Sign in

PLA 17 · PLA 17 planned area

Kirkland, WA · KZC 20 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Dwelling Unit
Home✓ ADU✓
————
Detached, Attached, or Stacked Dwelling Units—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Middle Housing—
Home✓1 ADU✓1
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Assisted Living Facility————
HomeH ADU—
Co-Living Housing————
HomeH2 ADU—
Convalescent Center————
HomeH ADU—
Nursing Home————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set KZC 20.30.060
  • 6 units3 KZC 113.25; 20.20 PU-24
  • 4 units4 KZC 113.25; 20.20 PU-24
for Middle Housing (4+ units)1
Minimum unitsNot set KZC 20.30.060
No limit KZC 113.25
for Middle Housing (4+ units)1
Minimum lot size2 × 43,560 sq ft KZC 20.30.060
7,200 sq ft KZC 20.30.070
for Detached Dwelling Unit (1 unit); Convalescent Center (group living); Nursing Home (group living)
No limit KZC 113.25
for Middle Housing (2, 3, 4+ units)1
Minimum densityNot set KZC 20.30.070
Medium and high-density zones have a minimum density that is 80 percent of the maximum allowed density. Middle housing projects must provide no fewer than the minimum number of units established by the base zoning before this chapter’s density calculations are applied. KZC 113.25
for Middle Housing (2, 3, 4+ units)1
Maximum densityNot set KZC 20.30.070
1 unit per 3,600 sq ft KZC 20.30.060
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units)
A development more than a quarter-mile walking distance of a major transit stop may have the greater of: Four units per lot; or Twice the maximum number of Detached Dwelling Units allowed in the residential zones. KZC 113.25
for Middle Housing (2, 3, 4+ units)1
Maximum sleeping unitsNot set KZC 20.30.050
2 × (lot area ÷ 3,600, rounded down) sleeping units KZC 20.30 DD-1; 20.30.060
for Assisted Living Facility (group living)
4 × (lot area ÷ 3,600, rounded down) sleeping units KZC 20.30.060; 111.25(1)
for Co-Living Housing (group living)2

3. Building standards

StandardValueExceptions
Front setback20 ft KZC 20.30.070
Side setback5 ft KZC 20.30.070
10 ft KZC 20.30.050
for Convalescent Center (group living); Nursing Home (group living)
Total side setbacksNot set KZC 20.30.070
15 ft KZC 20.30 DD-33
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units); Assisted Living Facility (group living); Co-Living Housing (group living)2
Street side setbackNot set KZC 20.30.070
5 ft KZC 113.25
for Middle Housing (2, 3, 4+ units)1
Rear setback10 ft KZC 20.30.070
Maximum height30 ft KZC 20.30.070
Maximum lot coverage60% KZC 20.30.070
70% KZC 20.30.050
for Convalescent Center (group living); Nursing Home (group living)
Minimum parking
  • 0 spaces per unit5 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit6 KZC 105.22(2)(a)(2)
  • 0 spaces per unit5 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 1 space per unit6 KZC 105.22(2)(a)(1)
for Detached Dwelling Unit (1 unit)
0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living)
  • 0 spaces per unit7 KZC 111.25(2)(a); 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit8 KZC 105.22(2)(a)(2)
for Co-Living Housing (group living)2
1 space per bed KZC 20.40.050
for Convalescent Center (group living)
0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living)
Maximum unit sizeNot set KZC 20.30.070
800 square feet for Carriage Units, 1,700 square feet for Cottage units KZC 113.25
for Middle Housing (2, 3, 4+ units)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units KZC 115.07

Building

StandardValueExceptions
Front setback20 ft KZC 20.30.070; KZC 115.07(5)
Side setback5 ft KZC 20.30.070; KZC 115.07(5)
Rear setback10 ft KZC 20.30.070; KZC 115.07(5)
Maximum height30 ft KZC 20.30.070; KZC 115.07(5)
Minimum parking0 spaces per unit KZC 105.22(1)(b)(2)
Maximum unit size1,200 sq ft KZC 115.07(4)
Attached to the main houseNot required KZC 115.07(5)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Planned Unit Development KZC 125.10 H — Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1)
Minimum lot size
Not set KZC 125.25; 125.30

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Property is within the jurisdiction of the Shoreline Management Act regulated under Chapter 83 KZC
    • Property has a Goat Hill (GH) Overlay
  2. Lot could develop six or more units under the base zone
  3. Lot is within a quarter-mile walking distance of a major transit stop
  4. None of these is true:
    • Lot is within a quarter-mile walking distance of a major transit stop
  5. Any of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  6. None of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  7. Any of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit
  8. None of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit