A-10 · Agricultural District
Kent, WA · KCC 15.03.010; 15.04.020; 15.04.170 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached or single-family dwelling | Home✓ ADUA | — | — | — | — |
| One modular home per lot | Home✓ ADUA | — | — | — | — |
| Designated manufactured home | — | — | — | — | |
| Permanent supportive housing | Home✓ ADUA | Home✓ ADUA | Home✓ ADUA | Home✓ ADUA | — |
| Farm worker accommodations | — | — | — | — | |
| Group homes class I | — | — | — | — | |
| Communal residences tier 1 | — | — | — | — | |
| Communal residences tier 2 | — | — | — | — | |
| Transitional housing | — | — | — | — | Home✓ ADUA |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 435,600 sq ft KCC 15.04.170 | |
| Minimum lot width | 60 ft KCC 15.04.170; 15.04.180(4) | |
| Maximum density | 0.1 units per acre, ADUs included KCC 15.04.170; 15.04.180(27)(a) | |
| Maximum residents | Not set KCC 15.04.170 | |
| Maximum sleeping units | Not set KCC 15.04.170 | 3 sleeping units KCC 15.04.030(33)(a)(iii)
for Communal residences tier 1 (group living)4 4 × ((0.1 × lot area) ÷ 43,560, rounded down) sleeping units KCC 15.04.170; 15.04.030(33)(b)(iii)
for Communal residences tier 2 (group living)5 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft KCC 15.04.170; 15.04.180(6) | |
| Side setback | 15 ft KCC 15.04.170 | |
| Street side setback | 20 ft KCC 15.04.170 | |
| Rear setback | 20 ft KCC 15.04.170 | |
| Building separation | Building code KCC 15.04.170 | |
| Maximum height | 35 ft KCC 15.04.170 | |
| Maximum stories | 2.5 stories KCC 15.04.170 | |
| Maximum lot coverage | 30% KCC 15.04.170 | |
| Maximum impervious surface | ||
| Minimum parking | 2 spaces per unit KCC 15.05.040(A) | For uses not specifically identified in this section, the amount of parking required shall be determined by the planning department, based on staff experience, parking required for similar uses, and, if appropriate, documentation provided by the applicant. KCC 15.05.040(A)
for Permanent supportive housing (1, 2, 3, 4+ units); Transitional housing (group living) for Communal residences tier 1 (group living)4 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units KCC 15.08.350(B)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft KCC 15.04.170; 15.04.180(6) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum stories | 2.5 stories KCC 15.08.350(B)(8); 15.04.170 | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft KCC 15.08.350(B)(6) | |
| Attached to the main house | Not required KCC 15.08.350(B)(2)(a)-(c) | |
| Owner lives on site | Not required KCC 15.08.350(B)(9) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 12.01.040(A); 12.04.185 | A | up to 9 KCC 12.04.025(MM); 12.04.105(A) | — | Minimum lot size 435,600 sq ft KCC 15.04.170 Minimum lot width 60 ft KCC 15.04.170; 15.04.180(4) |
| Subdivision KCC 12.01.040(A); 12.04.177; 12.04.192 | H | 10 or more KCC 12.04.025(OO); 12.04.107(A) | — | Minimum lot size 435,600 sq ft KCC 15.04.170 Minimum lot width 60 ft KCC 15.04.170; 15.04.180(4) |
| Unit lot subdivision KCC 12.04.260(A); 12.01.040(A) | A | up to 9 KCC 12.04.260(A); 12.04.025(TT); 12.04.025(MM) | — | Minimum lot size A unit lot may be as small as the footprint of the dwelling unit it contains, provided it meets applicable requirements KCC 12.04.260(D)(3) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The designated manufactured home is a new manufactured home
- The accommodation houses farm operators or employees of a farm operation on the lot, not transient labor
- The ADU is used as part of the operation of the group home and is not leased or subleased to a separate family
- All of these are true:
- Lot area is less than 2,613,600 sf
- The tier 1 communal residence is within a single-family dwelling unit or an accessory dwelling unit
- Lot area is at least 2,613,600 sf
- The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
- None of these is true:
- The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
- Any of these is true:
- The lot is used for agricultural practices
- Lot area is at most 43,560 sf
- All of these are true:
- Lot area is more than 43,560 sf
- The lot is used for agricultural practices
- Lot is within one-half-mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-half-mile walking distance of a major transit stop
- All of these are true:
- The ADU is detached
- The detached ADU is located in the rear one-half of the lot
- Not all of these are true:
- The ADU is detached
- The detached ADU is located in the rear one-half of the lot
- The ADU is detached
- None of these is true:
- The ADU is detached