NRH 6 · North Rose Hill Business District 6

Kirkland, WA · KZC 54 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Dwelling Unit
Home✓ ADU✓
————
Detached, Attached, or Stacked Dwelling Units—
HomeA ADU—
HomeA ADU—
HomeA1 ADU—
—
Assisted Living Facility————
HomeA ADU—
Co-Living Housing————
HomeA2 ADU—
Nursing Home————
HomeA ADU—
Convalescent Center————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units(lot area ÷ 1,800, rounded down) + (2 × units that are income-restricted affordable housing) units KZC 54.42.010; 54.40(2)
Minimum lot size3,600 sq ft KZC 54.42.010
No limit KZC 54.42.070
for Assisted Living Facility (group living)
Not set KZC 54.42.080
for Nursing Home (group living); Convalescent Center (group living)
Maximum densityNot set KZC 54.42.010
1 unit per 1,800 sq ft KZC 54.42.010
for Detached Dwelling Unit (1 unit); Detached, Attached, or Stacked Dwelling Units (2, 3 units)
Maximum sleeping unitsNot set KZC 54.42.080
2 × (lot area ÷ 1,800, rounded down) sleeping units KZC 54.42.070; 54.42.010
for Assisted Living Facility (group living)
4 × (lot area ÷ 1,800, rounded down) sleeping units KZC 54.42.010; 111.25(1)
for Co-Living Housing (group living)2

3. Building standards

StandardValueExceptions
Front setback10 ft KZC 54.42.010
Side setback5 ft KZC 54.42.010
Total side setbacks15 ft KZC 54.42.010
Not set KZC 54.42.010
for Detached Dwelling Unit (1 unit)
Rear setback10 ft KZC 54.42.010
Maximum height30 ft KZC 54.42.010
Maximum lot coverage70% KZC 54.42.010
Minimum parking
  • 0 spaces per unit3 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit4 KZC 105.22(2)(a)(2)
  • 0 spaces per unit3 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 1 space per unit4 KZC 105.22(2)(a)(1)
for Detached Dwelling Unit (1 unit)
0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living)
  • 0 spaces per unit5 KZC 111.25(2)(a); 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit6 KZC 105.22(2)(a)(2)
for Co-Living Housing (group living)2
0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living)
1 space per bed KZC 54.42.080
for Convalescent Center (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units KZC 115.07

Building

StandardValueExceptions
Front setback10 ft KZC 54.42.010; KZC 115.07(5)
Side setback5 ft KZC 54.42.010; KZC 115.07(5)
Rear setback10 ft KZC 54.42.010; KZC 115.07(5)
Maximum height30 ft KZC 54.42.010; KZC 115.07(5)
Minimum parking0 spaces per unit KZC 105.22(1)(b)(2)
Maximum unit size1,200 sq ft KZC 115.07(4)
Attached to the main houseNot required KZC 115.07(5)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Planned Unit Development KZC 125.10 H — Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1)
Minimum lot size
Not set KZC 125.25; 125.30

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. At least 10 percent of the units in the development are affordable housing units
  2. Lot could develop six or more units under the base zone
  3. Any of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  4. None of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  5. Any of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit
  6. None of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit