T-C · T-C Transit Community Zone
Des Moines, WA · DMMC 18.136 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Mixed use | — | ||||
| Adult family homes | — | — | — | — | Home✓ ADU— |
| Co-living housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — | |
| Emergency housing | — | — | — | — | |
| Emergency shelter | — | — | — | — | |
| Retirement housing | — | — | — | — | Home✓ ADU— |
| Community care facilities | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 7,500 sq ft DMMC 18.136.060(1) | |
| Minimum lot width | 75 ft DMMC 18.136.060(2) | |
| Minimum frontage | 20 ft DMMC 17.35.050(4) | |
| Maximum residents | Not set DMMC 18.136 | 80 persons DMMC 18.182.050(2)(a)(ii)
for Emergency shelter (group living)2 |
| Maximum beds | Not set DMMC 18.136 | floor area of all units ÷ 40, rounded down beds DMMC 18.182.050(2)(a)(ii)
for Emergency shelter (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft DMMC 18.136.060(3) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum height | 55 ft DMMC 18.136.060(7)(a)(i) | |
| Maximum floor area ratio |
|
|
| Minimum parking | for Adult family homes (group living) for Co-living housing (group living) (employees on the largest shift ÷ 2) + (0.5 × main dwelling units on the lot) spaces DMMC 18.210.090(15)(k)
|
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Binding site plan DMMC 17.30.050(2) | A | up to 4 DMMC 17.30.050(2) | — | Minimum lot size 7,500 sq ft DMMC 18.136.060(1) Minimum frontage 20 ft DMMC 17.35.050(4) |
| Binding site plan DMMC 17.30.050(2); 17.10.130 | H | 5 or more DMMC 17.30.050(2) | — | Minimum lot size 7,500 sq ft DMMC 18.136.060(1) Minimum frontage 20 ft DMMC 17.35.050(4) |
| Short subdivision DMMC 17.05.140 | A | up to 9 DMMC 17.05.020 | — | Minimum lot size 7,500 sq ft DMMC 18.136.060(1) Minimum frontage 20 ft DMMC 17.35.050(4) |
| Subdivision DMMC 17.10.130 | H | 10 or more DMMC 17.10.020 | — | Minimum lot size 7,500 sq ft DMMC 18.136.060(1) Minimum frontage 20 ft DMMC 17.35.050(4) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The dwelling units are in a building that also contains enclosed commercial, business, or retail uses meeting the mixed use requirements
- All of these are true:
- The site is within one-quarter mile of a transit stop
- The site is at least one-half mile from another supportive housing facility
- Any of these is true:
- The site is at least 1,000 feet from an elementary, middle or high school and from any other supportive housing facility
- The facility is permitted as a family or youth shelter
- The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
- None of these is true:
- The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
- The lot abuts Single-Family Residential zoned property
- None of these is true:
- The lot abuts Single-Family Residential zoned property
- All of these are true:
- The site or project area is planned for multiple buildings as one development or in phases
- Buildings are served by a private joint-use access or street that separates the rear yards of the development sites
- At least 30 feet of separation is provided between buildings
- The lot abuts Single-Family Residential zoned property
- All of these are true:
- Not all of these are true:
- The site or project area is planned for multiple buildings as one development or in phases
- Buildings are served by a private joint-use access or street that separates the rear yards of the development sites
- At least 30 feet of separation is provided between buildings
- The lot abuts Single-Family Residential zoned property
- Not all of these are true:
- All of these are true:
- The lot abuts I-C zoned property
- The lot abuts Single-Family Residential zoned property
- None of these is true:
- The lot abuts Single-Family Residential zoned property
- The lot abuts I-C zoned property
- The building part is within 40 feet of the abutting Single-Family Residential zone
- All of these are true:
- The lot abuts I-C zoned property
- The building part is within 40 feet of the abutting Single-Family Residential zone
- None of these is true:
- The building part is within 40 feet of the abutting Single-Family Residential zone
- The lot abuts I-C zoned property
- Building height is at most 35
- All of these are true:
- Building height is more than 35
- Building height is at most 50
- All of these are true:
- Building height is more than 50
- Building height is at most 60
- All of these are true:
- Building height is more than 60
- Building height is at most 70
- All of these are true:
- Building height is more than 70
- Building height is at most 80
- All of these are true:
- Building height is more than 80
- Building height is at most 90
- All of these are true:
- Building height is more than 90
- Building height is at most 100
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is at least 2
- Floor area of one unit is at most 1,200
- Floor area of one unit is more than 1,200
- The project site is within a mile radius of the Sea-Tac Airport
- All of these are true:
- The unit is within one-half mile walking distance of a major transit stop
- The project site is within a mile radius of the Sea-Tac Airport
- None of these is true:
- The project site is within a mile radius of the Sea-Tac Airport
- The unit is within one-half mile walking distance of a major transit stop
- The lot is a corner lot
- None of these is true:
- The lot is a corner lot