Sign in

R-2 · R-2 Moderate Density Single-Family Residential District

Enumclaw, WA · EMC 18.08 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit, single-family detached (one unit per structure)
Home✓ ADU✓
————
Dwelling unit cottage, single-family detached (one unit per structure)
Home✓ ADU✓
————
Dwelling unit, duplex (two units per structure)—
Home✓1 ✓2 H3 ADU✓1 ✓2 ✓3
———
Cottage housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Adult family home protected by state and federal law————
Home✓ ADU✓
Transitional housing————
HomeH4 ADU✓4
Permanent supportive housing————
HomeH4 ADU✓4

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size8,400 sq ft EMC 18.06.030(A); EMC 18.08.040
3,000 sq ft EMC 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Minimum lot widthNot set EMC 18.06.030(A)
40 ft EMC 19.46.050(A)(2)(c)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Minimum frontage50 ft EMC 18.06.030(A)
Maximum densityNo limit EMC 18.06.030(A)
The number of transitional housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property; provided, that in no case shall the number of transitional housing units allowed on any given property exceed 10. EMC 18.05.020(B)(7)
for Transitional housing (group living)4
The number of permanent supportive housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property; provided, that in no case shall the number of permanent supportive housing units allowed on any given property exceed 10. EMC 18.05.020(B)(8)
for Permanent supportive housing (group living)4

3. Building standards

StandardValueExceptions
Front setback20 ft EMC 18.06.030(A)
15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Side setback9 ft EMC 18.06.030(A)
5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Rear setback25 ft EMC 18.06.030(A)
15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Maximum height30 ft EMC 18.06.030(A)
Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Maximum storiesNot set EMC 18.06.030(A)
1 story EMC 19.46.040
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit); Dwelling unit, duplex (two units per structure) (2 units)1
Maximum lot coverage40% EMC 18.06.030(A)
Minimum parking
  • 2 spaces per unit5 EMC 19.14.070
  • 1 space per unit6 EMC 19.14.070
(1.35 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5, rounded down), rounded up spaces EMC 19.40.020(A); 19.40.040(D)(4)
for Dwelling unit, duplex (two units per structure) (2 units)3; Cottage housing (2, 3, 4+ units)
(0.33 × beds in the project) + employees on the largest shift, rounded spaces EMC 19.14.070
for Adult family home protected by state and federal law (group living); Transitional housing (group living)4; Permanent supportive housing (group living)4
Maximum unit sizeNot set EMC 18.06.030(A)
  • 1,350 sq ft7 EMC 19.46.040; 19.46.050(A)(2)(a)
  • 2,000 sq ft8 EMC 19.46.040; 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Maximum building floor areaNot set EMC 18.06.030(A)
2,500 sq ft EMC 18.05.020(B)(3)
for Dwelling unit, duplex (two units per structure) (2 units)1
Maximum lot size18,000 sq ft EMC 18.06.030(A)
8,399 sq ft EMC 19.46.050(A)(2)(e)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units EMC 19.34.020; 19.34.070(B)
Minimum lot sizeNo limit EMC 19.34.050

Building

StandardValueExceptions
Front setback20 ft EMC 19.34.050; 19.34.100(A); 18.06.030(A)
15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Side setback
  • 9 ft9 EMC 19.34.050; 19.34.100(A); 18.06.030(A)
  • 7.5 ft10 EMC 19.34.050; 18.06.030(A)
5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Rear setback
  • 25 ft9 EMC 19.34.050; 19.34.100(A); 18.06.030(A)
  • 7.5 ft11 EMC 19.34.050; 18.06.030(A)
  • 0 ft12 EMC 19.34.100(C)
  • 15 ft13 EMC 19.46.050(A)(2)(b)
  • 0 ft12 EMC 19.34.100(C)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Maximum height
  • 30 ft9 EMC 19.34.050; 19.34.100(A); 18.06.030(A)
  • 24 ft10 EMC 19.34.100(B)
Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit)
Minimum parking
  • 0 spaces per unit14 EMC 19.34.100(D)
  • 1 space per unit15 EMC 19.34.100(D)
Maximum unit size1,000 sq ft EMC 19.34.070(A)
Attached to the main houseNot required EMC 19.34.070(B)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision EMC 17.08.010 A up to 4 EMC 17.04.050 —
Minimum lot size
8,400 sq ft EMC 18.06.030(A); 17.08.120
Maximum lot size
18,000 sq ft EMC 18.06.030(A)
Minimum frontage
50 ft EMC 18.06.030(A)
Short subdivision EMC 18.06.030(B)(1); 17.08.010 A16 up to 4 EMC 17.04.050 —
Minimum lot size
8,400 sq ft EMC 18.06.030(A); 17.08.120
Maximum lot size
18,000 sq ft EMC 18.06.030(A)
Minimum frontage
50 ft EMC 18.06.030(A)
Subdivision EMC 17.12.010 H 5 or more EMC 17.04.050 —
Minimum lot size
8,400 sq ft EMC 18.06.030(A); 17.08.120
Maximum lot size
18,000 sq ft EMC 18.06.030(A)
Minimum lot width
50 ft EMC 17.16.230(A)(4)
Minimum frontage
50 ft EMC 18.06.030(A)
Subdivision EMC 17.12.010 H 10 or more EMC 17.16.230(B)
Minimum average lot size
8,400 sq ft EMC 17.16.230(B)
Minimum lot size
8,400 sq ft EMC 18.06.030(A); 17.08.120
Maximum lot size
18,000 sq ft EMC 18.06.030(A)
Minimum lot width
50 ft EMC 17.16.230(A)(4)
Minimum frontage
50 ft EMC 18.06.030(A)
Cottage lot EMC 19.46.030; 17.08.010Only for: Dwelling unit cottage, single-family detached (one unit per structure) A — No limit EMC 19.46.030
Minimum lot size
3,000 sq ft EMC 19.46.050(A)(2)(a)
Maximum lot size
8,399 sq ft EMC 19.46.050(A)(2)(e)
Minimum lot width
40 ft EMC 19.46.050(A)(2)(c)
Maximum units per lot
1 unit EMC 19.46.050(A)(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
  2. All of these are true:
    • Conversion of an existing single-family dwelling to a duplex
    None of these is true:
    • New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
  3. None of these is true:
    • New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
    • Conversion of an existing single-family dwelling to a duplex
  4. None of these is true:
    • Within a quarter mile of another property that contains permanent supportive housing or transitional housing
    • Within a quarter mile of emergency housing or an emergency shelter
  5. Bedrooms in one unit is at least 2
  6. Bedrooms in one unit is less than 2
  7. Lot area is less than 6,200 sf
  8. Lot area is at least 6,200 sf
  9. None of these is true:
    • The accessory dwelling unit is detached from the principal unit
  10. The accessory dwelling unit is detached from the principal unit
  11. All of these are true:
    • The accessory dwelling unit is detached from the principal unit
    None of these is true:
    • The rear lot line abuts an alley
  12. All of these are true:
    • The accessory dwelling unit is detached from the principal unit
    • The rear lot line abuts an alley
  13. Not all of these are true:
    • The accessory dwelling unit is detached from the principal unit
    • The rear lot line abuts an alley
  14. Within one-half-mile walking distance of a major transit stop
  15. None of these is true:
    • Within one-half-mile walking distance of a major transit stop
  16. All lots surrounding the parcel to be short platted are substantially greater than the minimum 8,400 square feet