Sign in

NB · NB Neighborhood Business District

Enumclaw, WA · EMC 18.20 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit, live-work
Home✓1 H2 ADU—
Home✓1 H2 ADU—
Home✓1 H2 ADU—
Home✓1 H2 ADU—
—
Adult family home protected by state and federal law————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size10,000 sq ft EMC 18.06.040(A); 18.20.040
Minimum lot widthNo limit EMC 18.06.040(A)
Maximum density1 unit per 10,000 sq ft EMC 18.06.040(A)

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft3 EMC 18.06.040(A)
  • 30 ft4 EMC 18.06.040(B)(2)
  • 35 ft5 EMC 18.20.090(B)
Side setback
  • 0 ft6 EMC 18.06.040(B)(4)(a)
  • When parcels directly abut a residential-zoned property, the setback along the abutting residential property shall adhere to the residential setback standards.7 EMC 18.06.040(B)(4)(b)
Street side setback
  • 35 ft5 EMC 18.20.090(B)
  • 30 ft4 EMC 18.06.040(B)(2)
  • 10 ft8 EMC 18.06.040(B)(4)(a)
Rear setback
  • 0 ft6 EMC 18.06.040(B)(4)(a)
  • When parcels directly abut a residential-zoned property, the setback along the abutting residential property shall adhere to the residential setback standards.7 EMC 18.06.040(B)(4)(b)
Maximum height30 ft EMC 18.06.040(A)
Maximum lot coverage40% EMC 18.06.040(A)
Minimum parking1 space per unit EMC 18.05.020(B)(5)
  • 2 spaces per unit9 EMC 19.14.070
  • 1 space per unit10 EMC 19.14.070
for Dwelling unit, live-work (1, 2, 3, 4+ units)2
(0.33 × beds in the project) + employees on the largest shift, rounded spaces EMC 19.14.070
for Adult family home protected by state and federal law (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision EMC 17.08.010 A up to 4 EMC 17.04.050 —
Minimum lot size
10,000 sq ft EMC 18.06.040(A); 17.08.120
Minimum lot width
No limit EMC 17.08.120; 18.06.040(A)
Subdivision EMC 17.12.010 H 5 or more EMC 17.04.050 —
Minimum lot size
10,000 sq ft EMC 18.06.040(A); 17.08.120
Minimum lot width
No limit EMC 17.16.230(A)(4); 18.06.040(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Dwellings or living quarters are located above the primary use
  2. None of these is true:
    • Dwellings or living quarters are located above the primary use
  3. None of these is true:
    • Corner lot
    • Directly across the street from a residential district on the comprehensive plan, not separated by a street of 80 ft or more right-of-way
  4. All of these are true:
    • Corner lot
    None of these is true:
    • Directly across the street from a residential district on the comprehensive plan, not separated by a street of 80 ft or more right-of-way
  5. Directly across the street from a residential district on the comprehensive plan, not separated by a street of 80 ft or more right-of-way
  6. None of these is true:
    • Directly abuts residential-zoned property (applies along that line)
  7. Directly abuts residential-zoned property (applies along that line)
  8. None of these is true:
    • Directly across the street from a residential district on the comprehensive plan, not separated by a street of 80 ft or more right-of-way
    • Corner lot
  9. Bedrooms in one unit is at least 2
  10. Bedrooms in one unit is less than 2