MR · Multiple residential (MR) zone
Granite Falls, WA · GFMC 19.03.080 · Official code
By right: 1 unit, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, single-family | Home✓ ADU— | — | — | — | — |
| Manufactured home | — | — | — | — | |
| Live/work units | HomeA ADU— | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Triplex | — | — | Home✓ ADU— | — | — |
| Dwelling, multiple-family | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Townhouse | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Courtyard apartments | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Mobile home park | — | — | — | — | |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Assisted senior living facility | — | — | — | — | Home✓ ADU— |
| Boarding house | — | — | — | — | Home✓ ADU— |
| Foster home | — | — | — | — | Home✓ ADU— |
| Nursing or convalescent home | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set GFMC 19.03.080 | 6 units GFMC 19.06.120(C)(1)
for Mobile home park (4+ units)2 |
| Minimum lot size | 6,000 sq ft GFMC 19.03.080(B) | Not set GFMC 19.06.120(G)
for Mobile home park (4+ units)2 |
| Minimum lot width | Not set GFMC 19.06.120(G)
for Mobile home park (4+ units)2 | |
| Minimum lot depth | Each lot should have an average depth between the front and rear lot lines of not less than one foot depth for each one foot of width. GFMC 19.04D.040(F) | |
| Minimum density | 12 units per acre GFMC 19.03.080(H) | Not set GFMC 19.03.080
for Adult family home (group living); Assisted senior living facility (group living); Boarding house (group living); Foster home (group living); Nursing or convalescent home (group living); Permanent supportive housing (group living); Transitional housing (group living) |
| Maximum density | Not set GFMC 19.03.080
for Adult family home (group living); Assisted senior living facility (group living); Boarding house (group living); Foster home (group living); Nursing or convalescent home (group living); Permanent supportive housing (group living); Transitional housing (group living) | |
| Minimum development size | Not set GFMC 19.03.080 | 87,120 sq ft GFMC 19.06.120(G)(2); 19.06.120(C)(1)
for Mobile home park (4+ units)2 |
| Maximum residents | Not set GFMC 19.03.080 | 6 persons GFMC 19.02.010
for Adult family home (group living) 3 persons GFMC 19.02.060
for Foster home (group living) |
| Maximum sleeping units | Not set GFMC 19.03.080 | 5 sleeping units GFMC 19.02.020
for Boarding house (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft GFMC 19.03.080(D)(1) | 20 ft GFMC 19.06.120(G)(8)(b)
for Mobile home park (4+ units)2 |
| Side setback | 5 ft GFMC 19.03.080(D)(2) | for Triplex (3 units); Dwelling, multiple-family (3, 4+ units); Courtyard apartments (3, 4+ units) 20 ft GFMC 19.06.120(G)(8)(a)
for Mobile home park (4+ units)2 |
| Street side setback | 10 ft GFMC 19.03.080(D)(2); 19.03.080(D)(1) | 20 ft GFMC 19.06.120(G)(8)(b)
for Mobile home park (4+ units)2 |
| Rear setback | 20 ft GFMC 19.03.080(D)(3) | |
| Building separation | Not set GFMC 19.03.080 | 10 ft GFMC 19.06.120(G)(8)(d)
for Mobile home park (4+ units)2 |
| Maximum height | 33 ft GFMC 19.03.080(E) | |
| Maximum lot coverage | 70% GFMC 19.03.080(F) | |
| Maximum impervious surface | 70% GFMC 19.03.080(F) | |
| Minimum parking | 0.5 spaces per bed GFMC 19.06.050(A)(9)
for Adult family home (group living) In the case of a use not specifically mentioned in subsection (A)(9) of this section, the requirements for off-street parking facilities shall be determined by the designated official. GFMC 19.06.050(A)(8)
for Assisted senior living facility (group living); Nursing or convalescent home (group living); Permanent supportive housing (group living); Transitional housing (group living) 0.25 spaces per sleeping unit GFMC 19.06.050(A)(9)
for Boarding house (group living) 2 spaces per unit GFMC 19.06.050(A)(9); 19.06.100
for Foster home (group living) | |
| Minimum open space | Not set GFMC 19.03.080 | 15% GFMC 19.06.120(G)(13)(a)
for Mobile home park (4+ units)2 |
