PLA 15B · PLA 15B planned area
Kirkland, WA · KZC 20 · Official code
By right: 1 unit · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached Dwelling Unit | Home✓ ADU✓ | — | — | — | — |
| Detached, Attached, or Stacked Dwelling Units | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Middle Housing | — | — | |||
| Co-Living Housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set KZC 20.30.060 | |
| Minimum units | Not set KZC 20.30.060 | No limit KZC 113.25
for Middle Housing (4+ units)1 |
| Minimum lot size | 5 × 43,560 sq ft KZC 20.30.060 | 12,500 sq ft KZC 20.30.070
for Detached Dwelling Unit (1 unit) No limit KZC 113.25
for Middle Housing (2, 3, 4+ units)1 |
| Minimum density | Not set KZC 20.30.070 | Medium and high-density zones have a minimum density that is 80 percent of the maximum allowed density. Middle housing projects must provide no fewer than the minimum number of units established by the base zoning before this chapter’s density calculations are applied. KZC 113.25
for Middle Housing (2, 3, 4+ units)1 |
| Maximum density | 1 unit per 6,200 sq ft KZC 20.30.060 | Not set KZC 20.30.070
A development more than a quarter-mile walking distance of a major transit stop may have the greater of: Four units per lot; or Twice the maximum number of Detached Dwelling Units allowed in the residential zones. KZC 113.25
for Middle Housing (2, 3, 4+ units)1 |
| Maximum sleeping units | 4 × (lot area ÷ 6,200, rounded down) sleeping units KZC 20.30.060; 111.25(1) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft KZC 20.30.070 | The City will determine required yards and structure height based on the compatibility of development with adjacent uses and the degree to which development maintains the existing natural characteristics of the slope. KZC 20.30 DD-20
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units); Co-Living Housing (group living)2 |
| Side setback | 5 ft KZC 20.30.070 | The City will determine required yards and structure height based on the compatibility of development with adjacent uses and the degree to which development maintains the existing natural characteristics of the slope. KZC 20.30 DD-20
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units); Co-Living Housing (group living)2 |
| Street side setback | Not set KZC 20.30.070 | 5 ft KZC 113.25
for Middle Housing (2, 3, 4+ units)1 |
| Rear setback | 10 ft KZC 20.30.070 | The City will determine required yards and structure height based on the compatibility of development with adjacent uses and the degree to which development maintains the existing natural characteristics of the slope. KZC 20.30 DD-20
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units); Co-Living Housing (group living)2 |
| Maximum height | 25 ft KZC 20.30.070 | The City will determine required yards and structure height based on the compatibility of development with adjacent uses and the degree to which development maintains the existing natural characteristics of the slope. KZC 20.30 DD-20
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units); Co-Living Housing (group living)2 |
| Maximum lot coverage | 50% KZC 20.30.070 | |
| Minimum parking | for Detached Dwelling Unit (1 unit) | |
| Maximum unit size | Not set KZC 20.30.070 | 800 square feet for Carriage Units, 1,700 square feet for Cottage units KZC 113.25
for Middle Housing (2, 3, 4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units KZC 115.07 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft KZC 20.30.070; KZC 115.07(5) | |
| Side setback | 5 ft KZC 20.30.070; KZC 115.07(5) | |
| Rear setback | 10 ft KZC 20.30.070; KZC 115.07(5) | |
| Maximum height | 25 ft KZC 20.30.070; KZC 115.07(5) | |
| Minimum parking | 0 spaces per unit KZC 105.22(1)(b)(2) | |
| Maximum unit size | 1,200 sq ft KZC 115.07(4) | |
| Attached to the main house | Not required KZC 115.07(5) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Planned Unit Development KZC 125.10 | H | — | Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1) | Minimum lot size Not set KZC 125.25; 125.30 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Property is within the jurisdiction of the Shoreline Management Act regulated under Chapter 83 KZC
- Property has a Goat Hill (GH) Overlay
- Lot could develop six or more units under the base zone
- Lot is within a quarter-mile walking distance of a major transit stop
- None of these is true:
- Lot is within a quarter-mile walking distance of a major transit stop
- Any of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- Any of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit