living)4; Permanent supportive housing (group living)5; Transitional housing (group living)5; Group home facilities (group living)7; Group home facilities (group living)6; Foster care home (24 hour) (group living)
Maximum residentsNot set DMMC 18.70
  • 6 persons8 DMMC 18.01.050
  • 4 persons9 DMMC 18.01.050
for Adult family homes (group living)3
Maximum sleeping unitsNot set DMMC 18.70
(4 × lot area) ÷ 1,800, rounded down sleeping units DMMC 18.70.060; 18.58.060(3)
for Co-living housing (group living)4

3. Building standards

StandardValueExceptions
Front setback20 ft DMMC 18.70.080
Side setback
  • 5 ft10 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
  • 10 ft11 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
  • 15 ft12 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
Total side setbacks
  • 15 ft10 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
  • 20 ft11 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
  • 30 ft12 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
Street side setback
  • 10 ft10 DMMC 18.70.130(2)(a); 18.70.130(2)(a)(ii); 18.70.130(2)(e)
  • 10 ft11 DMMC 18.70.130(2)(a); 18.70.130(2)(a)(ii); 18.70.130(2)(e)
  • 15 ft12 DMMC 18.70.130(2)(a); 18.70.130(2)(a)(ii); 18.70.130(2)(e)
Rear setback20 ft DMMC 18.70.100; 18.70.130(1)(a)
Building separation10 ft DMMC 18.70.130(1)(b)
Maximum height35 ft DMMC 18.70.110
Maximum lot coverage50% DMMC 18.70.120
Minimum parking
  • 0 spaces per unit13 DMMC 18.210.090(15)(a)(i)
  • 1 space per unit14 DMMC 18.210.090(15)(a)(ii)
2 spaces per unit DMMC 18.210.090(15)(h)(i)
for Mixed use (1, 2, 3, 4+ units)2
  • Parking requirements of the underlying zoning district apply, if the project site is located within a mile radius of the Sea-Tac Airport15 DMMC 18.58.070(4)
  • 0 spaces per sleeping unit16 DMMC 18.58.070(2)
  • 0.25 spaces per sleeping unit17 DMMC 18.58.070(1)
for Co-living housing (group living)4
(employees on the largest shift ÷ 2) + main dwelling units on the lot spaces DMMC 18.210.090(15)(k)
for Permanent supportive housing (group living)5; Transitional housing (group living)5
(employees on the largest shift ÷ 5) + (beds in the project ÷ 4) spaces DMMC 18.210.090(15)(g)
for Group home facilities (group living)7; Group home facilities (group living)6
Maximum units per buildingNot set DMMC 18.70
4 units DMMC 18.52.010A(15); 18.60.080(1)
for Townhouses (1 unit)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units3 units DMMC 18.52.010A(52); 18.55.140(1)(b)
Minimum lot size7,200 sq ft DMMC 18.70.050

Building

StandardValueExceptions
Front setback20 ft DMMC 18.70.080
Side setback
  • 5 ft10 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
  • 10 ft11 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
  • 15 ft12 DMMC 18.70.090; 18.70.130(1)(a); 18.70.090(1)-(2)
Rear setback20 ft DMMC 18.70.100; 18.70.130(1)(a)
Maximum height35 ft DMMC 18.70.110
Minimum parking0 spaces per unit DMMC 18.210.090(15)(i); 18.210.090(15)(a)(i)
Maximum unit size1,200 sq ft DMMC 18.52.010A(52); 18.55.140(1)(d)
Attached to the main houseNot required DMMC 18.55.140(1)(b)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision DMMC 17.05.140 A up to 9 DMMC 17.05.020
Minimum average lot size
7,200 sq ft DMMC 18.70.050
Minimum lot size
7,200 sq ft DMMC 18.70.050
Minimum lot width
  • 60 + 5 ft18 DMMC 18.70.070; 17.35.050(5)
  • 60 ft19 DMMC 18.70.070
Minimum frontage
20 ft DMMC 17.35.050(4)
Modified subdivisions and short subdivisions DMMC 17.15.060; 17.05.140 A up to 9 DMMC 17.05.020
Minimum average lot size
7,200 sq ft DMMC 18.70.050
Minimum lot size
7,200 sq ft DMMC 18.70.050
Minimum lot width
60 ft DMMC 18.70.070; 17.15.070(2)
Minimum frontage
an innovative or unusual subdivision or short subdivision that does not comply with one or more of the requirements specified in chapter 17.35 DMMC DMMC 17.15.050; 17.35.050(4)
Subdivision DMMC 17.10.130 H 10 or more DMMC 17.10.020
Minimum average lot size
7,200 sq ft DMMC 18.70.050
Minimum lot size
7,200 sq ft DMMC 18.70.050
Minimum lot width
  • 60 + 5 ft18 DMMC 18.70.070; 17.35.050(5)
  • 60 ft19 DMMC 18.70.070
Minimum frontage
20 ft DMMC 17.35.050(4)
Modified subdivisions and short subdivisions DMMC 17.15.060; 17.10.130 H 10 or more DMMC 17.10.020
Minimum average lot size
7,200 sq ft DMMC 18.70.050
Minimum lot size
7,200 sq ft DMMC 18.70.050
Minimum lot width
60 ft DMMC 18.70.070; 17.15.070(2)
Minimum frontage
an innovative or unusual subdivision or short subdivision that does not comply with one or more of the requirements specified in chapter 17.35 DMMC DMMC 17.15.050; 17.35.050(4)
Binding site plan DMMC 17.30.050(2) A20 up to 4 DMMC 17.30.050(2) —
Minimum lot size
7,200 sq ft DMMC 18.70.050
Minimum lot width
  • 60 + 5 ft18 DMMC 18.70.070; 17.35.050(5)
  • 60 ft19 DMMC 18.70.070
Minimum frontage
20 ft DMMC 17.35.050(4)
Binding site plan DMMC 17.30.050(2); 17.10.130 H20 5 or more DMMC 17.30.050(2) —
Minimum lot size
7,200 sq ft DMMC 18.70.050
Minimum lot width
  • 60 + 5 ft18 DMMC 18.70.070; 17.35.050(5)
  • 60 ft19 DMMC 18.70.070
Minimum frontage
20 ft DMMC 17.35.050(4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot area is at least 7,200 sf
  2. The dwelling units are in a building that also contains enclosed commercial, business, or retail uses meeting the mixed use requirements
  3. The adult family home is licensed as an adult family home by the Department of Social and Health Services
  4. Lot area is at least 10,800 sf
  5. All of these are true:
    • The site is within one-quarter mile of a transit stop
    • The site is at least one-half mile from another supportive housing facility
    • Any of these is true:
      • The site is at least 1,000 feet from an elementary, middle or high school and from any other supportive housing facility
      • The facility is permitted as a family or youth shelter
  6. The City and the proponent agree to process the application with a development agreement under chapter 18.255 DMMC
  7. None of these is true:
    • The City and the proponent agree to process the application with a development agreement under chapter 18.255 DMMC
  8. The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
  9. None of these is true:
    • The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
  10. Building stories is at most 1
  11. All of these are true:
    • Building stories is more than 1
    • Building stories is at most 2
  12. Building stories is more than 2
  13. Floor area of one unit is at most 1,200
  14. Floor area of one unit is more than 1,200
  15. The project site is within a mile radius of the Sea-Tac Airport
  16. All of these are true:
    • The unit is within one-half mile walking distance of a major transit stop
    None of these is true:
    • The project site is within a mile radius of the Sea-Tac Airport
  17. None of these is true:
    • The project site is within a mile radius of the Sea-Tac Airport
    • The unit is within one-half mile walking distance of a major transit stop
  18. The lot is a corner lot
  19. None of these is true:
    • The lot is a corner lot
  20. The improvements will be included in one or more condominiums or owned by an association