Sign in

MF-2 · Multifamily residential district, high density

Eatonville, WA · EMC 18.04.040 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU—
————
Duplex—
Home✓ ADU—
———
Multiple-family dwellings, including apartments and townhouses——
Home✓ ADU—
Home✓ ADU—
—
Cottage housing——
Home✓ ADU—
Home✓ ADU—
—
Mobile home parks———
HomeH ADU—
—
Permanent supportive housing———
Home✓1 ADU—
—
Group home, class I-A————
Home✓ ADU—
Group home, class I-B————
Home✓ ADU—
Group home, class I-C————
Home✓ ADU—
Group home, class II-A————
HomeH2 ADU—
Group home, class II-B————
HomeH2 ADU—
Group home, class II-C————
HomeH2 ADU—
Retirement homes, convalescent homes, and other welfare facilities————
HomeH ADU—
Transitional housing————
Home✓1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (4+ units)
Minimum unitsNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (4+ units)
6 units EMC 18.02.268
for Mobile home parks (4+ units)
Minimum lot size8,400 sq ft EMC 18.04.040(G)(1); 18.04.020(A); 18.04.020(G)(1)
8,500 + (1,600 × (the largest of main dwelling units on the lot − 2, 0)) sq ft EMC 18.04.040(G)(2)(a)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Minimum lot width60 ft EMC 18.04.040(G)(1); 18.04.020(G)(2)
70 ft EMC 18.04.040(G)(2)(b)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Minimum lot depthNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum frontageNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum densityNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum densityNot set EMC 18.04.040
23 units per acre EMC 18.04.040(G)(2)(c)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum development sizeNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum residents7 persons EMC 18.02.173(A)(1)
10 persons EMC 18.02.173(A)(2)
for Group home, class I-B (group living)
The number of residents for a class I-C group home will be based upon the density of the underlying zoning district. EMC 18.02.173(A)(3)
for Group home, class I-C (group living)
8 persons EMC 18.02.173(B)(1)
for Group home, class II-A (group living)2
12 persons EMC 18.02.173(B)(2)
for Group home, class II-B (group living)2
18 persons EMC 18.02.173(B)(3)
for Group home, class II-C (group living)2
Not set EMC 18.08.030(B)(4)
for Retirement homes, convalescent homes, and other welfare facilities (group living)
Each permanent supportive housing unit or transitional housing unit is limited to the occupant maximum as specified in the Town Building and Fire Codes. EMC 18.08.360(D)
for Transitional housing (group living)1

3. Building standards

StandardValueExceptions
Front setback25 ft EMC 18.04.040(G)(1); 18.04.020(G)(4)(a)
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Maximum front setbackNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Side setback8 ft EMC 18.04.040(G)(1); 18.04.020(G)(4)(b)
the smallest of 0.08 × lot width, 30 ft EMC 18.04.040(G)(2)(e)(ii)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Total side setbacksNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Street side setback15 ft EMC 18.04.040(G)(1); 18.04.020(G)(4)(d)
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Rear setback
  • 8 ft3 EMC 18.04.040(G)(1); 18.04.020(G)(4)(c)
  • Minimum rear yard is eight feet, provided that the minimum rear yard setback for property with a rear yard abutting on an alley shall be the greater of two feet, or 12 feet from the alley center line.4 EMC 18.04.040(G)(1); 18.04.020(G)(4)(c)
20 ft EMC 18.04.040(G)(2)(e)(iii)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Building separationNot set EMC 18.04.040
The distance between principal buildings shall be at least one-half the sum of the height of both buildings; provided, however, that in no case shall the distance be less than 12 feet. EMC 18.04.040(G)(2)(f)(ii)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum height28 ft EMC 18.04.040(G)(1); 18.04.020(G)(5)
40 ft EMC 18.04.040(G)(2)(h)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Maximum storiesNot set EMC 18.04.040
3 stories EMC 18.04.040(G)(2)(h)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum heightNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum storiesNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum lot coverage40% EMC 18.04.040(G)(1); 18.04.020(G)(3)
45% EMC 18.04.040(G)(2)(d)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units); Permanent supportive housing (4+ units)1
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Not set EMC 18.04.040
for Mobile home parks (4+ units)
Maximum impervious surfaceNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum floor area ratioNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum parkingFor uses not specifically identified in this section, the amount of parking required shall be determined by the planning director, based on parking required for similar uses, and, if appropriate, documentation provided by the applicant. EMC 18.05.040(H)
2 spaces per unit EMC 18.04.040(I)(1); 18.05.040(A)(1)(a)
for Single-family dwelling (1 unit); Duplex (2 units); Mobile home parks (4+ units)
  • 1 space per unit5 EMC 18.04.040(I)(1); 18.05.040(A)(1)(c)
  • 2 spaces per unit6 EMC 18.04.040(I)(1); 18.05.040(A)(1)(c)
  • 1.8 spaces per unit7 EMC 18.04.040(I)(1); 18.05.040(A)(1)(c)
for Multiple-family dwellings, including apartments and townhouses (3, 4+ units)
Not read EMC 19.06
for Cottage housing (3, 4+ units)
One parking space for each two beds, plus one parking space for each staff doctor, plus one parking space for each three employees. EMC 18.05.040(F)(2)
for Retirement homes, convalescent homes, and other welfare facilities (group living)
Maximum unit sizeNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum building floor areaNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum lot sizeNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum building footprintNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Minimum open spaceNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)
Maximum units per buildingNot set EMC 18.04.040
Not read EMC 19.06
for Cottage housing (3, 4+ units)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat/subdivision EMC 17.44.040; 17.44.090(A) A up to 4 EMC 17.44.030(A) —
Minimum lot size
8,400 sq ft EMC 18.04.040(G)(1); 18.04.020(A); 18.04.020(G)(1)
Minimum lot width
60 ft EMC 18.04.040(G)(1); 18.04.020(G)(2)
Subdivision EMC 17.20.060; 17.20.080(A) H 5 or more EMC 17.20.010 —
Minimum lot size
8,400 sq ft EMC 18.04.040(G)(1); 18.04.020(A); 18.04.020(G)(1)
Minimum lot width
60 ft EMC 18.04.040(G)(1); 18.04.020(G)(2)
Lot size averaging EMC 17.18.050 A —
Minimum average lot size
8,400 sq ft EMC 17.18.050(A); 18.04.040(G)(1); 18.04.020(A)
Minimum lot size
0.95 × 8,400 sq ft EMC 17.18.050(A)(2)
Zero lot line planned development EMC 18.08.300 H —
Minimum parent area
217,800 sq ft EMC 18.08.330(A)
Minimum lot size
3,000 sq ft EMC 18.08.330(B)
Planned unit development EMC 17.17.010; 18.04.190(A); 18.04.190(E)(5) H — The density of residential development for PUDs shall be based on the gross density of the underlying zoning district. The planning commission may recommend a dwelling unit density not more than 20 percent greater than that permitted by the underlying zone EMC 18.04.190(D)
Minimum lot size
No limit EMC 18.04.190(C)(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. No other permanent supportive housing, transitional housing, emergency housing or emergency shelter is within 880 feet
  2. All of these are true:
    • No other class II or III group home is within 600 feet
    • No school, church, park, playground or other sensitive use is within 1,000 feet
  3. None of these is true:
    • The rear yard abuts an alley
  4. The rear yard abuts an alley
  5. Floor area of one unit is at most 400
  6. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at most 49
  7. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at least 50