Sign in

GO · GO General Office District

Enumclaw, WA · EMC 18.14 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit, single-family detached (one unit per structure)
HomeH ADU—
————
Multifamily development (3+ units per structure)——
Home✓1 ADU—
Home✓1 ADU—
—
Adult family home protected by state and federal law————
Home✓ ADU—
Transitional housing————
HomeH2 ADU—
Permanent supportive housing————
HomeH2 ADU—
Co-living housing————
Home✓1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size10,000 sq ft EMC 18.06.040(A); 18.14.040
Minimum lot width70 ft EMC 18.06.040(A)
Minimum frontage30 ft EMC 18.06.040(A)
Maximum density
  • 15 units per acre3 EMC 18.06.040(A); 18.06.040(B)(1)
  • 1 unit per 2,900 sq ft4 EMC 19.38.210(A)
  • 1 unit per 2,200 sq ft5 EMC 19.38.210(B)
15 units per acre EMC 18.06.040(A)
for Dwelling unit, single-family detached (one unit per structure) (1 unit); Adult family home protected by state and federal law (group living)
1 unit per the largest of 43,560 ÷ 15, lot area ÷ 10 sq ft EMC 18.06.040(A); 18.05.020(B)(7)
for Transitional housing (group living)2; Permanent supportive housing (group living)2
Maximum sleeping unitsNot set EMC 18.06.040(A)
  • (60 × lot area) ÷ 43,560, rounded down sleeping units3 EMC 18.06.040(A); 18.06.040(B)(1); 19.32.180(B)(5)
  • (4 × lot area) ÷ 2,900, rounded down sleeping units4 EMC 19.38.210(A); 19.32.180(B)(5)
  • (4 × lot area) ÷ 2,200, rounded down sleeping units5 EMC 19.38.210(B); 19.32.180(B)(5); 19.32.180(D)
for Co-living housing (group living)1

3. Building standards

StandardValueExceptions
Front setback20 ft EMC 18.06.040(A)
Side setback7.5 ft EMC 18.06.040(A)
  • 9 ft6 EMC 19.38.230(A)(1)
  • 14 ft7 EMC 19.38.230(A)(1)
for Multifamily development (3+ units per structure) (3, 4+ units)1; Co-living housing (group living)1
Rear setback25 ft EMC 18.06.040(A)
15 ft EMC 19.38.230(A)(1)
for Multifamily development (3+ units per structure) (3, 4+ units)1; Co-living housing (group living)1
Maximum height30 ft EMC 18.06.040(A)
35 ft EMC 19.38.220(A)
for Multifamily development (3+ units per structure) (3, 4+ units)1; Co-living housing (group living)1
Maximum lot coverage45% EMC 18.06.040(A)
Minimum parking(0.33 × beds in the project) + employees on the largest shift, rounded spaces EMC 19.14.070
  • 2 spaces per unit8 EMC 19.14.070
  • 1 space per unit9 EMC 19.14.070
for Dwelling unit, single-family detached (one unit per structure) (1 unit)
1 space per unit EMC 19.38.270(A)(1)
for Multifamily development (3+ units per structure) (3, 4+ units)1
  • 0 spaces per sleeping unit10 EMC 19.32.180(B)(4)
  • 0.25 spaces per sleeping unit11 EMC 19.32.180(B)(4)
for Co-living housing (group living)1
Maximum unit sizeNot set EMC 18.06.040(A)
600 sq ft EMC 19.32.180(B)(1)
for Co-living housing (group living)1
Minimum open spaceNot set EMC 18.06.040(A)
((200 × main dwelling units on the lot) ÷ lot area) × 100% EMC 19.38.280(A)(1)
for Multifamily development (3+ units per structure) (3, 4+ units)1
Open space shall be provided at a minimum of 10 square feet for each 100 square feet of sleeping unit space. EMC 19.32.180(B)(3)
for Co-living housing (group living)1

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision EMC 17.08.010 A up to 4 EMC 17.04.050 —
Minimum lot size
10,000 sq ft EMC 18.06.040(A); 17.08.120
Minimum lot width
70 ft EMC 17.16.230(A)(4); 18.06.040(A)
Minimum frontage
30 ft EMC 18.06.040(A)
Subdivision EMC 17.12.010 H 5 or more EMC 17.04.050 —
Minimum lot size
10,000 sq ft EMC 18.06.040(A); 17.08.120
Minimum lot width
70 ft EMC 17.16.230(A)(4); 18.06.040(A)
Minimum frontage
30 ft EMC 18.06.040(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Included within a mixed use development approved under Chapter 19.38 EMC
  2. None of these is true:
    • Within a quarter mile of another property that contains permanent supportive housing or transitional housing
    • Within a quarter mile of emergency housing or an emergency shelter
  3. None of these is true:
    • Mixed use development where residential uses are horizontally separated from nonresidential uses
  4. All of these are true:
    • Mixed use development where residential uses are horizontally separated from nonresidential uses
    None of these is true:
    • At least 20 percent of the units are affordable housing per EMC 19.38.330(B)(1)
  5. All of these are true:
    • Mixed use development where residential uses are horizontally separated from nonresidential uses
    • At least 20 percent of the units are affordable housing per EMC 19.38.330(B)(1)
  6. Building stories is at most 2
  7. Building stories is more than 2
  8. Bedrooms in one unit is at least 2
  9. Bedrooms in one unit is less than 2
  10. Within one-half-mile walking distance of a major transit stop
  11. None of these is true:
    • Within one-half-mile walking distance of a major transit stop