| Maximum units per building | Not set GFMC 19.03.080 | 6 units GFMC 19.02.200
for Townhouse (3, 4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short GFMC 19.04A.210(D) | A | up to 9 GFMC 19.05.005 | 24 units per acre, a fraction of 0.5 or more rounds up, on the net lot area GFMC 19.03.080(G); 19.06.015(A) Minimum density 12 units per acre GFMC 19.03.080(H); 19.06.015(A) |
Minimum lot size 6,000 sq ft GFMC 19.03.080(B); 19.04D.040(E) Minimum lot depth Each lot should have an average depth between the front and rear lot lines of not less than one foot depth for each one foot of width. GFMC 19.04D.040(F) Minimum frontage Not set GFMC 19.04D.040(E) |
| Subdivision GFMC 19.04A.210(D) | H | 10 or more GFMC 19.05.005 | 24 units per acre, a fraction of 0.5 or more rounds up, on the net lot area GFMC 19.03.080(G); 19.06.015(A) Minimum density 12 units per acre GFMC 19.03.080(H); 19.06.015(A) |
Minimum lot size 6,000 sq ft GFMC 19.03.080(B); 19.04D.040(E) Minimum lot depth Each lot should have an average depth between the front and rear lot lines of not less than one foot depth for each one foot of width. GFMC 19.04D.040(F) Minimum frontage Not set GFMC 19.04D.040(E) |
| Unit lot subdivision GFMC 19.05.310(E); 19.04A.210(D) | A | up to 9 GFMC 19.05.310(E) | 24 units per acre, a fraction of 0.5 or more rounds up, on the net lot area GFMC 19.03.080(G); 19.06.015(A) Minimum density 12 units per acre GFMC 19.03.080(H); 19.06.015(A) |
Minimum lot size Administrative deviation from setback, lot width, hard surface coverage, and lot area standards in Chapter 19.03 GFMC may be approved for individual unit lots through a unit lot subdivision, subject to any limitations in this section. GFMC 19.05.310(B) Minimum lot width Administrative deviation from setback, lot width, hard surface coverage, and lot area standards in Chapter 19.03 GFMC may be approved for individual unit lots through a unit lot subdivision, subject to any limitations in this section. GFMC 19.05.310(B) Maximum units per lot Not set GFMC 19.05.310 |
| Unit lot subdivision GFMC 19.05.310(E); 19.04A.210(D) | H | 10 or more GFMC 19.05.310(E) | 24 units per acre, a fraction of 0.5 or more rounds up, on the net lot area GFMC 19.03.080(G); 19.06.015(A) Minimum density 12 units per acre GFMC 19.03.080(H); 19.06.015(A) |
Minimum lot size Administrative deviation from setback, lot width, hard surface coverage, and lot area standards in Chapter 19.03 GFMC may be approved for individual unit lots through a unit lot subdivision, subject to any limitations in this section. GFMC 19.05.310(B) Minimum lot width Administrative deviation from setback, lot width, hard surface coverage, and lot area standards in Chapter 19.03 GFMC may be approved for individual unit lots through a unit lot subdivision, subject to any limitations in this section. GFMC 19.05.310(B) Maximum units per lot Not set GFMC 19.05.310 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The manufactured home has at least two fully enclosed parallel sections, each not less than 12 feet wide by 36 feet long
- None of these is true:
- The site is in a floodplain area or shoreline zone
- The lot is a corner lot (frontage on two or more streets where the streets meet)
- None of these is true:
- The lot is a corner lot (frontage on two or more streets where the streets meet)
- None of these is true:
- The dwelling units are created entirely within an existing building, in a residential, commercial or mixed-use zone where residential uses are allowed
- The dwelling units are created entirely within an existing building, in a residential, commercial or mixed-use zone where residential uses are allowed
- The lot line is adjacent to property designated single-family by the Granite Falls comprehensive plan
- None of these is true:
- The lot line is adjacent to property designated single-family by the Granite Falls comprehensive plan
- The units have a common wall in a zero lot line development (on that side)
- None of these is true:
- The units have a common wall in a zero lot line development (on that side)