CC · City center core (CC-C)
Federal Way, WA · FWRC 19.225 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Permanent supportive housing and transitional housing | — | ||||
| Multifamily dwelling units (stacked dwelling units) | — | — | |||
| Senior citizen housing | — | — | |||
| Special needs housing | — | — | |||
| Co-living housing | — | — | — | — | HomeA ADU— |
| Emergency housing and shelter | — | — | — | — | |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Convalescent center or nursing home | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set FWRC 19.225.070 | 200 units FWRC 19.225.075 note 2
for Permanent supportive housing and transitional housing (4+ units)2 |
| Minimum lot size | No limit FWRC 19.225.075 | Not set FWRC 19.225.065
for Co-living housing (group living); Emergency housing and shelter (group living)3; Convalescent center or nursing home (group living) |
| Minimum density | 46 units per acre FWRC 19.225.075 | Not set FWRC 19.225.065
for Co-living housing (group living); Convalescent center or nursing home (group living) |
| Maximum density | 230 units per acre, on the net lot area FWRC 19.225.075 | Not set FWRC 19.225.065
for Co-living housing (group living); Convalescent center or nursing home (group living) |
| Maximum residents | Not set FWRC 19.225.065 | The city will determine the maximum number of residents and the number of dwelling units or occupancy rooms or suites permitted in a stand-alone development FWRC 19.225.055 note 3
for Emergency housing and shelter (group living)3 6 persons FWRC 19.05.010
for Adult family home (group living) |
| Maximum sleeping units | Not set FWRC 19.225.055 | (920 × lot area minus critical areas and buffers) ÷ 43,560, rounded down sleeping units FWRC 19.225.065
for Co-living housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft FWRC 19.225.075 | 20 ft FWRC 19.225.055
for Emergency housing and shelter (group living)3; Convalescent center or nursing home (group living) |
| Maximum front setback | Not set FWRC 19.225.075
10 ft FWRC 19.225.010 note 1
for Multifamily dwelling units (stacked dwelling units) (2, 3, 4+ units)1; Adult family home (group living) | |
| Side setback | 0 ft FWRC 19.225.075 | |
| Rear setback | 0 ft FWRC 19.225.075 | |
| Maximum height | Building height must be consistent with the minimum density of 46 units per acre of developable site area and maximum density of 230 units per acre of developable site area. FWRC 19.225.075 | Building height must be consistent with the minimum density of 184 sleeping units per acre of developable site area and maximum density of 920 sleeping units per acre of developable site area. FWRC 19.225.065
for Co-living housing (group living) Building height must be consistent with the minimum FAR of 1.5 and the maximum FAR of 10.0. FWRC 19.225.080 note 6
for Convalescent center or nursing home (group living) |
| Maximum lot coverage | Not set FWRC 19.225.070 | |
| Maximum floor area ratio | Not set FWRC 19.225.075 | 10 FWRC 19.225.080 note 6
for Convalescent center or nursing home (group living) |
| Minimum parking | 0 spaces per unit FWRC 19.225.070
for Senior citizen housing (2, 3, 4+ units)1 for Co-living housing (group living) (beds in the project ÷ 3) + (employees on the largest shift ÷ 2) spaces FWRC 19.225.080
for Convalescent center or nursing home (group living) | |
| Minimum open space | The subject property must provide usable open space in a total amount equal to at least 100 sq. ft. per dwelling unit. Developments of five or fewer units are exempt from this usable open space requirement. FWRC 19.225.075 note 11 | The subject property must provide usable open space in a total amount equal to at least 25 sq. ft. per sleeping unit. Developments of five or fewer sleeping units are exempt from this usable open space requirement. FWRC 19.225.065 note 6
for Co-living housing (group living) Not set FWRC 19.225.055
for Emergency housing and shelter (group living)3; Convalescent center or nursing home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Binding site plan FWRC 18.20.050 | A | — | — | Minimum lot size Not set FWRC 18.20.010 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- At least 15 percent of the ground floor is nonresidential use
- All of these are true:
- Any of these is true:
- None of these is true:
- Lot is within 5,400 ft of a property with more than three units of permanent supportive housing and/or transitional housing
- Main dwelling units on the lot is at most 2
- None of these is true:
- At least 15 percent of the ground floor is nonresidential use
- Any of these is true:
- All of these are true:
- At least 15 percent of the ground floor is nonresidential use
- Lot is within 1,000 ft of any other emergency housing and shelter
- Lot is in the downtown architectural overlay (FWRC 19.245.020)
- Lot is within 1,000 ft of a public school
- All of these are true:
- The building is stand-alone housing (no ground floor commercial use with it)
- The project provides publicly visible streetscape amenities along the right-of-way to get 85 ft height
- All of these are true:
- The building is stand-alone housing (no ground floor commercial use with it)
- The project provides publicly visible streetscape amenities along the right-of-way to get 85 ft height
- None of these is true:
- The building is stand-alone housing (no ground floor commercial use with it)
- The building is stand-alone housing (no ground floor commercial use with it)
- The property line is adjacent to a residential zone
- None of these is true:
- The property line is adjacent to a residential zone
- Floor area of one unit is less than 1,200
- Floor area of one unit is at least 1,200
- Lot is within 1/2 mile walking distance of a major transit stop
- None of these is true:
- Lot is within 1/2 mile walking distance of a major transit stop