R-4 · R-4 Multifamily Residential District
Enumclaw, WA · EMC 18.12 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling unit, single-family detached (one unit per structure) | Home✓ ADU✓ | — | — | — | — |
| Dwelling unit cottage, single-family detached (one unit per structure) | Home✓ ADU✓ | — | — | — | — |
| Dwelling unit, live-work | — | ||||
| Dwelling unit, duplex (two units per structure) | — | Home✓ ADU✓ | — | — | — |
| Multifamily development (3+ units per structure) | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Cottage housing | — | — | — | Home✓ ADU✓ | — |
| Adult family home protected by state and federal law | — | — | — | — | Home✓ ADU✓ |
| Transitional housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — | |
| Assisted care living facility, nursing home | — | — | — | — | Home✓ ADU— |
| Retirement homes | — | — | — | — | Home✓ ADU— |
| Co-living housing | — | — | — | — | Home✓ ADU— |
| Group quarters, dormitories, fraternal houses, not including secure community transition facilities or halfway house | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set EMC 18.06.030(A) | 4 units EMC 19.40.110(A)
for Cottage housing (4+ units) |
| Minimum lot size | 6,200 sq ft EMC 18.06.030(A); EMC 18.12.040 | 3,000 sq ft EMC 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Minimum lot width | Not set EMC 18.06.030(A) | 40 ft EMC 19.46.050(A)(2)(c)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Minimum frontage | 50 ft EMC 18.06.030(A) | |
| Maximum density | 1 unit per 2,900 sq ft EMC 18.06.030(A) | No limit EMC 19.46.030
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) 1 unit per the largest of 2,900, lot area ÷ 10 sq ft EMC 18.06.030(A); 18.05.020(B)(7)
1 unit per 1,452 sq ft EMC 18.06.030(B)(4)
for Assisted care living facility, nursing home (group living); Retirement homes (group living) |
| Maximum sleeping units | Not set EMC 18.06.030(A) | 4 × (lot area ÷ 2,900, rounded down) sleeping units EMC 18.06.030(A); 19.32.180(B)(5)
for Co-living housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft EMC 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Side setback | 9 ft EMC 18.06.030(A) | 5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Rear setback | 25 ft EMC 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Building separation | Not set EMC 18.06.030(A) | 10 ft EMC 19.40.110(A)
for Cottage housing (4+ units) |
| Maximum height | 45 ft EMC 18.06.030(A) | Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum stories | 3 stories EMC 18.06.030(A) | 1 story EMC 19.46.040
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit); Cottage housing (4+ units) |
| Maximum lot coverage | 40% EMC 18.06.030(A) | |
| Minimum parking | (1.35 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5, rounded down), rounded up spaces EMC 19.14.070; 19.40.040(D)(4)
for Multifamily development (3+ units per structure) (3, 4+ units); Cottage housing (4+ units) (0.33 × beds in the project) + employees on the largest shift, rounded spaces EMC 19.14.070
for Adult family home protected by state and federal law (group living); Transitional housing (group living)2; Permanent supportive housing (group living)2; Assisted care living facility, nursing home (group living); Group quarters, dormitories, fraternal houses, not including secure community transition facilities or halfway house (group living) 0.75 spaces per unit EMC 19.14.070
for Retirement homes (group living) | |
| Maximum unit size | Not set EMC 18.06.030(A) | 1,350 sq ft EMC 19.46.040; 19.46.050(A)(2)(a)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) 1,200 sq ft EMC 19.40.110(A)
for Cottage housing (4+ units) 600 sq ft EMC 19.32.180(B)(1)
for Co-living housing (group living) |
| Maximum lot size | Not set EMC 18.06.030(A) | 6,199 sq ft EMC 19.46.050(A)(2)(e)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Maximum building footprint | Not set EMC 18.06.030(A) | 800 sq ft EMC 19.40.110(A)
for Cottage housing (4+ units) |
| Minimum open space | Not set EMC 18.06.030(A) | Developments other than townhouses, duplexes, and cottages shall provide open space (designed per subsection D of this section) equivalent to 20 percent of the building's livable floor area (excludes hallways and common areas). EMC 19.40.050(C)
