Sign in

NCH · Neighborhood Centers and Hubs

Edmonds, WA · ECDC 16.120 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling (unit)
Home✓ ADU✓1
————
Live/work unit
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Multi-family housing—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Middle housing—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Co-living housing————
Home✓2 ADU—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—
Emergency shelter————
Home✓3 ADU—
Emergency housing————
Home✓3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

No standards.

3. Building standards

StandardValueExceptions
Front setback7 ft ECDC 16.120.050(A)(2); 16.120.050(B)
Maximum front setback15 ft ECDC 16.120.050(B); 16.120.020; 16.120.070(D)(1)(b)
Not set ECDC 16.120.050(B)
for Single-family dwelling (unit) (1 unit)
Side setback
  • 10 ft4 ECDC 16.120.050(B)
  • 0 ft5 ECDC 16.120.050(B)
Street side setback7 ft ECDC 16.120.050(A)(2); 16.120.050(B); 21.90.130; 21.90.140
Rear setback
  • Rear setback: Equal to the required rear setback of the abutting LDR zone overlay.4 ECDC 16.120.050(B)
  • 0 ft5 ECDC 16.120.050(B)
Maximum height
  • 30 ft6 ECDC 16.120.050(B)
  • 30 ft7 ECDC 16.120.050(B)
  • 33 ft8 ECDC 16.120.050(B)
  • 35 ft9 ECDC 16.120.050(B); 16.120.090(C)
  • 38 ft10 ECDC 16.120.050(B); 16.120.090(C)
  • 30 ft11 ECDC 16.120.050(B)
  • 33 ft12 ECDC 16.120.050(B)
  • 40 ft13 ECDC 16.120.050(B); 16.120.090(D)
  • 43 ft14 ECDC 16.120.050(B); 16.120.090(D)
  • 35 ft15 ECDC 16.120.050(B); 16.120.090(C)
  • 38 ft16 ECDC 16.120.050(B); 16.120.090(C)
  • 40 ft17 ECDC 16.120.050(B)
  • 43 ft18 ECDC 16.120.050(B)
  • 50 ft19 ECDC 16.120.050(B); 16.120.090(D)
  • 53 ft20 ECDC 16.120.050(B); 16.120.090(D)
  • 45 ft21 ECDC 16.120.050(B); 16.120.090(C)
  • 48 ft22 ECDC 16.120.050(B); 16.120.090(C)
25 ft ECDC 16.120.050(A)(2)(a); 16.20.030(D)
for Single-family dwelling (unit) (1 unit)
Maximum lot coverageNot set ECDC 16.120.050(B)
35% ECDC 16.120.050(A)(2)(a); 16.20.030(D)
for Single-family dwelling (unit) (1 unit)
Minimum parking
  • 1 space per unit23 ECDC 16.120.080(B)(2)(a)
  • 1.25 spaces per unit24 ECDC 16.120.080(B)(2)(b)
  • 1.75 spaces per unit25 ECDC 16.120.080(B)(2)(c)
  • 0 spaces per unit26 ECDC 16.120.080(B)(1); 16.20.045(B)(1)
  • 1 space per unit27 ECDC 16.120.080(B)(1); 16.20.045(B)(2)
  • 2 spaces per unit28 ECDC 16.120.080(B)(1); 16.20.045(B)(3)
for Single-family dwelling (unit) (1 unit)
  • 0 spaces per sleeping unit26 ECDC 17.50.020(A)(2)
  • 0.25 spaces per sleeping unit29 ECDC 17.50.020(A)(2)
for Co-living housing (group living)2
Minimum open space15% ECDC 16.120.060(A)
Maximum units per buildingNot set ECDC 16.120.050(B)
1 unit ECDC 16.20.050(D)(4)
for Single-family dwelling (unit) (1 unit)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units ECDC 16.120.050(A)(2); 16.20.060(B)

