MT · Midtown (MT) zoning district
Duvall, WA · DMC 14.20 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling units on upper floors | — | ||||
| Adult family home | — | — | — | — | |
| Co-living housing | — | — | — | — | |
| Residential care facilities | — | — | — | — | |
| Nursing and personal care facilities | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 0 sq ft DMC 14.20.050(A) | |
| Minimum lot width | 25 ft DMC 14.20.050(A) | |
| Maximum density | Building and site plan limitations determine density for upper-floor residential DMC 14.20.050(A) | |
| Maximum residents | Not set DMC 14.20.050(A) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Side setback | 0 ft DMC 14.20.050(A) | |
| Rear setback | 0 ft DMC 14.20.050(A) | |
| Maximum height | 35 ft DMC 14.20.050(A) | |
| Maximum stories | Two floors allowed on the uphill side and three floors allowed on the downhill side. DMC 14.20.050(A) | |
| Maximum impervious surface | 75% DMC 14.20.050(A) | |
| Minimum parking | If this chapter does not specify a parking requirement for a land use, the director shall establish the minimum requirement based on either parking requirements for a similar use, parking requirements as established by state law, or a study of anticipated parking demand. DMC 14.44.020(B)
0.25 × bedrooms in the whole project spaces DMC 14.44.040(I)
floor area of all units ÷ 300 spaces DMC 14.44.040(I)
| |
| Maximum building floor area | 35,000 sq ft DMC 14.20.020 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Binding Site Plan DMC Table 14.08.040.A; 14.66.130(B) | H8 | — | — | Minimum lot width 25 ft DMC 14.20.050(A) |
| Plat—Short DMC Table 14.08.040.A; 14.66.030(A) | A | up to 4 DMC 14.06.160 | — | Minimum lot width 25 ft DMC 14.20.050(A) |
| Plat—Long DMC Table 14.08.040.A; 14.66.030(A) | H | 5 or more DMC 14.06.160 | — | Minimum lot width 25 ft DMC 14.20.050(A) |
| Boundary Line Adjustment DMC Table 14.08.040.A; 14.66.120 | ✓ | up to 0 DMC 14.06.020 | — | Minimum lot width 25 ft DMC 14.20.050(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The dwelling units are on upper floors
- The project gets a conditional use permit for a building larger than the zone's building size limit
- All of these are true:
- The dwelling units are on upper floors
- The project gets a conditional use permit for a building larger than the zone's building size limit
- None of these is true:
- The project gets a conditional use permit for a building larger than the zone's building size limit
- The project gets a conditional use permit for a building larger than the zone's building size limit
- Bedrooms in one unit is less than 1
- Bedrooms in one unit is 1
- Bedrooms in one unit is at least 2
- Any of these is true:
- The division is for lease or sale of lots or tracts for industrial or commercial purposes, with more than one principal building on one lot of record
- The land is divided to be developed for residential condominiums, single-family attached or detached, under Chapter 64.32 RCW