Sign in

MR-2 · Mixed Residential 2

Edgewood, WA · EMC 18.80.050 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Dwelling
Home✓ ADU✓
————
Live/Work Unit
HomeA ADU—
————
Work/Live Unit
HomeA ADU—
————
Duplex—
Home✓ ADU—
———
Stacked Flats—
Home✓ ADU—
———
Cottage Housing—
Home✓ ADU—
———
Courtyard Apartments—
Home✓ ADU—
———
Multi-plex (tri-. four-. fixe-, six-)——
Home✓ ADU—
Home✓ ADU—
—
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Adult Family Home————
Home✓ ADU—
Nursing and Residential Care Facilities————
HomeA ADU—
Assisted Living Facilities————
HomeA ADU—
Permanent Supportive Housing————
Home✓ ADU—
Transitional Housing————
Home✓ ADU—
Co-living————
Home✓1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units2 units, ADUs included EMC 18.80.050(C)(1)(a); 18.90.190(E)(1)
6 units EMC 18.20.160
for Multi-plex (tri-. four-. fixe-, six-) (4+ units)
Not set EMC 18.80.050
for Townhouse (4+ units)
Minimum lot size3,200 sq ft EMC 18.80.050(C)(2)(a)(ii)
Minimum frontage
  • 20 ft2 EMC 18.90.100(C)(1)
  • 50 ft3 EMC 18.80.050(C)(5)
Maximum densityNot set EMC 18.80.050(C)(1)(a)
  • 8 units per acre, on the net lot area4 EMC 18.80.050(C)(1)(b)(ii); 18.90.040
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area5 EMC 18.90.080(E)(2)
for Multi-plex (tri-. four-. fixe-, six-) (3, 4+ units); Townhouse (3, 4+ units)
Non-Multifamily: The permitted unit density is two principal units per lot. EMC 18.80.050(C)(1)(a)
for Adult Family Home (group living); Nursing and Residential Care Facilities (group living); Assisted Living Facilities (group living); Permanent Supportive Housing (group living); Transitional Housing (group living); Co-living (group living)1
Maximum residentsNot set EMC 18.20
  • 8 persons6 EMC 18.20.040
  • 6 persons7 EMC 18.20.040
for Adult Family Home (group living)
Maximum sleeping unitsNot set EMC 18.20
4 × ((8 × lot area minus critical areas and buffers) ÷ 43,560, rounded down) sleeping units EMC 18.80.050(C)(1)(b)(ii); 18.90.040; EMC 18.100.140(D)
for Co-living (group living)1

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft2 EMC 18.90.100(C)
  • 15 ft3 EMC 18.80.050(C)(4)(a)(i)
Side setback
  • 20 ft2 EMC 18.90.100(C)
  • 0 ft3 EMC 18.80.050(C)(4)(a)(vii)
Street side setback15 ft EMC 18.80.050(C)(4)(a)(i); 18.90.100(A)
Rear setback
  • 20 ft2 EMC 18.90.100(C)
  • 0 ft8 EMC 18.80.050(C)(4)(a)(v)
  • 10 ft9 EMC 18.80.050(C)(4)(a)(iv)
Maximum height35 ft EMC 18.80.050(C)(6)
Maximum storiesNot set EMC 18.80.050
3 stories EMC 18.20.220
for Stacked Flats (2 units)
Maximum lot coverage55% EMC 18.80.050(C)(3)(b)(i)
Maximum impervious surface60% EMC 18.80.050(C)(3)(b)(ii)
Minimum parking
  • 0 spaces per unit10 EMC 18.90.130(J) Table 1 note 2
  • 1 space per unit11 EMC 18.90.130(J) Table 1
  • 2 spaces per unit12 EMC 18.90.130(J) Table 1
2 spaces per unit EMC 18.90.130(J) Table 1
for Detached Dwelling (1 unit)
One per business use in addition to the residential use EMC 18.90.130(J) Table 1
for Live/Work Unit (1 unit); Work/Live Unit (1 unit)
  • 0.75 spaces per unit13 EMC 18.90.130(J) Table 1 note 3(a)
  • 1.5 spaces per unit14 EMC 18.90.130(J) Table 1
for Multi-plex (tri-. four-. fixe-, six-) (3, 4+ units); Townhouse (3, 4+ units)
  • 0 spaces per bed13 EMC 18.90.130(J) Table 1 note 4
  • (beds in the project ÷ 3) + employees on the largest shift spaces14 EMC 18.90.130(J) Table 1
for Adult Family Home (group living); Assisted Living Facilities (group living)
  • 0 spaces per bed13 EMC 18.90.130(J) Table 1 note 4
  • 0.25 spaces per bed14 EMC 18.90.130(J) Table 1
for Nursing and Residential Care Facilities (group living)
The requirements for any use not listed herein shall be determined by the Director or designee based upon the requirements for the most comparable use specified in this section. EMC 18.90.130(J)(1)
for Permanent Supportive Housing (group living); Transitional Housing (group living)
  • 0 spaces per sleeping unit15 EMC 18.100.140(F)(2)
  • 0.25 spaces per sleeping unit16 EMC 18.100.140(F)(1)
for Co-living (group living)1
Maximum unit sizeNot set EMC 18.80.050
1,600 sq ft EMC 18.95.050(J)(2)
for Cottage Housing (2 units)
300 sq ft EMC 18.100.140(G)(1)(a)
for Co-living (group living)1
Minimum open spaceNot set EMC 18.80.050
20% EMC 18.95.050(J)(3)
for Cottage Housing (2 units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units EMC 18.90.190(E)(1)

