PLA 6B · PLA 6B planned area

Kirkland, WA · KZC 30 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Dwelling Unit
Home✓ ADU✓
————
Detached, Attached, or Stacked Dwelling Units—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Development Containing Stacked or Attached Dwelling Units and Office Uses—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Assisted Living Facility————
Home✓ ADU—
Co-Living Housing————
Home✓2 ADU—
Convalescent Center————
HomeA ADU—
Nursing Home————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size3,600 sq ft KZC 30.30.070
7,200 sq ft KZC 30.30.050
for Convalescent Center (group living); Nursing Home (group living)
Maximum density1 unit per 3,600 sq ft KZC 30.30.060
Not set KZC 30.30.070
for Detached Dwelling Unit (1 unit); Assisted Living Facility (group living); Co-Living Housing (group living)2; Convalescent Center (group living); Nursing Home (group living)
Maximum sleeping unitsNot set KZC 30.30.050
2 × (lot area ÷ 3,600, rounded down) sleeping units KZC 30.30.010; 30.30.060
for Assisted Living Facility (group living)
4 × (lot area ÷ 3,600, rounded down) sleeping units KZC 30.30.060; 111.25(1)
for Co-Living Housing (group living)2

3. Building standards

StandardValueExceptions
Front setback20 ft KZC 30.30.070
Side setback
  • 0 ft3 KZC 30.30 DD-10
  • 5 ft4 KZC 30.30.060
5 ft KZC 30.30.070
for Detached Dwelling Unit (1 unit); Assisted Living Facility (group living)
10 ft KZC 30.30.050
for Convalescent Center (group living); Nursing Home (group living)
Total side setbacks15 ft KZC 30.30 DD-3
Not set KZC 30.30.070
for Detached Dwelling Unit (1 unit); Convalescent Center (group living); Nursing Home (group living)
Rear setback
  • 0 ft5 KZC 30.30 DD-11
  • 10 ft6 KZC 30.30.060
10 ft KZC 30.30.070
for Detached Dwelling Unit (1 unit); Assisted Living Facility (group living); Convalescent Center (group living); Nursing Home (group living)
Maximum height
  • 25 ft7 KZC 30.30.070; KZC 30.30 DD-9
  • 30 ft8 KZC 30.30.070
  • 30 ft9 KZC 30.30 DD-22
  • 25 ft10 KZC 30.30.010; KZC 30.30 DD-9
  • 30 ft8 KZC 30.30.010
for Assisted Living Facility (group living); Convalescent Center (group living); Nursing Home (group living)
Maximum lot coverage70% KZC 30.30.070
Minimum parking
  • 0 spaces per unit11 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit12 KZC 105.22(2)(a)(2)
  • 0 spaces per unit11 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 1 space per unit12 KZC 105.22(2)(a)(1)
for Detached Dwelling Unit (1 unit)
0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living)
  • 0 spaces per unit13 KZC 111.25(2)(a); 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit14 KZC 105.22(2)(a)(2)
for Co-Living Housing (group living)2
1 space per bed KZC 30.40.050
for Convalescent Center (group living)
0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units KZC 115.07

Building

StandardValueExceptions
Front setback20 ft KZC 30.30.070; KZC 115.07(5)
Side setback5 ft KZC 30.30.070; KZC 115.07(5)
Rear setback10 ft KZC 30.30.070; KZC 115.07(5)
Maximum height
  • 25 ft7 KZC 30.30.070; KZC 115.07(5); KZC 30.30 DD-9
  • 30 ft8 KZC 30.30.070; KZC 115.07(5)
  • 30 ft9 KZC 30.30 DD-22
Minimum parking0 spaces per unit KZC 105.22(1)(b)(2)
Maximum unit size1,200 sq ft KZC 115.07(4)
Attached to the main houseNot required KZC 115.07(5)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Planned Unit Development KZC 125.10 H — Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1)
Minimum lot size
Not set KZC 125.25; 125.30

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The development contains office uses together with the dwelling units
  2. Lot could develop six or more units under the base zone
  3. The side of the dwelling unit is attached to a dwelling unit on an adjoining lot
  4. None of these is true:
    • The side of the dwelling unit is attached to a dwelling unit on an adjoining lot
  5. The rear of the dwelling unit is attached to a dwelling unit on an adjoining lot
  6. None of these is true:
    • The rear of the dwelling unit is attached to a dwelling unit on an adjoining lot
  7. All of these are true:
    • Subject property adjoins a low density zone other than RSX
    None of these is true:
    • The adjoining low density zone is occupied by a school allowed to increase its height to at least 30 feet
  8. None of these is true:
    • Subject property adjoins a low density zone other than RSX
  9. All of these are true:
    • Subject property adjoins a low density zone other than RSX
    • The adjoining low density zone is occupied by a school allowed to increase its height to at least 30 feet
  10. Subject property adjoins a low density zone other than RSX
  11. Any of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  12. None of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  13. Any of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit
  14. None of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit