DC · Downtown Commercial District
Kent, WA · KCC 15.03.010; 15.04.020; 15.04.190 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Permanent supportive housing | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Multifamily dwellings | — | — | — | — | |
| Group homes class I | — | — | — | — | Home✓ ADU— |
| Group homes class II-A | — | — | — | — | |
| Group homes class II-B | — | — | — | — | |
| Group homes class II-C | — | — | — | — | |
| Group homes class III | — | — | — | — | |
| Communal residences tier 2 | — | — | — | — | |
| Transitional housing | — | — | — | — | |
| Emergency housing facility; indoor emergency shelter | — | — | — | — | |
| Outside emergency shelter | — | — | — | — | |
| Independent senior living facilities | — | — | — | — | |
| Assisted living facilities | — | — | — | — | |
| Residential facilities with health care | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | 7 units KCC 15.02.125 | Not set KCC 15.04.020
for Permanent supportive housing (4+ units) |
| Minimum lot size | for Multifamily dwellings (4+ units)1 43,560 sq ft KCC 15.04.030(35)(a)(ii)
for Emergency housing facility; indoor emergency shelter (group living)5 87,120 sq ft KCC 15.04.030(31)(b)(ii)
for Outside emergency shelter (group living)6 | |
| Maximum residents | Not set KCC 15.04.190 | 8 persons KCC 15.02.173(B)(1)
for Group homes class II-A (group living)2 12 persons KCC 15.02.173(B)(2)
for Group homes class II-B (group living)2 18 persons KCC 15.02.173(B)(3)
for Group homes class II-C (group living)2 35 persons KCC 15.04.030(31)(b)(i)
for Outside emergency shelter (group living)6 |
| Maximum sleeping units | Not set KCC 15.04.190 | In zones without a dwelling unit density limit, the maximum number of sleeping units shall be determined by building bulk, height, lot coverage, and applicable building code standards. KCC 15.04.030(33)(b)(iii)
for Communal residences tier 2 (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | None, except as required by landscaping, or if off-street parking is provided onsite. KCC 15.04.195(2) | 20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(2)
for Outside emergency shelter (group living)6 |
| Side setback | None, except as required by landscaping, or if off-street parking is provided onsite. KCC 15.04.195(2) | 15 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(3)
for Outside emergency shelter (group living)6 |
| Rear setback | None, except as required by landscaping, or if off-street parking is provided onsite. KCC 15.04.195(2) | 20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(4)
for Outside emergency shelter (group living)6 |
| Maximum height | 60 ft KCC 15.04.190 | |
| Maximum stories | 4 stories KCC 15.04.190 | |
| Maximum lot coverage | 100% KCC 15.04.190 | |
| Minimum parking | 0 spaces per bed KCC 15.05.070(A) | 0 spaces per unit KCC 15.05.070(A)
for Permanent supportive housing (1, 2, 3, 4+ units) 1 space per unit KCC 15.05.070(A)
for Multifamily dwellings (4+ units)1 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 12.01.040(A); 12.04.185 | A | up to 9 KCC 12.04.025(MM); 12.04.105(A) | — | |
| Subdivision KCC 12.01.040(A); 12.04.177; 12.04.192 | H | 10 or more KCC 12.04.025(OO); 12.04.107(A) | — | |
| Unit lot subdivision KCC 12.04.260(A); 12.01.040(A) | A | up to 9 KCC 12.04.260(A); 12.04.025(TT); 12.04.025(MM) | — | Minimum lot size A unit lot may be as small as the footprint of the dwelling unit it contains, provided it meets applicable requirements KCC 12.04.260(D)(3) |
| Planned unit development KCC 15.08.400(A); 12.04.050; 12.01.040(A) | H | Maximum lots Not set KCC 15.08.400 |
— | Minimum lot size No limit KCC 15.08.400(C)(1) |
| Binding site plan KCC 12.04.805(B); 12.01.040(A) | A | Maximum lots Not set KCC 12.04.800 |
— | Minimum lot size Not set KCC 12.04.800 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The residential use is in a building with commercial or office uses
- Residential use is placed on the ground floor
- None of these is true:
- Another approved group home is located within 1,000 feet of the proposed class II or III group home
- A public school is within 1,000 feet of the proposed class II or III group home
- Another class II or III group home is within 600 feet
- A school, church or religious facility, park, playground or other sensitive use is within 1,000 feet
- None of these is true:
- Another approved group home is located within 1,000 feet of the proposed class II or III group home
- A public school is within 1,000 feet of the proposed class II or III group home
- Another class II or III group home is within 600 feet
- A school, church or religious facility, park, playground or other sensitive use is within 1,000 feet
- A residential area is within 1,000 feet
- None of these is true:
- The residential use is in a building with commercial or office uses
- None of these is true:
- Another approved emergency housing, indoor emergency shelter, or outside emergency shelter facility is within 1,000 feet
- All of these are true:
- An actively operating religious organization is on the same lot
- Another approved emergency housing, indoor emergency shelter, or outside emergency shelter facility is within 1,000 feet
- The lot is an existing lot of record
- None of these is true:
- The lot is an existing lot of record
- Lot is in the Kent downtown planning area identified in KCC 15.09.046
- All of these are true:
- The lot is an existing lot of record
- Lot is in the Kent downtown planning area identified in KCC 15.09.046
- None of these is true:
- Lot is in the Kent downtown planning area identified in KCC 15.09.046
- The lot is an existing lot of record
- The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
- None of these is true:
- The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066