Building

StandardValueExceptions
Front setback
  • 20 ft2 EMC 18.90.100(C); EMC 18.90.190(E)(4)
  • 15 ft3 EMC 18.80.050(C)(4)(a)(i); EMC 18.90.190(E)(4)
Side setback
  • 20 ft2 EMC 18.90.100(C); EMC 18.90.190(E)(4)
  • 0 ft3 EMC 18.80.050(C)(4)(a)(vii); EMC 18.90.190(E)(4)
Rear setback
  • 20 ft2 EMC 18.90.100(C); EMC 18.90.190(E)(4)
  • 0 ft8 EMC 18.80.050(C)(4)(a)(v); EMC 18.90.190(E)(4)
  • 10 ft9 EMC 18.80.050(C)(4)(a)(iv); EMC 18.90.190(E)(4)
Maximum heightFor detached ADUs, the building height of the ADU shall not be greater than the principal unit's building height or 24 feet, whichever is greater. EMC 18.90.190(E)(5)
Minimum parking
  • 0 spaces per unit17 EMC 18.90.130(J) Table 1 note 1
  • 1 space per unit18 EMC 18.90.130(J) Table 1
  • 2 spaces per unit19 EMC 18.90.130(J) Table 1
Maximum unit sizethe smallest of the largest of 1,000, 0.8 × floor area of the main house, 1,600 sq ft EMC 18.90.190(E)(3)
Attached to the main houseNot required EMC 18.90.190(E)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short EMC 16.03.050 A up to 6 EMC 16.03.020 —
Minimum lot size
3,200 sq ft EMC 18.80.050(C)(2)(a)(ii)
Minimum lot width
Not set EMC 18.80.050(C)
Minimum frontage
  • 20 ft2 EMC 18.90.100(C)(1)
  • 50 ft3 EMC 18.80.050(C)(5)
Subdivision, full EMC 16.04.030(A) H 7 or more EMC 16.04.020 —
Minimum lot size
3,200 sq ft EMC 18.80.050(C)(2)(a)(ii)
Minimum lot width
Not set EMC 18.80.050(C)
Minimum frontage
  • 20 ft2 EMC 18.90.100(C)(1)
  • 50 ft3 EMC 18.80.050(C)(5)
Unit lot subdivision EMC 16.08.040Only for: Detached Dwelling, Duplex, Cottage Housing, Courtyard Apartments, Townhouse A up to 6 EMC 16.08.020(A); 16.03.020 —
Minimum lot size
Not set EMC 16.08.060(A)
Residential cluster development EMC 18.50.035(B)(4) H — The maximum density of the underlying zoning district shall apply. Density is based on the net buildable area as prescribed in EMC § 18.90.040. EMC 18.50.035(C)(1)
Minimum lot size
3,000 sq ft EMC 18.50.035(C)(2)(b)
Binding site plan EMC 16.05.050(B) A20 —
Maximum units
4 units EMC 16.05.050(B)
Minimum lot size
Not set EMC 16.05.030
Binding site plan EMC 16.05.050(A) H21 —
Minimum units
5 units EMC 16.05.050(A)
Minimum lot size
Not set EMC 16.05.030

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot area minus critical areas and buffers is at least 32,670 sf
  2. The lot is a flag lot
  3. None of these is true:
    • The lot is a flag lot
  4. None of these is true:
    • The project uses the inclusionary density bonus (on-site low-income and/or below market rate units)
  5. The project uses the inclusionary density bonus (on-site low-income and/or below market rate units)
  6. The adult family home has approval from the state to serve up to eight adults
  7. None of these is true:
    • The adult family home has approval from the state to serve up to eight adults
  8. All of these are true:
    • The rear lot line abuts an alley
    None of these is true:
    • The lot is a flag lot
  9. None of these is true:
    • The lot is a flag lot
    • The rear lot line abuts an alley
  10. Within one-half mile of a major transit stop
  11. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Within one-half mile of a major transit stop
  12. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Within one-half mile of a major transit stop
  13. Within one-half mile of a transit stop that receives transit service at least four times per hour for 12 or more hours per day
  14. None of these is true:
    • Within one-half mile of a transit stop that receives transit service at least four times per hour for 12 or more hours per day
  15. Within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  16. None of these is true:
    • Within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  17. All of these are true:
    • Within one-half mile of a major transit stop
    • The Director determines that adequate provision of on-street parking facilities is available
  18. All of these are true:
    • Not all of these are true:
      • Within one-half mile of a major transit stop
      • The Director determines that adequate provision of on-street parking facilities is available
    • Lot area is at most 6,000 sf
  19. All of these are true:
    • Not all of these are true:
      • Within one-half mile of a major transit stop
      • The Director determines that adequate provision of on-street parking facilities is available
    • Lot area is more than 6,000 sf
  20. All of these are true:
    • Any of these is true:
      • Division of land for the sale or lease of industrial or commercial property
      • Division of land that includes land to be created as condominium ownership under Chapter 64.34 RCW
    • Main dwelling units on the lot is at most 4
  21. All of these are true:
    • Any of these is true:
      • Division of land for the sale or lease of industrial or commercial property
      • Division of land that includes land to be created as condominium ownership under Chapter 64.34 RCW
    • Main dwelling units on the lot is at least 5