Building

StandardValueExceptions
Front setback7 ft ECDC 16.120.050(A)(2); 16.120.050(B)
Side setback
  • 10 ft4 ECDC 16.120.050(B)
  • 0 ft5 ECDC 16.120.050(B)
Rear setback
  • 0 ft30 ECDC 16.120.050(A)(2); 16.20.060(C)
  • 10 ft31 ECDC 16.120.050(A)(2); 16.20.060(C)
  • 20 ft32 ECDC 16.120.050(A)(2); 16.20.060(C)
  • 0 ft33 ECDC 16.120.050(B)
Maximum height
  • 24 ft34 ECDC 16.120.050(A)(2); 16.20.060(C)
  • 25 ft33 ECDC 16.120.050(A)(2); 16.20.060(A); 16.20.030(D)
Minimum parking
  • 0 spaces per unit26 ECDC 16.120.050(A)(2); 16.20.060(C)
  • the largest of 0, ADUs on the lot − 1 spaces29 ECDC 16.120.050(A)(2); 16.20.060(C)
Maximum unit size1,200 sq ft ECDC 16.120.050(A)(2); 16.20.060(C)
Attached to the main houseNot required ECDC 16.120.050(A)(2); 16.20.060(B)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision ECDC 20.75.030(C); 20.01.003(A) A up to 4 ECDC 20.75.030(C) —
Minimum lot size
Not set ECDC 16.120.050
Formal subdivision ECDC 20.75.030(B); 20.01.003(A)-(B) H 5 or more ECDC 20.75.030(B) —
Minimum lot size
Not set ECDC 16.120.050
Unit lot subdivision ECDC 20.75.045(K); 20.01.003(A)Only for: Single-family dwelling (unit), Middle housing A up to 4 ECDC 20.75.045(K) —
Minimum lot size
Unit lot subdivisions determine compliance with the relevant dimensional standards of ECDC Title 16 by analyzing whether the parent lot complies, but not requiring that each newly created lot within the unit lot subdivision (the unit lot) complies, with those dimensional standards. ECDC 20.75.045(A); 20.75.045(D)
Unit lot subdivision ECDC 20.75.045(K); 20.01.003(A)-(B)Only for: Single-family dwelling (unit), Middle housing H 5 or more ECDC 20.75.045(K) —
Minimum lot size
Unit lot subdivisions determine compliance with the relevant dimensional standards of ECDC Title 16 by analyzing whether the parent lot complies, but not requiring that each newly created lot within the unit lot subdivision (the unit lot) complies, with those dimensional standards. ECDC 20.75.045(A); 20.75.045(D)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. An existing single-family home is on the lot
  2. Any of these is true:
    • None of these is true:
      • Lot is in the commercial ground floor overlay (GFCO) map
    • Ground-floor commercial uses occupy at least 60 percent of the street-facing frontage to a depth of 45 feet
  3. Lot is in the Westgate, Medical District Expansion or Five Corners center, where hotels are allowed
  4. The lot line is adjacent to LDR-zoned property
  5. None of these is true:
    • The lot line is adjacent to LDR-zoned property
  6. The portion of the building is within 20 feet of an LDR-zoned lot
  7. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is none
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  8. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is none
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  9. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is green_building
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  10. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is green_building
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  11. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch4
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is none
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  12. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch4
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is none
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  13. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch4
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is community_benefit
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  14. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch4
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is community_benefit
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  15. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch4
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is green_building
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  16. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch4
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is green_building
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  17. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch5
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is none
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  18. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch5
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is none
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  19. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch5
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is community_benefit
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  20. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch5
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is community_benefit
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  21. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch5
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is green_building
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
    • Project is a ground floor commercial project
  22. All of these are true:
    • NCH overlay of the lot: base NCH, NCH-4 (MU-4) or NCH-5 (MU-5) is nch5
    • Bonus height incentive used: none, community benefit (NCH-4 and NCH-5 only) or green building is green_building
    • Project is a ground floor commercial project
    None of these is true:
    • The portion of the building is within 20 feet of an LDR-zoned lot
  23. Floor area of one unit is less than 800
  24. All of these are true:
    • Floor area of one unit is at least 800
    • Floor area of one unit is at most 1,200
  25. Floor area of one unit is more than 1,200
  26. Lot is within one-half mile walking distance of a major transit stop
  27. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  28. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  29. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  30. All of these are true:
    • The accessory dwelling unit is detached from the principal dwelling
    • The rear lot line abuts an alley
  31. All of these are true:
    • The accessory dwelling unit is detached from the principal dwelling
    • Building height is at most 15
    None of these is true:
    • The rear lot line abuts an alley
  32. All of these are true:
    • The accessory dwelling unit is detached from the principal dwelling
    • Building height is more than 15
    None of these is true:
    • The rear lot line abuts an alley
  33. None of these is true:
    • The accessory dwelling unit is detached from the principal dwelling
  34. The accessory dwelling unit is detached from the principal dwelling