for Multifamily development (3+ units per structure) (3, 4+ units) Open space shall be provided at a minimum of 10 square feet for each 100 square feet of sleeping unit space. EMC 19.32.180(B)(3)
for Co-living housing (group living) |
| Maximum units per building | Not set EMC 18.06.030(A) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units EMC 19.34.020; 19.34.070(B) | |
| Minimum lot size | No limit EMC 19.34.050 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft EMC 19.34.050; 19.34.100(A); 18.06.030(A) | 15 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) |
| Side setback | 5 ft EMC 19.46.050(A)(2)(b)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) | |
| Rear setback | ||
| Maximum height | Maximum height for all structures: one story or 18 feet; whichever is taller. EMC 19.46.050(A)(2)(d)
for Dwelling unit cottage, single-family detached (one unit per structure) (1 unit) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft EMC 19.34.070(A) | |
| Attached to the main house | Not required EMC 19.34.070(B) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision EMC 17.08.010 | A | up to 4 EMC 17.04.050 | — | Minimum lot size 6,200 sq ft EMC 18.06.030(A); 17.08.120 Minimum frontage 50 ft EMC 18.06.030(A) |
| Subdivision EMC 17.12.010 | H | 5 or more EMC 17.04.050 | — | Minimum lot size 6,200 sq ft EMC 18.06.030(A); 17.08.120 Minimum lot width 50 ft EMC 17.16.230(A)(4) Minimum frontage 50 ft EMC 18.06.030(A) |
| Subdivision EMC 17.12.010 | H | 10 or more EMC 17.16.230(B) | Minimum average lot size 6,200 sq ft EMC 17.16.230(B) |
Minimum lot size 6,200 sq ft EMC 18.06.030(A); 17.08.120 Minimum lot width 50 ft EMC 17.16.230(A)(4) Minimum frontage 50 ft EMC 18.06.030(A) |
| Zero lot line development EMC 18.06.130(C)(6); 17.08.010Only for: Dwelling unit, single-family detached (one unit per structure) | A | — | Maximum units Not set EMC 18.06.130 |
Minimum lot size 3,000 sq ft EMC 18.06.130(C) Maximum units per lot 1 unit EMC 18.06.130(C)(2) |
| Zero lot line development EMC 18.06.130(C)(6); 17.08.010Only for: Dwelling unit, duplex (two units per structure) | A | — | Maximum units Not set EMC 18.06.130 |
Minimum lot size 3,000 sq ft EMC 18.06.130(C) Maximum units per lot 1 unit EMC 18.06.130(C)(2) |
| Zero lot line development EMC 18.06.130(C)(6); 17.08.010Only for: Cottage housing | A | — | Maximum units Not set EMC 18.06.130 |
Minimum lot size 2,500 sq ft EMC 18.06.130(C) Maximum units per lot 1 unit EMC 18.06.130(C)(2) |
| Zero lot line development EMC 18.06.130(C)(6); 17.08.010Only for: Multifamily development (3+ units per structure) | A | — | Maximum units Not set EMC 18.06.130 |
Minimum lot size 1,600 sq ft EMC 18.06.130(C) Maximum units per lot 1 unit EMC 18.06.130(C)(2) |
| Cottage lot EMC 19.46.030; 17.08.010Only for: Dwelling unit cottage, single-family detached (one unit per structure) | A | — | No limit EMC 19.46.030 | Minimum lot size 3,000 sq ft EMC 19.46.050(A)(2)(a) Maximum lot size 6,199 sq ft EMC 19.46.050(A)(2)(e) Minimum lot width 40 ft EMC 19.46.050(A)(2)(c) Maximum units per lot 1 unit EMC 19.46.050(A)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Allowed as part of a live-work project; the work space is an accessory use
- None of these is true:
- Within a quarter mile of another property that contains permanent supportive housing or transitional housing
- Within a quarter mile of emergency housing or an emergency shelter
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is less than 2
- Within one-half-mile walking distance of a major transit stop
- None of these is true:
- Within one-half-mile walking distance of a major transit stop
- Units are built as attached townhouse dwellings
- None of these is true:
- Units are built as attached townhouse dwellings
- None of these is true:
- The accessory dwelling unit is detached from the principal unit
- The accessory dwelling unit is detached from the principal unit
- All of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- All of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- Not all of these are true:
- The accessory dwelling unit is detached from the principal unit
- The rear lot line abuts an alley
- None of these is true:
- Corner lot
- Corner lot