R-3 · R-3 Mixed Residential District
Enumclaw, WA · EMC 18.10 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling unit, single-family detached (one unit per structure) | Home✓ ADU✓ | — | — | — | — |
| Dwelling unit cottage, single-family detached (one unit per structure) | Home✓ ADU✓ | — | — | — | — |
| Dwelling unit, duplex (two units per structure) | — | — | — | — | |
| Cottage housing | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Adult family home protected by state and federal law | — | — | — | — | Home✓ ADU✓ |
| Transitional housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 6,200 sq ft EMC 18.06.030(A); EMC 18.10.040 | 3,000 sq ft EMC 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Minimum lot width | Not set EMC 18.06.030(A) | 40 ft EMC 19.46.050(A)(2)(c)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Minimum frontage | 50 ft EMC 18.06.030(A) | |
| Maximum density | 1 unit per 6,200 sq ft EMC 18.06.030(A) | No limit EMC 19.46.030
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) 1 unit per 3,100 sq ft EMC 18.06.030(B)(3)
|
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft EMC 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Side setback | 9 ft EMC 18.06.030(A) | 5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Rear setback | 25 ft EMC 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum height | 30 ft EMC 18.06.030(A) | Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum stories | Not set EMC 18.06.030(A) | 1 story EMC 19.46.040
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit); Dwelling unit, duplex (two units per structure) (2 units)1 |
| Maximum lot coverage | 40% EMC 18.06.030(A) | |
| Minimum parking | (1.35 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5, rounded down), rounded up spaces EMC 19.40.020(A); 19.40.040(D)(4) | |
| Maximum unit size | Not set EMC 18.06.030(A) | 1,350 sq ft EMC 19.46.040; 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum building floor area | Not set EMC 18.06.030(A) | 2,500 sq ft EMC 18.05.020(B)(3)
for Dwelling unit, duplex (two units per structure) (2 units)1 |
| Maximum lot size | 12,500 sq ft EMC 18.06.030(A) | 6,199 sq ft EMC 19.46.050(A)(2)(e)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units EMC 19.34.020; 19.34.070(B) | |
| Minimum lot size | No limit EMC 19.34.050 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft EMC 19.34.050; 19.34.100(A); 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Side setback | 5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) | |
| Rear setback | ||
| Maximum height | Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft EMC 19.34.070(A) | |
| Attached to the main house | Not required EMC 19.34.070(B) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision EMC 17.08.010 | A | up to 4 EMC 17.04.050 | — | Minimum lot size 6,200 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 12,500 sq ft EMC 18.06.030(A) Minimum frontage 50 ft EMC 18.06.030(A) |
| Subdivision EMC 17.12.010 | H | 5 or more EMC 17.04.050 | — | Minimum lot size 6,200 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 12,500 sq ft EMC 18.06.030(A) Minimum lot width 50 ft EMC 17.16.230(A)(4) Minimum frontage 50 ft EMC 18.06.030(A) |
| Subdivision EMC 17.12.010 | H | 10 or more EMC 17.16.230(B) | Minimum average lot size 6,200 sq ft EMC 17.16.230(B) |
Minimum lot size 6,200 sq ft EMC 18.06.030(A); 17.08.120 Maximum lot size 12,500 sq ft EMC 18.06.030(A) Minimum lot width 50 ft EMC 17.16.230(A)(4) Minimum frontage 50 ft EMC 18.06.030(A) |
| Cottage lot EMC 19.46.030; 17.08.010Only for: Dwelling unit cottage, single-family detached (one unit per structure) | A | — | No limit EMC 19.46.030 | Minimum lot size 3,000 sq ft EMC 19.46.050(A)(2)(a) Maximum lot size 6,199 sq ft EMC 19.46.050(A)(2)(e) Minimum lot width 40 ft EMC 19.46.050(A)(2)(c) Maximum units per lot 1 unit EMC 19.46.050(A)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
- All of these are true:
- Conversion of an existing single-family dwelling to a duplex
- New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
- None of these is true:
- New construction of a one-story duplex with a maximum building size of 2,500 gross square feet including garage
- Conversion of an existing single-family dwelling to a duplex
- None of these is true:
- Within a quarter mile of another property that contains permanent supportive housing or transitional housing
- Within a quarter mile of emergency housing or an emergency shelter
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is less than 2
- None of these is true:
- The accessory dwelling unit is detached from the principal unit
- The accessory dwelling unit is detached from the principal unit
- All of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- All of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- Not all of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- Within one-half-mile walking distance of a major transit stop
- None of these is true:
- Within one-half-mile walking distance of a major transit stop