AP · Aerospace district
Eatonville, WA · EMC 18.04.185 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | — | — | — | — | |
| Sanitarium, convalescent and rest home services | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 21,500 sq ft EMC 18.04.185(E) | |
| Minimum lot width | 100 ft EMC 18.04.185(E) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft EMC 18.04.185(F) | |
| Side setback | 8 ft EMC 18.04.185(F) | |
| Street side setback | 25 ft EMC 18.04.185(F) | |
| Rear setback | 25 ft EMC 18.04.185(F) | |
| Maximum height | 28 ft EMC 18.04.185(D)(5) | 38 ft EMC 18.04.185(D)(5)
for Sanitarium, convalescent and rest home services (group living)3 |
| Minimum parking | 2 spaces per unit EMC 18.04.185(G); 18.05.040(A)(1)(a) | One parking space for each two beds, plus one parking space for each staff doctor, plus one parking space for each three employees. EMC 18.05.040(F)(2)
for Sanitarium, convalescent and rest home services (group living)3 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit EMC 18.08.045(B) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft EMC 18.08.045(C)(2); 18.04.185(F) | |
| Side setback | 8 ft EMC 18.08.045(C)(2); 18.04.185(F) | |
| Rear setback | 25 ft EMC 18.08.045(C)(2); 18.04.185(F) | |
| Maximum height | 28 ft EMC 18.08.045(B)(3); 18.04.185(D)(5) | |
| Maximum unit size | the largest of 500, the smallest of 0.4 × floor area of the main house, 1,000 sq ft EMC 18.08.045(B)(4); 18.08.045(B)(4)(a) | |
| Attached to the main house | Not required EMC 18.08.045(B) | |
| Owner lives on site | Required EMC 18.08.045(E)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat/subdivision EMC 17.44.040; 17.44.090(A) | A | up to 4 EMC 17.44.030(A) | — | Minimum lot size 21,500 sq ft EMC 18.04.185(E) Minimum lot width 100 ft EMC 18.04.185(E) |
| Subdivision EMC 17.20.060; 17.20.080(A) | H | 5 or more EMC 17.20.010 | — | Minimum lot size 21,500 sq ft EMC 18.04.185(E) Minimum lot width 100 ft EMC 18.04.185(E) |
| Lot size averaging EMC 17.18.050 | A | — | Minimum average lot size 21,500 sq ft EMC 17.18.050(A); 18.04.185(E) |
Minimum lot size 0.95 × 21,500 sq ft EMC 17.18.050(A)(2) |
| Binding site plan EMC 17.14.010 | A | Maximum lots Not set EMC 17.14.010 |
— | Minimum lot size 21,500 sq ft EMC 18.04.185(E) |
| Planned unit development EMC 17.17.010; 18.04.190(A); 18.04.190(E)(5) | H | — | The density of residential development for PUDs shall be based on the gross density of the underlying zoning district. The planning commission may recommend a dwelling unit density not more than 20 percent greater than that permitted by the underlying zone EMC 18.04.190(D) | Minimum lot size No limit EMC 18.04.190(C)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is in Runway Protection Zone 1 of the airport overlay (Map A)
- The lot is in Inner Safety Zone 2 of the airport overlay (Map A)
- The lot is in Inner Turning Zone 3 of the airport overlay (Map A)
- All of these are true:
- Any of these is true:
- The lot is in Inner Safety Zone 2 of the airport overlay (Map A)
- The lot is in Inner Turning Zone 3 of the airport overlay (Map A)
- The lot is in Runway Protection Zone 1 of the airport overlay (Map A)
- Any of these is true:
- None of these is true:
- The lot is in Runway Protection Zone 1 of the airport overlay (Map A)
- The lot is in Inner Safety Zone 2 of the airport overlay (Map A)