R-2 · R-2 Moderate Density Single-Family Residential District
Enumclaw, WA · EMC 18.08 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling unit, single-family detached (one unit per structure) | Home✓ ADU✓ | — | — | — | — |
| Dwelling unit cottage, single-family detached (one unit per structure) | Home✓ ADU✓ | — | — | — | — |
| Dwelling unit, duplex (two units per structure) | — | — | — | — | |
| Cottage housing | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Adult family home protected by state and federal law | — | — | — | — | Home✓ ADU✓ |
| Transitional housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 8,400 sq ft EMC 18.06.030(A); EMC 18.08.040 | 3,000 sq ft EMC 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Minimum lot width | Not set EMC 18.06.030(A) | 40 ft EMC 19.46.050(A)(2)(c)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Minimum frontage | 50 ft EMC 18.06.030(A) | |
| Maximum density | No limit EMC 18.06.030(A) | The number of transitional housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property; provided, that in no case shall the number of transitional housing units allowed on any given property exceed 10. EMC 18.05.020(B)(7)
for Transitional housing (group living)4 The number of permanent supportive housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property; provided, that in no case shall the number of permanent supportive housing units allowed on any given property exceed 10. EMC 18.05.020(B)(8)
for Permanent supportive housing (group living)4 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft EMC 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Side setback | 9 ft EMC 18.06.030(A) | 5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Rear setback | 25 ft EMC 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum height | 30 ft EMC 18.06.030(A) | Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum stories | Not set EMC 18.06.030(A) | 1 story EMC 19.46.040
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit); Dwelling unit, duplex (two units per structure) (2 units)1 |
| Maximum lot coverage | 40% EMC 18.06.030(A) | |
| Minimum parking | (1.35 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5, rounded down), rounded up spaces EMC 19.40.020(A); 19.40.040(D)(4)
| |
| Maximum unit size | Not set EMC 18.06.030(A) | |
| Maximum building floor area | Not set EMC 18.06.030(A) | 2,500 sq ft EMC 18.05.020(B)(3)
for Dwelling unit, duplex (two units per structure) (2 units)1 |
| Maximum lot size | 18,000 sq ft EMC 18.06.030(A) | 8,399 sq ft EMC 19.46.050(A)(2)(e)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units EMC 19.34.020; 19.34.070(B) | |
| Minimum lot size | No limit EMC 19.34.050 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft EMC 19.34.050; 19.34.100(A); 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Side setback | 5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) | |
| Rear setback | ||
| Maximum height | Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft EMC 19.34.070(A) | |
| Attached to the main house | Not required EMC 19.34.070(B) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision EMC 17.08.010 | A | up to 4 EMC 17.04.050 | — | Minimum lot size 8,400 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 18,000 sq ft EMC 18.06.030(A) Minimum frontage 50 ft EMC 18.06.030(A) |
| Short subdivision EMC 18.06.030(B)(1); 17.08.010 | A16 | up to 4 EMC 17.04.050 | — | Minimum lot size 8,400 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 18,000 sq ft EMC 18.06.030(A) Minimum frontage 50 ft EMC 18.06.030(A) |
| Subdivision EMC 17.12.010 | H | 5 or more EMC 17.04.050 | — | Minimum lot size 8,400 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 18,000 sq ft EMC 18.06.030(A) Minimum lot width 50 ft EMC 17.16.230(A)(4) Minimum frontage 50 ft EMC 18.06.030(A) |
| Subdivision EMC 17.12.010 | H | 10 or more EMC 17.16.230(B) | Minimum average lot size 8,400 sq ft EMC 17.16.230(B) |
Minimum lot size 8,400 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 18,000 sq ft EMC 18.06.030(A) Minimum lot width 50 ft EMC 17.16.230(A)(4) Minimum frontage 50 ft EMC 18.06.030(A) |
| Cottage lot EMC 19.46.030; 17.08.010Only for: Dwelling unit cottage, single-family detached (one unit per structure) | A | — | No limit EMC 19.46.030 | Minimum lot size 3,000 sq ft EMC 19.46.050(A)(2)(a) Maximum lot size 8,399 sq ft EMC 19.46.050(A)(2)(e) Minimum lot width 40 ft EMC 19.46.050(A)(2)(c) Maximum units per lot 1 unit EMC 19.46.050(A)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
- All of these are true:
- Conversion of an existing single-family dwelling to a duplex
- New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
- None of these is true:
- New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
- Conversion of an existing single-family dwelling to a duplex
- None of these is true:
- Within a quarter mile of another property that contains permanent supportive housing or transitional housing
- Within a quarter mile of emergency housing or an emergency shelter
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is less than 2
- Lot area is less than 6,200 sf
- Lot area is at least 6,200 sf
- None of these is true:
- The accessory dwelling unit is detached from the principal unit
- The accessory dwelling unit is detached from the principal unit
- All of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- All of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- Not all of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- Within one-half-mile walking distance of a major transit stop
- None of these is true:
- Within one-half-mile walking distance of a major transit stop
- All lots surrounding the parcel to be short platted are substantially greater than the minimum 8,400 square feet