Sign in

MVLR · Manchester Village Low Residential

Kitsap County, WA · KCC 17.360B · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached (includes manufactured homes)
Home✓ ADU✓1 ✓2
————
Duplex—
Home✓ ADU✓1 ✓2
———
Single-family attached—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Adult family home————
Home✓ ADU✓1 ✓2
Group living————
HomeH3 ADU—
Permanent transitory accommodations, small, large, safe parks, and indoor————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size21,780 sq ft KCC 17.420.056; 17.420.060(A)(12)
Minimum lot width60 ft KCC 17.420.056; 17.420.060(A)(12)
Minimum lot depth60 ft KCC 17.420.056; 17.420.060(A)(12)
Minimum densityNo limit KCC 17.420.056; 17.420.040
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)3
Maximum density2 units per acre, a fraction of 0.5 or more rounds up KCC 17.420.056; 17.420.060(A)(15); 17.420.020(A)
Not set KCC 17.420.056
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)3
Maximum residents“Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045
Not set KCC 17.415.250
for Group living (group living)3
  • 25 persons4 KCC 17.505.040(B)
  • 50 persons5 KCC 17.505.040(C)
  • 25 persons6 KCC 17.505.040(D)
  • 75 persons7 KCC 17.505.040(E)
for Permanent transitory accommodations, small, large, safe parks, and indoor (group living)

3. Building standards

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.8 KCC 17.420.060(A)(41)
  • 20 ft9 KCC 17.420.056
20 ft KCC 17.420.056
for Group living (group living)3; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum front setbackNo limit KCC 17.420.056; 17.420.040
Side setback5 ft KCC 17.420.056
Rear setback5 ft KCC 17.420.056
Maximum height
  • 28 ft10 KCC 17.420.056; 17.420.060(A)(14)
  • 35 ft11 KCC 17.420.056; 17.420.060(A)(14)
Maximum lot coverageNo limit KCC 17.420.056; 17.420.040
Maximum impervious surface
  • 50%12 KCC 17.420.056; 17.420.060(A)(16)
  • 40%13 KCC 17.420.056; 17.420.060(A)(16)
Minimum parking2 spaces per unit KCC 17.490.030
Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Adult family home (group living); Group living (group living)3; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum lot sizeNo limit KCC 17.420.056; 17.420.040

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit KCC 17.415.015(A)(4); 17.415.015(A)(6)

Building

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.8 KCC 17.420.060(A)(41)
  • 20 ft9 KCC 17.420.056
Side setback5 ft KCC 17.420.056
Rear setback5 ft KCC 17.420.056
Maximum height
  • 28 ft10 KCC 17.420.056; 17.420.060(A)(14)
  • 35 ft11 KCC 17.420.056; 17.420.060(A)(14)
Minimum parking1 space per unit KCC 17.415.015(A)(5); 17.490.030
Maximum unit size0.5 × floor area of the main house sq ft KCC 17.415.015(A)(2)
the smallest of 0.5 × floor area of the main house, 900 sq ft KCC 17.415.015(B)(3)
for Single-family detached (includes manufactured homes) (1 unit)2; Duplex (2 units)2; Single-family attached (2, 3, 4+ units)2; Adult family home (group living)2
Attached to the main houseRequired KCC 17.415.015(A)(1); 17.110.017
Not required KCC 17.415.015(B); 17.110.020
for Single-family detached (includes manufactured homes) (1 unit)2; Duplex (2 units)2; Single-family attached (2, 3, 4+ units)2; Adult family home (group living)2
Owner lives on siteRequired KCC 17.415.015(A)(1)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision KCC 16.48.020 A up to 4 KCC 16.10.320(B) —
Minimum lot size
21,780 sq ft KCC 17.420.056; 17.420.060(A)(12)
Minimum lot width
60 ft KCC 17.420.056; 17.420.060(A)(12)
Minimum lot depth
60 ft KCC 17.420.056; 17.420.060(A)(12)
Subdivision KCC 16.40.030 H 5 or more KCC 16.10.340 —
Minimum lot size
21,780 sq ft KCC 17.420.056; 17.420.060(A)(12)
Minimum lot width
60 ft KCC 17.420.056; 17.420.060(A)(12)
Minimum lot depth
60 ft KCC 17.420.056; 17.420.060(A)(12)
Binding site plan KCC 16.56.040 A14
Minimum lots
Not set KCC 16.56
—
Minimum lot size
21,780 sq ft KCC 17.420.056; 17.420.060(A)(12); 16.56.030(A)
Minimum lot width
60 ft KCC 17.420.056; 17.420.060(A)(12); 16.56.030(A)
Minimum lot depth
60 ft KCC 17.420.056; 17.420.060(A)(12); 16.56.030(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
  2. The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
  3. Sleeping units in the project is at most 6
  4. Type of transitory accommodation is small
  5. Type of transitory accommodation is large
  6. Type of transitory accommodation is safe_park
  7. Type of transitory accommodation is indoor
  8. One or both abutting lots have dwellings with front yards less than the required depth
  9. None of these is true:
    • One or both abutting lots have dwellings with front yards less than the required depth
  10. All of these are true:
    • Lot is in the Manchester view protection overlay (Appendix B2)
    None of these is true:
    • There is no existing view of downtown Seattle, the Cascade Mountains, Mt. Rainier or the Puget Sound from the subject property or any adjacent property
    • The owners of all adjacent properties approve the building height prior to building permit issuance
    • It can be explicitly shown that the structure will not cause the blockage of existing views from any of the adjacent properties
  11. Not all of these are true:
    • Lot is in the Manchester view protection overlay (Appendix B2)
    • None of these is true:
      • There is no existing view of downtown Seattle, the Cascade Mountains, Mt. Rainier or the Puget Sound from the subject property or any adjacent property
      • The owners of all adjacent properties approve the building height prior to building permit issuance
      • It can be explicitly shown that the structure will not cause the blockage of existing views from any of the adjacent properties
  12. Lot area is at most 21,780 sf
  13. Lot area is more than 21,780 sf
  14. The land is divided through a condominium process under Chapter 64.32 or 64.34 RCW