HIGH DENSITY RESIDENTIAL · High Density Residential (HDR) District
Fife, WA · FMC 19.28 · Official code
By right: 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Courtyard apartments | — | — | |||
| Stacked flats | — | — | — | ||
| Townhouses | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Triplex dwelling | — | — | Home✓ ADU✓ | — | — |
| Multifamily structure | — | — | — | — | |
| General group home | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Co-living housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 6 units FMC 19.28.020(D) | Not set FMC 19.28.020(H)
for Multifamily structure (4+ units)3 |
| Minimum units | Not set FMC 19.28.020(E) | 4 units FMC 19.28.020(D)
for Multifamily structure (4+ units) 7 units FMC 19.28.020(H)
for Multifamily structure (4+ units)3 |
| Minimum lot size | 2,500 sq ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Minimum frontage | ||
| Maximum density | 25 units per acre, a fraction of 0.5 or more rounds up FMC 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Minimum development size | 130,680 sq ft FMC 19.52.040(A)
for Multifamily structure (4+ units)3 | |
| Maximum sleeping units | Not set FMC 19.28.020(I) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 8 ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Side setback | 0 ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Street side setback | 8 ft FMC 19.68.040(A)(1)(a); 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Rear setback | 0 ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Building separation | ||
| Maximum height | 30 ft FMC 19.51.010 | 35 ft FMC 19.51.010
for Multifamily structure (4+ units); Multifamily structure (4+ units)3; Co-living housing (group living) |
| Maximum stories | 2 stories FMC 19.51.010 | 3 stories FMC 19.51.010
for Multifamily structure (4+ units); Multifamily structure (4+ units)3; Co-living housing (group living) |
| Maximum lot coverage | 65% FMC 19.52.030(H)
for Multifamily structure (4+ units)3 | |
| Minimum parking | For uses not specifically identified in this chapter, the amount of parking required shall be based on the requirements for similar uses as determined by the director. FMC 19.56.040(J)
for General group home (group living) The same requirement as the housing type which the unit is in plus 1 stall for each on-site employee, as applicable. FMC 19.56.040(B)
for Transitional housing (group living); Permanent supportive housing (group living) | |
| Maximum unit size | Not set FMC 19.51.010 | 300 sq ft FMC 19.68.063(C)(1)(a)
for Co-living housing (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit FMC 19.80.030(A) | |
| Minimum lot size | Not set FMC 19.80.030(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 24 ft FMC 19.80.040(A)(1) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft FMC 19.80.030(C) | |
| Attached to the main house | Not set FMC 19.80.030(A) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision FMC 18.06.010(A)(1); 18.06.040(C)(2) | A | up to 9 FMC 18.03.200; 18.06.020 | — | Minimum lot size 3,000 sq ft FMC 19.68.020(A)(1)(a); 19.51.010 |
| Subdivision FMC 18.06.010(A)(1); 18.06.040(C)(3) | H | 10 or more FMC 18.03.220; 18.06.020 | — | Minimum lot size 3,000 sq ft FMC 19.68.020(A)(1)(a); 19.51.010 |
| Unit lot subdivision FMC 18.06.010(A)(1); 18.06.040(C)(2)Only for: Triplex dwelling, Courtyard apartments, Townhouses | A20 | up to 9 FMC 18.06.020 | — | Minimum lot size Not set FMC 18.06.055(B)(1) |
| Large lot division FMC 18.08.070(B) | A | 2 or more FMC 18.03.110 | — | Minimum lot size 217,800 sq ft FMC 18.03.110; 18.08.070(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot area is at least 3,000 sf
- Lot area is less than 3,000 sf
- Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
- None of these is true:
- Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
- None of these is true:
- Lot has an alley or an easement serving 2 lots or less as its sole access
- Lot has an alley or an easement serving 2 lots or less as its sole access
- Building stories is at most 2
- Building stories is at least 3
- Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
- All of these are true:
- Lot area is less than 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
- All of these are true:
- Lot area is at least 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
- Bedrooms in one unit is 0
- Bedrooms in one unit is 1
- Bedrooms in one unit is at least 2
- None of these is true:
- Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
- All of these are true:
- Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
- Lot area is at least 3,000 sf
- Lot is within one-quarter mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-quarter mile walking distance of a major transit stop
- All of these are true:
- Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
- Lot area is less than 3,000 sf
- No dwelling unit is stacked on another separate dwelling unit